GENERAL NOTES STRUCTURAL DESIGN WINDOWS
ALL DIMENSIONS IN MILLIMETRES. ALUMINIUM & GLAZING IN ACCORDANCE WITH
WHERE A STRUCTURAL ENGINEER HAS BEEN CONSULTED A.S. 2047 - 2014 - WINDOWS IN BUILDINGS.
ALL TIMBER OR STEEL FRAMED WALLS TO WET AREAS TO BE - ENGINEER'S DRAWINGS AND SPECIFICATIONS TO BE TO SUIT SITE DESIGN WIND LOADING.
LINED WITH FC OR APPROVED WET AREA CLADDING, FIXED STRICTLY COMPLIED WITH.
IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. RETAINING STRUCTURES PROTECTION OF OPENABLE WINDOWS TO COMPLY WITH
NCC VOL 2 2019 PART 3.9.2.6 AND PART 3.9.2.7.
SUPSPENDED TIMBER OR STEEL FRAMED FLOORS TO HAVE WET 1. DO NOT BACKFILL RETAINING WALLS UNTIL WINDOWS TO BE PROTECTED IN BEDROOMS
AREA FLOORING TO ALL WET AREAS, FIXED IN ACCORDANCE 21 DAYS AFTER CONCRETE HAS BEEN PLACED WHERE WINDOW IS 2M OR MORE ABOVE THE SURFACE
WITH MANUFACTURER'S SPECIFICATIONS. IN THE WALLS OF THE RETAINING BENEATH AND OTHER ROOMS WINDOWS WHERE WINDOW
STRUCTURES UNLESS NOTED OTHERWISE. IS 4M OR MORE ABOVE SURFACE BENEATH.
THE SUB-FLOOR SPACE OF A DWELLING MUST BE VENTILATED IN 2. THE BACKFILL MATERIAL BEHIND THE FULL
ACCORDANCE WITH NCC VOL 2 2019 PART 3.4.1 LENGTH OF THE EARTH RETAINING WALLS
SHALL CONSIST OF A COARSE GRAINED SOIL
LININGS
ALL GLAZING TO COMPLY WITH NCC VOL 2 2019 PART 3.6 AND MUST BE OF HIGH PERMEABILITY (ie CLEAN COURSE
DESIGNED FOR THE WIND LOADS SPECIFIC TO THE BUILDING. EXTERNAL CLADDINGS AND INTERNAL LININGS
SAND OR GRAVEL) TO MAX WIDTH OF 300MM
TO BE FIXED AND FINISHED IN ACCORDANCE
FOR THE FULL RETAINING HEIGHT.
SMOKE ALARMS MUST BE INSTALLED IN ACCORDANCE WITH NCC VOL 2 2019 WITH MANUFACTURER'S SPECIFICATION.
PART 3.7.5, BE MAINS AND INTERCONNECTED AND COMPLY WITH AS3786
WET AREA SURFACES BRICKWORK
WATER CLOSETS (WC'S) TO HAVE A MINIMUM CLEAR WIDTH OF 900MM
FLOOR SURFACES TO BATH & LAUNDRY SHALL BE IMPERVIOUS, BRICKWORK TO BE IN ACCORDANCE WITH AS1225.
DOORS TO WC'S WHICH SWING 'IN' ARE TO HAVE LIFT - OFF HINGES. WITH JUNCTIONS BETWEEN WALL AND FLOOR FLASHED TO DPC TO BE INSTALLED 150mm ABOVE GROUND.
PROVIDE ADEQUATE CLEARANCE AT TOP OF DOOR TO SUIT HINGES. PREVENT MOISTURE PENETRATION INTO WALLS. WALLS TO HAVE A CONTINUOUS CAVITY KEPT
CLEAN OF MORTAR DROPPINGS. ALL OPENINGS TO BE
ALL OTHER CONNECTIONS TO BE IN ACCORDANCE WITH A.S. A1684.2 TIMBER CERAMIC TILES OR OTHER APPROVED IMPERVIOUS MATERIAL FULLY FLASHED WITH STANDARD DPC MATERIAL TO
FRAMING CODE. TO WALLS ABOVE SHOWERS TO 1800MM MIN ABOVE FLOOR. PREVENT WATER PENETRATION TO INTERNAL AREAS.
BRICK ARTICULATION/EXPANSION JOINTS TO ENGINEER
STAIRS SHALL BE DESIGNED IN ACCORDANCE WITH NCC VOL 2 2019 PART 3.9.1. SUSTAINABLE BUILDING NOTES: DETAILS.
RISERS (R) - 115MIN, 190 MAX MP 4.1 - ACCEPTABLE SOLUTIONS
GOINGS (G) - 240 MIN (Class 1 &10), 355 MAX; TERMITES
2R+G = 550 MIN, 700 MAX 1. HOME ADDITIONS TO HAVE ENERGY EFFICIENT LIGHTING
MAXIMUM OPENING = 125 mm FOR A MINIMUM OF 80% OF TOTAL FIXED INTERNAL LIGHTING. A TERMITE MANAGEMENT SYSTEM MUST BE INSTALLED IN
2. HOME ADDITIONS TO HAVE NEW AIRCONDITIONERS WITH ACCORDANCE WITH NCC VOL 2 2019 PART 3.1.4 & AS3660
STAIR TREADS MUST HAVE A SLIP RESISTANT FINISH OR A SUITABLE NON AN E.E.R OF 2.9 MIN. - TERMITE MANAGEMENT FOR A SLAB CONFORMING WITH
SKID STRIP NEAR THE EDGE OF THE NOSINGS IN ACCORDANCE WITH 3. HOME ADDITIONS TO HAVE ALL SHOWER ROSES AND TAPS AS2870 - RESIDENTIAL SLABS & FOOTINGS - CONSTRUCTION.
NCC VOL 2 2019 PART 3.9.1.4. SERVING LAUNDRY TUBS, KITCHEN SINKS AND BASINS WITH
A MIN 3 STAR WATER EFFICIENCY LABELLING AND STANDARDS TERMITE BARRIERS MUST BE INSTALLED IN ACCORDANCE
ALL BALUSTRADES AND HANDRAILS TO BE 1000 MIN ABOVE FINISHED RATING. ALL TOILET CISTERNS TO HAVE A DUAL FLUSH WITH MANUFACTURERS RECOMMENDATIONS OR BY AN
FLOOR LEVEL, 865mm MIN ABOVE STAIR NOSINGS AND HAVE NO OPENINGS SYSTEM AND A MIN 4 STAR WATER EFFICIENCY LABELLING AND ACCREDITED TECHNICIAN.
GREATER THAN 125mm, IN ACCORDANCE WITH NCC VOL 2 2019 PART 3.9.2 STANDARDS RATING.
BUSHFIRE HAZARD AREAS
ALL LAMINATED TIMBER BEAMS TO HAVE FULL-WIDTH BEARING AT OTHER
EACH END UNLESS OTHERWISE NOTED BY MANUFACTURERS BUSHFIRE HAZARD AREAS ARE TO COMPLY WITH AS3959 &
SPECIFICATION REQUIREMENTS. VEHICLE CROSS OVERS SHALL COMPLY WITH LOCAL NCC VOL 2 2019 - PART 2.3 & 3.7
AUTHORITY REQUIREMENTS.
CONCRETE MASONRY DESIGN TO AS 3700.
FIRE & ACOUSTIC SEPARATION
WRITTEN DIMENSIONS TO HAVE PREFERENCE OVER SCALED
DIMENSIONS BUILT TO BOUNDARY WALLS & SEPARATING WALLS
BETWEEN TWO OR MORE CLASS 1 BUILDINGS MUST BE IN ACCORDANCE
ALL ASPECTS OF THIS PROJECT TO COMPLY WITH THE WORK WITH NCC VOL 2 2019 - PART 3.7 FIRE SAFETY
HEALTH AND SAFETY ACT 2011 & AS AMENDED. AND PART 3.8.6 - SOUND INSULATION.
IT IS AT THE BUILDERS DISCRETION TO POSITION BULKHEADS OR SERVICE
PANELS UNDER FLOOR FRAMING TO ACCOMODATE PLUMBING SERVICES.
FOR CONSTRUCTION
No. Description Date Tracy Dowden - Building Designer Client: Richard & Jodie Thomas
Detail Notes
18/03/2020 3:38:22 PM
22 For Construction WD's Rev 5 10/2/20
QBCC: 1009413 Description Proposed duplex
23 For Construction WD's Rev 6 19/2/20
24 For Construction WD's Rev 7 23/2/20 Project number 5VEN
25
26
For Construction WD's Rev 8
For Construction WD's Rev 9
26/2/20
15/3/20
Site Address: 5 Ventura St
Sunrise Beach Qld
Date 22/4/19 A133
Drawn by T.D
27 For Construction WD's Rev 10 18/3/20
QBCC Lic 1184982 Checked by T.D Scale 1 : 100
THIS DESIGN REMAINS THE COPYRIGHT OF THE DESIGNER.