Original source · versioned page text
Bushfire Hazard Assessment & Management Plan v2 - 30 Pottery St Pomona 2021
Bushfire Hazard Assessment & Management Plan v2 NCES REF: J000864 Lot 496 on MCH591 – 30 Pottery St, Pomona 3.3 Quantitative Modelling Quantitative modelling of the potential bushfire conditions that may be experienced within the VHC 9.1 Eucalypt forest to be retained within the west of the site, and present to the south- west and north-west of the site has been undertaken to assist in determining the suitability of the development and any asset setback requirements. The models used comprise industry standard bushfire equations which have been built into the FPAA endorsed FLAMESOL computer model. FLAMESOL allows numerous input variables to be adjusted including fuel loads, fire danger index, site slope and distance to vegetation. FLAMESOL uses the following algorithms: • Rate of Spread – McArthur (1973) and Nobel et al. (1980) • Flame Length – NSW Rural Fire Service (2001) and Nobel et al. (1980) • Elevation of Receiver – Douglas and Tan (2005) • Flame Angle – Douglas and Tan (2005) • Radian Heat Flux – Drysdale (1999), Sullivan et al. (2003) and Douglas and Tan (2005) The FLAMESOL Minimum Distance calculator has been used and comprises an AS 3959:2018 Method 2 (Appendix B) based calculator which will determine standard bushfire behaviour variables as well as the minimum distances required to achieve a range of different radiant heat levels (represented by BAL's). Fuel load inputs have been drawn from Planning for Bushfire Resilient Communities (QFES 2019) based on the calculated potential fuel loads for VHC 9.1 (21 t/ha surface and near surface fuels and 24.2 t/ha total fuels). 1º effective slope was adopted for the slope underlying the VHC 9.1 Eucalypt Forest given across slope to upslope conditions to the west. 6.5º effective slope was adopted for the slope underlying the VHC 9.1 Eucalypt Forest to the north- west, and 8.3º effective slope was adopted for the slope underlying the VHC 9.1 Eucalypt Forest to the south-west. A Forest Fire Danger Index (FFDI) of 47 has been adopted for the site consistent with the assignment by QFES (Catalyst 2020) (refer Plate 8). SITE Plate 8 – FFDI (Source: QFES redi Map) The Flamesol output results are shown in Plate 9 - 11. © 2021 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.