Attachment C - Earthworks Plans · MCU22/0051
Plans and drawings: the text below has words only, no drawings.
BULK EARTHWORKS LEGEND
A BULK EARTHWORKS TO UNDERCROFT AREA
C03-101
BULK EARTHWORKS TO LANDSCAPE AREA
BULK EARTHWORKS TO PROPOSED RAMP
BE12.50 PROPOSED BULK EARTHWORKS LEVEL
EX EX12.50 EXISTING SURFACE LEVEL
EX EX 14.
13. 14. 410 DEVELOPMENT SITE BOUNDARY
830 424
EX RW PROPOSED RETAINING WALL - STRUCTURAL DESIGN AT DETAIL
RW BE 165.1 DESIGN
10. 48286
200
FFL VARIES FROM 10.40 TO 14.40 BE EXISTING SERVICES LEGEND
10.
BULK EARTHWORKS LEVEL VARIES
RW
BE 200
RW
10. EXISTING STORMWATER DRAINAGE
200
FROM 10.20 TO 14.20 EXISTING WATER
RW
BE EXISTING UNDERGROUND ELECTRICAL
10.
200
BUIL
BE EXISTING OVERHEAD ELECTRICAL
10.
200 EXISTING TELSTRA
DING
EX
16 .35
6 EXISTING KERB INVERT
ABO
EXISTING FENCE
VE
EXISTING BUILDING
NOTES:
1. EXISTING EXTERNAL STRUCTURES AND TREES SHOWN ON THESE DRAWINGS
B ARE FEATURES EXISTING PRIOR TO ANY SEDIMENT AND DEMOLITION WORKS.
C03-101 2. BULK EARTHWORKS SLOPE TO BE MAXIMUM 1V:2H. CONTRACTOR TO ALLOW FOR
ANY REQUIRED SHORING OR PROTECTION TO EXISTING SERVICES AND/OR
ADJACENT PROPERTIES DURING EXCAVATION FOR PROPOSED BULK
EARTHWORKS AND ANY REQUIRED RETAINING WALLS. CONTRACTOR TO ALLOW
TO REINSTATE OR RECTIFY ANY SERVICES AND/OR ADJACENT PROPERTIES
RW
DAMAGED DURING EXCAVATION FOR PROPOSED BULK EARTHWORKS AND ANY
PROPOSED CARPARK LEVEL RL 10.40
GATEWAY DRIVE
REQUIRED RETAINING WALLS.
BULK EARTHWORK LEVEL RL 10.20 3. 'LEVEL 1' SUPERVISION IS REQUIRED FOR ALL EARTHWORKS OPERATIONS AND
CERTIFICATION IS TO BE PROVIDED BY THE NOMINATED GEOTECHNICAL TESTING
AUTHORITY FOR THE FOLLOWING ITEMS:
- CERTIFICATION THAT ALL GENERAL EARTHWORKS OPERATIONS (ie. STRIPPING
PROOF ROLLING OF SUBGRADE, etc.) HAVE BEEN CARRIED OUT IN
ACCORDANCE WITH THE DRAWINGS AND EARTHWORKS SPECIFICATION.
BE - CERTIFICATION THAT THE CONTROLLED FILL IS SUITABLE FOR SUPPORT OF
10.
200 CONVENTIONAL HIGH LEVEL FOOTINGS AND HAS A MINIMUM BEARING
CAPACITY OF 150kPa.
RW
EX - CERTIFICATION THAT FILL HAS BEEN PLACED AND COMPACTED TO THE
BE BE 14.
10. 10. 135 REQUIRED MINIMUM DENSITY IN ACCORDANCE WITH THE DRAWINGS AND
2 00 2 00 FFL VARIES FROM 10.40 TO 14.40 EARTHWORKS SPECIFICATION.
BULK EARTHWORKS LEVEL VARIES - CERTIFICATION THAT THE QUALITY OF ANY IMPORTED FILL COMPLIES WITH
RW
RW
DRAWINGS AND THE EARTHWORKS SPECIFICATION REQUIREMENTS.
FROM 10.20 TO 14.20 4. CONTRACTOR TO PROVIDE AN EARTHWORKS METHODOLOGY STATEMENT FOR
RW RW
BE EX APPROVAL BY ACOR PRIOR TO COMMENCING WORK ON SITE. THE
10. EX EX 14.
13. 13. 201 METHODOLOGY STATEMENT SHALL DEMONSTRATE THE TREATMENT OF
EX 200 EX
12 570 900
11. .69 EXISTING FILL, SITE TRAFFICABILITY AND INCORPORATION OF REQUIRED
379 3 SEDIMENT AND EROSION WORKS. CONTRACTOR TO ALLOW TO ATTEND AN ON
SITE PRE-START MEETING AND TO EXCAVATE TEST PITS AS REQUIRED TO
RAMP UP DEMONSTRATE THE APPROPRIATENESS OF THE METHODOLOGY STATEMENT.
5. CONTRACTOR TO ENSURE PRESERVATION AND AVOID DISTURBANCE OF
EXISTING SURVEY MARKS.
6. UNLESS NOTED AS AN EXISTING TREE TO BE RETAINED ON ARCHITECTURAL
DRAWINGS REMOVE OFF SITE ALL EXISTING TREES AND ALLOW TO DEEP RIP TO
REMOVE ANY TREE ROOTS.
7. UNLESS NOTED AS AN EXISTING TREE TO BE RETAINED ON ARCHITECTURAL
DRAWINGS CONTRACTOR TO ENGAGE A QUALIFIED ARBORIST TO CUTBACK ALL
FOLIAGE OVERHANGING THE BOUNDARY LINE.
8. THE CONTRACTOR TO ENSURE ALL FIRE ANT CONTROLS OR RESTRICTIONS ON
THIS SITE ASSOCIATED REQUIREMENTS HAVE BEEN COMPLIED WITH.
9. REMOVE ALL EXISTING SERVICES AND PIPES AND CAP AT THE SITE BOUNDARY
PRIOR TO UNDERTAKING EARTHWORKS.
10. REFER TO ARCHITECTURAL DRAWINGS FOR EXISTING BUILDING DEMOLITION
DETAILS.
P:\BR21\br210522 bunnings noosaville\Drawings\CAD\CIV\Drawings\BR210522-C03-001.dwg
SCALE 1:200 @ A1
0 2 4 8 12 16 20 metres ENGINEER'S CERTIFICATION
NAME:
SCALE 1:400 @ A3
RPEQ No: THIS DRAWING IS TO BE
C COPYRIGHT of this design and plan is the property of ACOR Consultants (QLD) Pty Ltd, ACN 126 011 087 ABN 18 126 011 087, all rights reserved. It must not be used, modified, reproduced or SIGNED: PRINTED IN COLOUR NOT FOR CONSTRUCTION
copied wholly or in part without written permission from ACOR Consultants (QLD) Pty Ltd. ACOR Consultants is a trademark licensed to ACOR Consultants (QLD) Pty Ltd by ACOR Consultants Pty Ltd.
This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: Client Architect ACOR Consultants (QLD) Pty Ltd Project Drawing Title
BUNNINGS NOOSAVILLE BULK EARTHWORKS PLAN
North
BUNNINGS GROUP LIMITED ARCHITECT DET/LOGO Level 7, 22 Cordelia Street
South Brisbane QLD 4101
Feb 21, 2023 - 10:37am
T +61 7 3844 5900 Drawn Date Scale A1 Q.A. Check Date
A FOR APPROVAL 21.02.23 JG PK LEVEL 6, 131 LEICHHARDT STREET JG FEB 2023 1:200 SS 15.02.23
Issue Description Date Drawn Approved SPRING HILL QLD 4000 CNR EUMUNDI NOOSA ROAD & GATEWAY DRIVE Designed Project No. Dwg. No. Issue
-1 0 1cm at full size 10cm 20cm PHONE : (07) 3831 5399 ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS NOOSAVILLE QLD 4566 PK BR210522 C03-001 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment C - Earthworks Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.8 MB (small file)
- File type
No other editions are linked here.