UNIT B - F.F. AREAS
First Floor Residence (Exc. Voids) : 55.1m² First Floor Residence (Exc. Voids) : 53.8m²
Balcony : 8.8m² Balcony : 12.1m²
First Floor Total : 63.9m² First Floor Total : 62.0m²
T H
Overall Total : 163.4m² Overall Total : 166.0m² NOR
GENERAL NOTES
The builder is responsible to check all
existing services prior to beginning any
construction.
# Denotes cavity slider to manufactuers
specification, frames containing cavity sliders
to be 90mm minimum U.N.O
Builder to verify all dimensions prior to
beginning construction work.
Face fixed glass balustrade Face fixed glass balustrade
Electric HWS to minimum energy efficiency
regulations.
Void Over
2436 stk Roof
Toilets: minimum 4-star dual flush, as rated
2418 sd
Balcony Face fixed glass balustrade
under the Water Efficiency and Labeling
Feature Screen Over Standards scheme (WELS).
Bed 1 r
4.3m x 3.7m oid Ove
Roof V
Tapware: minimum 3-star WELS rated for
Ra
kitchen sinks, basins and laundry troughs.
Balcony
k
2406 lvr 2406 lvr 2406 lvr
ed
4/2406 lvr
Feature Screen Over
Showerheads: minimum 3-star WELS rated
2406 lvr
robe 2427 stk showerheads.
1206 shutter
Vo
SD
Smoke alarms complying with AS 3786
Ra
id
FRL 60/60/60
ov
ke
ng
to be installed and connected to consumer
er
d
livi
820
Glass Balustrade
0606 lvr
liv i
mains power in accordance with NCC part
er
Ens
robe
Bed 1
ng
ov
3.7.2
2406 lvr
id
2700 Ceiling
Vo
3/1206 shutter 2400 Joinery All electrical appliances and plumbing symbols
3.3m x 3.8m 1506 lvr are diagrammatical. Refer to builders
Glass Balustrade 3/1206 shutter
specification for details all fixtures.
820
3/ 2103 fg
Void
820
820
Seal wet areas in accordance with N.C.C. Vol. 2.
Bed 2 1206 shutter
Part 3.8.1. Slope floor surface towards fw
DN 3.7m x 3.1m
4/1506 lvr
robe (floor wastes)
DN
Provide lighting in accordance with N.C.C. Vol. 2.
Ens Bed 2
0606 lvr
770 cs
Ens Part 3.8.4.2 & 3
770
Ens 3.2m x 3.5m Provide ventilation in accordance with N.C.C.
Vol. 2. Part 3.8.5
robe Mechanical ventilation in accordance with N.C.C
Vol. 2. and AS1668.2
Dimensions Note:
0606 lvr 1806 lvr 0606 lvr
0604 lvr
All wall dimensions are taken from
Roof Below Roof Below the outside faces of the stud wall.
3/ 2103 fg Roof Below (i.e. selected cladding over omitted for
clarity excluding brick veneer walls).
Climate Code Requirements
Energy efficiency assessor to confirm
adequacy of proposed construction.
PROPOSED FIRST FLOOR PLAN Provide insulation to N.C.C. code requirements
or to BERS certification requirements.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:05 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
1 PCD 2 05/02/2019 BJH
Climate Zone: 2
2 PCD 3 28/02/2019 AOW
Wind Category: To engineers spec.
First Floor
Email: [email protected] 3 Concept Set 1.1 03/03/2019 BJH
Website: www.iconbuildingdesign.com.au 4 Development Application 03/05/2019 BJH Project Issue Date: 03/05/2019 Project Status: Development Application 1.0 Scale: 1 : 100
1.0
Phone: 0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.