rev date issued details
Working Drawings
A 28.10.19 NV Building Approval
ROOF ROOF SKIRTING TILES
RFS-01 New Metal Sheet Roof RFS-05 Concrete Roof SKT-02 Skirting T-01 Tile Type 1
Framed roof as Engineers Drawings with Poured concrete roof as Engineers Powder coated Flat plate aluminium Stone tiles laid in combination pattern as
metal sheet roofing to pitch indicated on Drawings. Set-out and detail as per Dimensions: 92x3mm (laundry) indicated- set out to be confirmed on site.
Architects Drawings . Architects Drawing. 42x3mm (office)
Flashings and capping as required, Type: Fallow granite - Eco Outdoor
concealed fixings generally: MTL-03 Smooth face formwork. Square edges Finish: PT-07 Size 1:600x300mm
with no fillets generally. V drip groove to Size 2: 400x300mm
Sheeting: Custom Orb 0.48 base metal all external soffit edges. Reinforcing as STAIRS Colour: Natural
thickness (BMT) roof sheeting. Install to per engineers specifications. Fully Finish: Exfoliated - Water and UV resistant
manufacturers specifications.MTL-03 tanked and set to fall as req. STA-01 New Stair clear matt penetrating sealer to
manufacturers specifications.
Type: Permalite Finish:REN-01 New cast in-situ concrete stairs refer to
Colour: To march surfmist Engineer’s Drawings. Mitred junctions generally. Setout to be
Hob Spitters: SP-01 (refer to plumbing confirmed with Architect prior to laying.
schedule, confirm set-out with architect) Refer to stair detail drawings for set-out.
Gutters: Custom folded to match. Allow for 100mm mitred downturn tile
Allow for Mesh leaf guard.MTL-03 Pebbles: PBL-01 Finish to treads, risers and exposed faces: edges to slabs, (where visible) unless
T-01 noted otherwise.
Refer to landscape Architects drawings Contrast strip to treads: T-02
Downpipes: Double DP-01 with custom for roof garden details. Grout Colour: to match stage 1
folded rainwater heads with overflow slot Allow for custom handrails both sides:
MTL-03 Refer to Plumbing Schedule for drainage HR-01 T-02 Tile Type 2
details.
Allow for TGSI indicator (dots). Top and Contrast strip
RFS-02 New Concrete Roof SCREENS bottom. 316 Stainless steel.
50mm contrast stone strip to all treads and
SCN-01 Fixed Vertical Trellis Screen Must comply with NCC and landings for STA-01 :
Poured concrete roof as Engineers
Drawings. Set-out and detail as per AS1428.1-2009 requirements
Vertical tensioned stainless steel cables, Type: Raven granite - Eco Outdoor
Architects Drawing. 450mm ctrs. Pin fixed hubs 100mm as STRUCTURE
req. Set-out to be confirm with Architect. T-03 Tile Type 3
Smooth face formwork. Square edges STR-01 Concrete Column
with no fillets generally. V drip groove to Mitred junctions generally. Setout to be
All fixings, cables, tensioners and hubs to
all external soffit edges.Fully tanked and New cast-insitu concrete column as per confirmed with Architect prior to laying.
be 316 stainless steel.
set to fall as req. Engineer’s Drawings.
SCN-02 Fixed Trellis Screen Type: Matt Black Ceramic
Finish: REN-01 Finish: REN-03 Size: 300x75mm
Soffit: SOF-01 Horizontal tensioned stainless steel Grout: Black
cables, 150mm ctrs generally. Pin fixed STR-02 Arbour Steel Frame
RFS-03 New Walkway Arbour T-04 Tile Type 4
hubs 100mm length. Quantity as req. Set-
out to be confirm with Architect. Frame, refer to Architecture Detail
Timber batten pergola WD-01 Drawings for setout, refer to Engineer’s Mitred junctions generally. Setout to be
combination battens (65mm x 42mm and Drawings for details. confirmed with Architect prior to laying.
All fixings, cables, tensioners and hubs to
42mm x 42mm @ 75mm eq ctrs) fixed to
be 316 stainless steel.
substructure 42mm x 42mm battens Finish: PT-08 Type: Matt White Ceramic
over, Refer to architectural drawings for SCN-03 Aluminium Vertical Batten Screen Size: 300x75mm
detail and set-out. STR-03 Screen Aluminium Frame
Grout: Colour TBC
Aluminium sections combination profiles
Type: WD-01 (32x32 and 32x60). Allow for Aluminium 125x40 RHS aluminium frame
Fixings: 316 SS square drive fixings SHS framing behind. Fixings, to be 316 powder coated, pinned to existing block FIRE PROTECTION
Finish: No finish - Weather naturally stainless steel concealed generally. work wall welded into modules and
concealed fixed as required. F.H.R Fire Hose Reel
Substructure set out as per architectural
drawings. Fabricator to confirm sizes and
RFS-04 Concrete Roof Fixings, to be 316 stainless steel with (Relocate existing) As per QFES
locations with architect prior to
construction. rubber washers. requirements, and NCC - Part E1.
Poured concrete roof as Engineers
Drawings. Set-out and detail as per Colour: PT-07 Refer to drawings for locations
Architects Drawing.
Finish: Powdercoat TIMBER F.E Fire Extinguisher
Colour: PT-07
Smooth face formwork. Square edges
WD-01 Dressed Timber (New) As per QFES requirements, and
with no fillets generally. V drip groove to SCN-04 Stainless Steel Fire Proof Screen
NCC - Part E1
all external soffit edges.Fully tanked and
DAR Timber to sizes and shapes shown on Refer to drawings for locations
set to fall as req. Stainless steel woven mesh powdercoated
Architects Drawings. Fixings, to be 316
black Crimsafe frame (concealed fit F.B Fire Blanket
stainless steel generally.
Finish: REN-01, T-03 (refer to drawings window) or similar approved
for extetent, confirm setout and detail Fixings, to be 316 stainless steel. (New) As per QFES requirements, and
Type: Accoya timber (treated with fire
with architect) NCC - Part E1
retardant)
Builder to confirm detail with Architect and
Finish: No finish - weather naturally
Soffit: CLG-03 fire Engineer prior to manufacture. Refer to drawings for locations
WD-02 Shiplap
Hob Spitters: SP-01 (refer to plumbing Finish: Powdercoat
schedule, confirm set-out with architect) Colour: PT-07 Horizontal shiplap profile cladding 145mm
x 15mm. Concealed fixings,to be 316
Refer to landscape Architects drawings stainless steel generally. Where visible face
for roof garden details. SKIRTING
fixings are required use brass rose head
SKT-01 Skirting ‘gripfast’ nails. Confirm with architect if
Refer to Plumbing Schedule for drainage unsure.
details.
Type: Acoya timber (treated with fire
Downpipes: Double DP-01 retardant)
Finish: No finish - weather naturally
Rainwater Heads: Custom folded with
overflow provisions MTL-03
a: suite 6, 8 kingfisher drive, peregian beach, qld 4573
p: (07) 5471 3033 Culgoa Resort Stage 2 - Entry Alteration Scale @A1
sparks architects www.sparksarchitects.com
5 Quamby Pl, Noosa Heads QLD 4567 Culgoa Point Beach Resort 106 NV Materials and Finishes Schedule WD 1.4
sparks architects pty. ltd. abn 89 124 611 721
qld architect's registration No. 3974 project client job no. drawn drawing dwg no.
GSPublisherVersion 443.1.1.0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
4. Architectural Drawings.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.