Council archive · source document
Attachment 3 Site Plans · OPW19/0177
Attached to the e-mail Operational Works Application OPW19-0177 34-36 Allambi Trc Noosa Heads.msg.
Plans and drawings: the text below has words only, no drawings.
Original PDF page 4, section 5. The text section number identifies this passage in the reader.
7 7
BLK
OW
TO
100mm
W02
+T
35.8 PB
AC AC AC
BOUNDARY
W
1:20 fall
ASTRO
1:20 fa
DP step
1:20 fa
AT DP
50mm step MIN at slab edge to BLK
37
DP structural setdown req'd.
3 055
PB WB 36
1:20 fa
.2 0
BINS TURF DRY COURT
gate dock location
BCA DTS provisions incl. DPC WB
ll
0+
ll
line of roof over line of roof over REN
1,200 MIN. pavers
BOUNDARY
& termite mgmt. stsyem
hc
1:20 AL AFD WB FT2 WB
D07
ll
3 435
fall by 2.0m BACK SETBACK
3 055
l'scaper brick FFL 35.300
fall
DET-18 + Gully RL 35.150 100mm step
DP 1.5m BACK SETBACK FFL 35.300
WD.707 AS brick
SIDE ACCESS DPx2 brick AS
1.2
(post)
BLK REN
sw
0
0
0
0
.6 1
FFL 35.300
gate
.2 1
.6 1
36.2
.2 1
BLK REN
spoon drain to sw
38
mtr box
38
38
38
ramp (1:25)
AS GARDEN 36
hc AS SAC SAC fall fall
OW
OW
OW
OW
step
+T
+T
+T
+T
36.2 finshed path min
BLK REN AS BLK REN
landscaped area, refer 50mm below cladding
Where exhaust fans are either required or Pliable Building Membranes to
TER Noosa Council RAB BCA 2019 part
WIN ATH are provided, to bath, ensuite, WC, BCA 2019 Part 3.8.7.2 and
P 18/0238 3.5.4.7 (pg 216)
m)
SUN laundry or kitchen they are to be ducted to meet AS/NZS4200 Parts 1 &
7a
g(
35.682
in
outside BCA 2019 Part 3.8.7.3. Exhaust 2. Note specific installation
Ris
rates required 40 l/s for laundry & kitchen requirements to openings and
Setting 5 pm
and 25 l/s for bath, ensuite, & WC. penetrations
N Rising (6.30 am
ER H )
UMM PAT 6 125 2 600 1 400 2 390 5 130 6 530 2 650 3 350
S N
m
SU BOUNDARY
0p
5 .3
E B D
A B C D E F G
i ng
tt
Se
WD.603 WD.601 WD.602
EXT. FINISHES LEGEND DP down pipe. MR1 metal roof - (no refers to type). WALL LEGEND GENERAL LEGEND FLOOR FINISH LEGEND BA3
issue
For Building Approval 3
issue / amendment
AC air conditioning EP epoxy flooring. NGL natural ground line. RC masonry blockwork
D04 denotes door number
FT1 FT2 31.07.19 ADG
Indicates extent of TILE
issue date drawn by
AS aluminium screen. FC fibre cement external cladding. PA pavers. W04 denotes window number
RC pool shell/off form concrete client
ASD aluminium sliding door FG fascia gutter. PB plasterboard RL 17.200 denotes finished floor level Deborah and Guy Woollard
C Indicates extent of CARPET
90MM ext. timber frame project
AL aluminium louvres, refer sched. FSC feature stone cladding. PEB pebblecrete pool coating + RL 17.700 denotes spot level Woollard Noosa Heads
location
70MM int. timber frame 50 step
ASD aluminium sliding door. FT1 internal floor tile (refer tile extents plan). PV photovoltic (solar) panel denotes change in level TF TD Indicates extent of TIMBER. 34-36 Allambi Tce Noosa Heads
AFW aluminium framed window. FT2 external floor tile (refer tile extents plan). PF compliant pool fencing brick ext. with timber frame denotes floor waste
MAIN LEVEL PLAN
fw
denotes hard wired smoke GS DR Indicates extent CONCRETE
AT astro turf fill compacted fill. ref. engineer SAC side access concrete. Indicates extent of
alarm BCA 3.7.2 min Aboda Lee Foster • director Scott Falconer • director
chs shs structural posts - refer Design p - 0424 620 247 p - 0431 267 157
hwsa 300mm from wall
awn awning to detail. fire fireplace PW parapet wall. engineer.
Group e - [email protected] e - [email protected]
FINISH CODE LEGEND
the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
5° denotes direction of roof fall ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
BAL1 balustrade-(no refers to type). flue flue kit RC reinforced concrete. t/a aboda design group • BSA License -150580097 • www.aboda.com.au
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
MR denotes roof material denotes additional 'extent' information
BLK masonry blockwork. GL gatic lid, ref. schedule REN render finish TD timber decking to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
SF structural footing, (xxxxxxxx)
Copyright for design & drawings remain the property of the authors • Verify all dimensions on
site prior to commencement of any works • These drawings are not to be used for scaling.
brick feature brickwork HWS hot water service. RF rubber flooring. refer engineer. TS timber screening. DP denotes downpine denotes finish, refer 1000
XX
series drawings for schedule scale as shown @ A2 issue
chute laundry chute HR handrail. SAC service area concrete TER tapered exposed rafters. VER vergola. drawing no.
MAIN LEVEL PLAN CUT site cut join joinery item SBJ silicone butt jointed glass. TF timber floor. VIN vinyl flooring. JXX
denotes item and number.
refer to Joiner for details
WD.202 BA3
SCALE 1:100 @ A2 DS driveway slab LPG LPG gas bottle. SP structural post, refer engineer. TIM timber cladding. WB weatherboard.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 3 Site Plans .pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.