PROPERTY DESCRIPTION:
SITE NOTES:
Meter box location
to be verified by builder on site. Lot 114 on RP132135
SC point Note: Driveway profile
UNDERGROUND SERVICES RL 37.57
Garage wall as per Standard Local Govt: Noosa Shire Council
1874 Lwr Wall
S
717 OMP
to be FRL 60/60/60 County of March
1244 OMP
I.L 1100mm Drawing RS-050
2724 Wall
Contact should be made to the relevant RL 36.47
authority for detailed location of all 24.14m 132 30'
MB Parish of Weyba
1787
underground services prior to any demolition,
1600
OMP
excavation or construction on this site.
120
0 1
5622 Proposed 5 Ventura St Sunrise Beach Qld
PROPERTY BOUNDARIES OMP driveway- Exposed
584
AREA: 705.62 m2
6102
Lwr House walls Aggregate - to 50m2
OM
Verify all bearing and dimensions on site prior P 12
28
to any construction. 6599
line
Solar PROPOSED Wall
SITE COVER: 263.83m2 - 37.39%
''
3'40
hes
SITE PREPARATION
LB
DWELLING 1
VENTURA
Panels
HW
Clot
All adjoining external 272
61 4
SITE PREPARATION - CLEAR VEGETATION FOLLOWED PAD HEIGHT
Fascias
BY EXCAVATION OF TOP SOIL AND MATERIAL TO SUIT walls to comply with
RL 37.5
203
937 Fascias
1231 Fascias
FINAL DESIGN LEVELS. NCC Vol 2 2019 1 4 x 3m 25m2 tiling
CUT AND FILL BATTENS NOT TO EXCEED A MAXIMUM Part 3.7.2 - Fire Wa Pool
SLOPE AS PER BCA TABLE 3.1.1.1 FOR THE SITE ll around pool
separation of
1201
SPECIFIC SOIL. including coping
external walls and 678
HW
SURFACE WATER Part 3.7.2.4 - Construction 329
of external walls and 8
218 00'
DIRECT ALL SURFACE WATER AWAY FROM OMP
min FRL 60/60/60. 5517
ST
ADJOINING BUILDINGS AND NEW BUILDING.
MBClothesline
GROUND SURFACE TO BE SLOPED MIN 1:20 Roofing, fascia, gutter & OMP
AWAY FROM BUILDINGS FOR 900mm MIN AND eaves lining to be of
TO A POINT THAT AVOIDS PONDING NEAR
PROPOSED 6510 Wall
non combustible DWELLING 2
19.215m
BUILDING.
materials.
STORMWATER PAD HEIGHT
RL 37.40
ROOF WATER TO STREET KERB OR Pool by
94m
owner
TO COUNCIL APPROVED SYSTEM. H
Wall
RT
23.4
ALL DOWNPIPES TO BE 90mm DIAMETER Proposed OS
O
2.989m
5716
6750
2'
TO STORMWATER PIPES IN ACCORDANCE driveway -
OMP
N
234 0
6138
WITH A.S. 3500.3 & TO DISPURSE 125m2 MAX Exposed
Wall
ROOF AREA Aggregate-
4741
Wall
T
3948
3810
5098
OMP
to 70m2
OMP
9.053
Wa
PLUMBING m
6 9m
WM
ll
'
26 .98
07
PLUMBING LAYOUT DIAGRAMMATICAL 326 4 LB
3'30''
2
ONLY. LICENCED PLUMBER TO CONFIRM T W 19.063m 9m
ALL PLUMBING AND VENTING ON SITE. 314 14'30'' 2 .9 8 2 '
1
298
PLUMBER & DRAINER INSTALLATION TO COMPLY PP Note: Driveway profile W W PP LEGEND
WITH THE STANDARD PLUMBING & DRAINAGE as per Standard W
REGULATION 2003. Drawing RS-050
- PEG
SEWERAGE
HW - HOT WATER
SEWERAGE TO DISCHARGE TO SEWER MAIN - METER BOX
MB
OR ON SITE TREATMENT (TO ENGINEERS DESIGN)
AND TO COUNCIL REQUIREMENTS.
MARGIT CRES W - WATER MAIN
WM - WATER METER
SITE PLAN S
PP
- SEWER LINE
- OVERHEAD POWER POLE
SOIL CLASS: 'P' SITE SCALE 1:200 LB - LETTER BOX
WIND CLASS: N3 SC - SEWER CONNECTION POINT
T - TELSTRA
OS - OUTDOOR SHOWER
FOR CONSTRUCTION
No. Description Date Tracy Dowden - Building Designer Client: Richard & Jodie Thomas
Site Plan
18/03/2020 3:38:08 PM
22 For Construction WD's Rev 5 10/2/20
QBCC: 1009413 Description Proposed duplex
23 For Construction WD's Rev 6 19/2/20
24 For Construction WD's Rev 7 23/2/20 Project number 5VEN
25
26
For Construction WD's Rev 8
For Construction WD's Rev 9
26/2/20
15/3/20
Site Address: 5 Ventura St