18. A minimum of 3 covered residential spaces plus 1 covered and 1 uncovered visitor space shall
be provided on site.
19. The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004
for user class 1A with allowance for vehicles to enter and leave the site in a forward gear and
with a minimum head clearance (headroom) at any point of 2.2m.
20. All carparking shall be kept, maintained and line-marked in a condition fit for use.
Vegetation Protection & Preservation
21. Vehicular pavements within the drip zone of any of the existing trees on site to be retained
shall be designed as a pervious pavement (such as grass paving cells or similar), as this will
allow water that falls on this surface to penetrate to the trees root system. The pavement shall
be constructed so as not to damage the tree or their root system and in this regard temporary
fencing shall be provided around the trees during construction to help protect them.
22. Where retained tress are located in areas proposed to filled on site (or are located on
neighbouring allotments to the actual site to be filled), there will be a need to prevent fill
material from being placed on the trees root system. To this end the design of the filling works
will need to incorporate terracing around the tree or a similar means of ensuring that the
natural ground level around the trees remains generally the same as existing. These
measures shall clearly be shown on the plans submitted for Building Works approval and any
drainage required to drain these areas shall also be shown on the plans.
Roof Water & Stormwater Drainage
23. Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank
(minimum storage 3000 litres per attached dwelling/unit that is installed to ensure water from
the tank is used for external uses (such as watering gardens, irrigation, ornamental ponds,
water features, topping-up swimming pools, outdoor cleaning, etc) and for use in flushing of
toilets internal to the dwelling. All rainwater tanks are to be designed and installed in
accordance with the Queensland Development Code (QDC), and shall be part of the plumbing
application in conjunction with the building approval. The location and capacity of the tanks
shall be clearly shown on the plans submitted for Building Works approval and any overflow
shall be directed to the road frontage located at Solway Drive
24. All stormwater drainage (including roof water overflow from the rainwater storage system)
shall be collected and discharged so there is no net increase in stormwater runoff from the
site. Stormwater drainage permitted to drain from the site shall be discharged to Council’s
kerb & channel street drainage system in Solway Drive. The maximum discharge of
stormwater drainage allowable to Council’s kerb & channel street drainage system at any one
location is 25 litres/second.
25. All site stormwater drainage shall be by means of a gravity system.
Sewer Mains
26. The site shall be connected to Council’s existing sewerage reticulation systems and be
constructed in accordance with Council’s standards and requirements at no cost to Council.
27. To ensure Council’s sewer main is accessible for maintenance purposes and is protected from
risk of damage no structures requiring a building permit (eg. buildings, swimming pools,
retaining walls exceeding 1m in height, raised terraces, etc) shall be constructed within this
‘zone of influence’ (taken as the area within a 45-degree angle measured from the invert of the
sewer main to the finished surface level) or within 1.5m of the centreline of the sewer main,
whichever is the greater. As such the applicant shall amend Building plans to ensure
compliance.
Town Water Supply
28. The site shall be connected to Council’s existing town water supply and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
Page 3 of 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2007.00002482.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 64 KB (small file)
- File type
No other editions are linked here.