25 April 2023 Lisa Pienaar Noosa Council [email protected] RE: Response to Information Request (MCU22/0197, OPW22/0296, RAL22/0031) Multiple Dwelling Units, Associated Operational Works and Community Title Subdivision situated at 73 Southern Cross Pde, Sunrise Beach Council issued a further information request on 14 December 2022. The following additional information provides a response to Council’s Information Request items: Design Plans 1. Amend the ground floor plan and detail all boundaries and the proposed front, side and rear setbacks as provided for the upper level. 2. Provide a plan detailing the location of the section plans. 3. Provide revised section plans, with no more than 2 sections per page. The section plans should also detail the RLs for all floors, the proposed swimming pool and deck levels and existing ground level and label all rooms. 4. Provide revised plans incorporating additional individual design elements to ensure the development is varied further in design to 75 Southern Cross Parade and the garages and balcony balustrade do not present a contionuous form across the façade. 6. Provide amended plans with floor to ceiling heights of 2.7m. All updates referenced above are incorporated in the revised design plans by Zest, including further variation in presentation to Southern Cross Pde, as demonstrated below. Figure.1 Front façade with changes highlighted.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 4 pages
Page 2
7. Provide amended plans increasing the rear setbacks for the units.
A 4.1m setback is provided to the screens attached to the back bedrooms of unit 1, with
the main wall line setback more than 4.8m. The relevant outcomes seek for a sufficient
setback to allow for landscaping and prevent overlooking into adjoining properties. The
design incorporates screening devices to prevent viewing into the adjoining property.
Large structural buffer landscaping is also proposed around the perimeter of this built form
to ensure adverse impacts to the neighbour are avoided.
It is further noted the surrounding rear setbacks adjoining the site at 2/8 Beacon Ct and
1/71 Southern Cross Pde range between 3.6 to 4.2m, as shown below.
Figure.2 Nearmap image of site with adjoining setbacks.
Figure.3 Realestate photos of unit 2/8 Beacon Ct (setback 3.6m from site) showing
change in level and orientation to the north down the hill. As a result of the changes
in levels and landscaping, the site will not be visible from this adjoining neighbour.
Figure.4 picture of 1/71 Southern Cross parade rear boundary from pool.
Page 2 of 5
Page 3
Figure.5 Proposed design of dual occupancy – Note the 4.2m setback from 1/71
Southern Cross Pde (allowed 1.5-2m).
Figure.6 Large structural buffer landscaping surrounding the unit 1 built form.
Page 3 of 5
Page 4
Landscaping
5. Provide a detailed landscaping plans prepared by a suitably qualified
landscape architect in accordance with the requirements of the PSP2 –
Landscaping, and that incorporate the following:
a. Vegetation with vertical scale to be provide screening/buffering of the
built form when viewed from Southern Cross Parade. This landscape
should be designed such, that a minimum 30% of the built form will
be screened at maturity.
b. Screening vegetation with vertical scale to be provide along the
northern boundary to buffer the built from when viewed from the
north. Ensure planting includes appropriate height screening plants
(minimum 4-5 metres in height at maturity)
c. Relocate the timber slat and masonry wall back within the private
court lawn to allow a meaningful landscape space with a width
capable of screening and softening the development. Particular
reference is to be made to A012.2/P012 in response to the item, in this
regard 2 metres of landscape should be provided adjacent the front
wall.
d. Feature pandanus to be located well within the property boundary to
avoid contact with path users on Southern Cross Parade.
14. Provide additional detail demonstrating the location of the proposed Tuckeroo
street trees. The location of the proposed Tuckeroo street trees must comply
with Council’s setback requirements.
All landscaping changes referenced above are incorporated into the revised landscape
plans drawn by Element Design, including tuckaroos in the road verge, pandanus
relocated and dense screening along the frontage and boundaries.
Engineering
8. Provide additional detail on the proposed driveway and crossover. The detail
must be prepared by a suitably qualified person (RPEQ – Registered
Professional Engineer of Queensland) and include, but not be limited to:
a. a design generally in accordance with RS-049, RS-050 and any associated
addendum;
b. dimensions, levels and grade of the access driveway;
9. Provide additional detail demonstrating how trip hazards will be eliminated
within the road reserve due to the construction of the proposed driveway
crossover. Please note that Council is unlikely to support private retaining
structures within the road reserve. The amended plan must be prepared by a
suitably qualified person (RPEQ – Registered Professional Engineer of
Queensland) and include, but not be limited to:
a. the full extent of the transition to the adjoining areas of verge.
10. Provide amended Vehicle Swept Path Plans demonstrating that vehicles are
able to enter and exit the site without the vehicle body envelope colliding with
any features of the proposed development. The additional detail must be
prepared by a suitably qualified person (RPEQ – Registered Professional
Engineer of Queensland) and include, but not be limited to:
a. adjacent carparks must be occupied when demonstrating how a B99
vehicle can enter and exit the proposed garages.
Page 4 of 5
Page 5
b. provide practical start/end points for vehicles entering/exiting the
proposed garages.
11. Provide sufficient detail to demonstrate that the development achieves
compliance with The Noosa Plan 2020 – Sustainable Building Design Code.
The detail must be prepared by a suitably qualified person (RPEQ – Registered
Professional Engineer of Queensland).
12. Provide a Geotechnical Engineer report demonstrating the proposed works
will have no adverse effects on the existing slope stability conditions of the
subject site or any of the adjoining properties. The report must be prepared
by a suitably qualified person (RPEQ – Registered Professional Engineer of
Queensland) and include construction methodology, foundation
recommendations etc.
13. Provide additional detail demonstrating how the proposed earthworks will not
undermine the structural integrity of adjoining properties.
Please find attached response to the items raised from Recor and Tectonic. Furthermore,
a 3,000Ltr tank is proposed under the driveway with water to be used for gardens in
accordance with the Sustainable Building Code.
----------------------------------------------------------------------------------------------------------------------
Pursuant to the Development Assessment Rules, the applicant has given the assessment
manager the information requested. Please continue with your assessment in accordance
with the DA Rules. If you have any further queries in relation to the above, please do not
hesitate to contact myself.
Regards,
Jack Lewis B.Sc Hons UNSW M.Plan Otago
Planner/Director
Pivotal Perspective Pty Ltd
0406 334 227
Page 5 of 5