J H G F E D C B A CODE
GL01
IMAGE / SPECIFICATION
EXTERIOR TOUGHENED GLAZING
EXTERNAL GLAZED SLIDE DOOR AND FIXED DOUBLE FRENCH WINDOWS TO SKYLIGHT TO ROOF TO EXTERNAL GLAZED SLIDE DOORS FOR SKYLIGHT TO ROOF TO ALIGN ON WF01 EXTERIOR TIMBER CLADDING
FLOOR TO CEILING WINDOW FOR ACCESS APARTMENT BATHROOM TO MATCH ALIGN ON BOTH SIDES ACCESS TO VERANDA BOTH SIDES OF ROOF
TIMBER TO MATCH EXISTING PANEL -
TO VERANDA EXISTING FEATURE WINDOWS OF OF ROOF PAINT FINISH TO BE CONFIRMED
HERITAGE BUILDINGS 400
332
WL01 WALL LIGHT
WL01 WL01 WL01 WL01
GL-01 GL-01 GL-01 GL-01 GL-01 GL-01 GL-01
GL-01 GL-01 GL-01 GL-01 900 900 900 900 900 486
1300
WF01 WF01
GL-01 GL-01 GL-01 GL-01 GL-01
WF01
1200
WF01
960
ALL STRUCTURAL FIXINGS
REQUIREMNTS TO BE COORDINATED
WITH ENGINEER. SITE VARIABLES TO
BE CONFIRMED PRIOR TO
CONSTRCUTION
1
EXTERIOR WEST ELEVATION
1 : 50
TIMBER FRAMED SASH
WINDOWS TO REFLECT
EXISTING STYLE OF
HERITAGE BUILDING
APPROVED PLAN
BBQ LOCATION MCU10/2017.01
NOOSA COUNCIL
EXTERNAL GLAZED SLIDE DOOR AND FIXED 12 DECEMBER 2024
FLOOR TO CEILING WINDOW FOR ACCESS
TO VERANDA
WF01
WL01
GL-01 GL-01 GL-01 GL-01
GL-01
NEW TIMBER COLUMNS TO BE MATCH
EXISTING COLUMN STRUCTURE -
ENGINEER TO CONFIRM
REQUIREMENTS FOR EXTENSION
1200 NEW TIMBER PANEL FENCING
SURROUND
ALL STRUCTURAL FIXINGS
REQUIREMENTS TO BE COORDINATED
WITH ENGINEER. SITE VARIABLES TO
BE CONFIRMED PRIOR TO
CONSTRCUTION
TERRAIN INDICATIVE ONLY - SITE
VARIABLES TO BE COORDINATED ON
SITE WITH CONTRACTOR AND
ENGINEER. EXISTING VEGETATION AND
PLANTING TO BE MAINTAINED.
2
EXTERIOR NORTH ELEVATION 3
RAINFOREST 3D VIEW NORTH WEST
1 : 50
CONDITIONS OF USE
1. USE FIGURED DIMENSIONS ONLY. DO NOT SCALE. CHECK ALL
CLIENT PROJECT TITLE
REVISION LIST
DATE ISSUE DESCRIPTION DRAWN CHECKED
DRAWING TITLE 0 1 2 3 4 5m
DIMENSIONS ON SITE PRIOR TO FABRICATION OR SETOUT.
2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE EXTERIOR ELEVATIONS - RAINFOREST LODGE
NATIONAL CONSTRUCTION CODE (BCA), AUSTRALIAN
STANDARDS AND LOCAL REGULATIONS. MICHAEL TOZER HALSE LODGE - RAINFOREST LODGE SCALE @ A2 ISSUE DATE SCALE 1: 100
3. ANY ERRORS FOUND IN THIS DOCUMENTATION SHOULD BE
REPORTED TO COLLECTIVUS IMMEDIATELY. As indicated 01.07.24 STATUS
COPYRIGHT SITE ADDRESS PROJECT NO. STAGE APPROVAL
ALL RIGHTS RESERVED . THIS WORK IS COPYRIGHT AND CANNOT
BE REPRODUCED
OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC,
Project Number DD
REVISION
ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) Halse Lodge DRAWING NO. DRW BY/CHK BY
p. 0423 696 135 WITHOUT THE WRITTEN PERMISSION OF T. BLACK . ANY LICENCE,
EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE 2 Halse Lane,
e. [email protected] WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT
20-01 Author/ Checker
Document Set ID: 23352824 OR IMPLIED AGREEMENT WITH T. BLACK . Noosa Heads QLD 4567 ORIGINAL SHEET SIZE A2 [594mm x 420mm]
Version: 1, Version Date: 15/11/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Approved Plans - MCU10/2017.01 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.