Original source · versioned page text
Reps - Revised plans
Plans and drawings: the text below has words only, no drawings.
Original PDF page 30, section 1. The text section number identifies this passage in the reader.
LEGEND - Villa 1
QUEENSLAND SMOKE ALARM SYMBOL ITEM NO. OF
REQUIREMENTS AS OF 1/1/17 S Smoke Alarm 7
Smoke alarm devices must not be:
In Summary: * within 300mm of a light fitting MB Meter Box 1
* if installed on a ceiling, within 300mm of a corner of the ceiling and wall GAS Gas Bottle 0
Smoke alarm devices must be installed: * if installed in a staiwell, out of reach of smoke because of an obstruction
* within 400mm of an opening from which air supplied from an air conditioner DW Dishwasher 1
* If practicable, on the ceiling - if the ceiling slopes, it must be in an area of the ceiling that is or force air ventilation within 400mm of the blades of a ceiling fan HW Hotwater 1
between 500mm and 1500mm from the apex of the ceiling. Down light - LED 39
* If installing on the ceiling is not practicable, on an exposed joist or beam that when
measured from the ceiling does not have a depth of more than 300mm when measured Ceiling Fan 6
from the ceiling. Ceiling Fan/light 0
* If these two placements are not practicable, the device can be installed on a wall in an
area that is between 100mm and 300mm from the ceiling and more than 300mm from D Data Point 2
the corner of 2 walls.
PH Phone Point 1
MB TV TV Point 2
HL Exhaust Fan Heat lamp 1
AB - ABOVE BENCH Exhaust Fan/light 2
UB - UNDER BENCH
WP Water proof Dbl PP 2
PH
P Pendant Light- Client supply 1
Double Power Point 26
1400h
D TV
GDO
Single Power Point 3
2W Two way 1
DN S
3000 LED Strip 0
AB UB
S
Spot light 0
Double spotlight w sensr 2
Wall light 0
HW
S DN
NBN PP Pool Pump Power 1
A/C Airconditioner - Ducted 1
AC
P
4000
2w
PL GDO Garage Door Opener 1
ay
S POOL
DB WO Wall oven 1
T MW Microwave Single GPO 1
RH Rangehood Single GPO 1
GROUND FLOOR - Villa 1 PP
CT Cooktop - Induction 1
NBN Broadband Connection 1
ELECTRICAL LAYOUT SWP Single Waterproof PP 0
SCALE 1:100 USB USB Point with GPO 1
PL Pool light 1
Single Fluro batten light 2
Niche Star light 0
6.6Kw Solar system 1
Stair wall light 0
S/S up/down light 2
FOR CONSTRUCTION DB Door bell 1
No. Description Date Tracy Dowden - Building Designer Client: Richard & Jodie Thomas
G.F. Electrical Plan Villa 1
18/03/2020 3:38:23 PM
22 For Construction WD's Rev 5 10/2/20
QBCC: 1009413 Description Proposed duplex
23 For Construction WD's Rev 6 19/2/20
24 For Construction WD's Rev 7 23/2/20 Project number 5VEN
25
26
For Construction WD's Rev 8
For Construction WD's Rev 9
26/2/20
15/3/20
Site Address: 5 Ventura St
Sunrise Beach Qld
Date 22/4/19 A136
Drawn by T.D
27 For Construction WD's Rev 10 18/3/20
QBCC Lic 1184982 Checked by T.D Scale As indicated
THIS DESIGN REMAINS THE COPYRIGHT OF THE DESIGNER.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original