Original source · versioned page text
220623 Church Rehab 'B'
Attached to the e-mail EMAIL 3 OF 3 - MCU22/0031 and OPW22/0062 - INFORMATION REQUEST RESPONSE.
3x Tube dia.
TUBESTOCK PLANT, REFER TO PLANT
SCHEDULE FOR SPECIES
FORM SHALLOW SAUCER SHAPED
DEPRESSION AROUND PLANT BASE
PLANT PIT 2X WIDTH OF 2x POT Ø SHRUB / GROUNDCOVER / TUFTY
100mm DEEP ORGANIC MULCH PER AS RESEPCTIVE POT. SCARIFY ALL GRASS PLANT SPECIES PER PLAN
SPECIFIED. KEEP MINIMUM 50mm PIT WALLS & BOTTOM, TYP. POT Ø
CLEAR OF PLANT STEM. DO NOT
MULCH BIO-AREA MEDIA SAND. BACKFILL PLANT PIT WITH 100mm ORGANIC MULCH AS
TOPSOIL AS PER SPECIFICATIONS, NOMINATED, KEEP MINIMUM 50mm
AVOID COMPACTION, TYP. FROM PLANT STEM. FORM SHALLOW
CULTIVATED SUBGRADE TO 150mm DISH DRAIN TO BASE OF PLANT, TYP.
GARDEN BED TOPSOIL
PER SPECIFICATIONS, AVOID 'AGRIFORM' SLOW RELEASE
COMPACTION, TYP. FERTILISER. TYPE, SIZE & FORMULA
TOPSOIL AS SPECIFIED
STREET TREE PLANTING DETAIL PLAN 100mm, TYP.
PER SPECIFICATIONS. USE FOR
PHOSPHORUS FREE TABLETS FOR
BANKSIA, CALLISTEMON OR
NOTES:
5 gram 'AGRIFORM' TABLET - USE GREVILLEA SPECIES, TYP.
EXTENT OF PIT EXCAVATION TO BE 1800mm x 1800mm IN AREA, MINIMUM
PHOSPHORUS FREE TABLETS FOR 2x ROOTBALL
(SUBJECT TO FOOTPATH LOCATION). REMOVE ALL EXCAVATED FILL OFF-SITE.
CALLISTEMONS & GREVILLEAS DEPTH, TYP.
SPADE CUT EDGE
SUBGRADE 150mm, TYP. 150mm DEEP CULTIVATED
HARDWOOD
SUBGRADE AS PER
STAKES (2), EXISTING SUBGRADE, TYP. SPECIFICATIONS, TYP.
SEE SECTION
STREET TREE,
REFER DETAIL
BELOW. 4 POTTED SHRUB, GROUNDCOVER OR TUFTY GRASS PLANTING
3 TUBESTOCK PLANTING
ROOTBALL LD4 Typical Section Detail N.T.S.
LP4 Typical Section N.T.S.
KERB INVERT
1800mm
ROAD
TOPSOIL WITH
MULCH ABOVE
EDGE, REFER TO DETAIL WASHED GRAVEL
AS SPECIFIED
TURF AS SPECIFIED
150
TOPSOIL AS
'FIGURE 8' HESSIAN TREE TIE, TYPICAL. SPECIFIED, FINISH 25mm
1000mm 1000mm BELOW TOP OF EDGE TO
ALLOW FOR TURF
CENTRE TREE, 900mm FROM BACK OF KERB, OR
SUBGRADE
BETWEEN KERB & FOOTPATH AS APPLICABLE
7 GRAVEL PLACEMENT N.T.S.
LD4 Typical Section
TIMBER SPECIFICATION:
UNSEASONED HARDWOOD, CLASS 1 SELECT GRADE F17, ACQ OR TANALITH E MIN. H4
NOTES: TREATMENT, WITH ONE COAT OF TIMBER COATING.
ENSURE CROWN OF ROOTBALL LEVEL IS
SET HIGHER THAN ADJACENT FINISHED GALVANISED TIMBER
GROUND LEVELS TO PREVENT EXCESSIVE FIXING SCREWS, TYP.
PONDING AROUND ROOTBALL.
FULL & EVEN CROWN, TYP.
FULL & EVEN CROWN, TYP.
50mm WIDE HESSIAN TREE TIES WRAPPED
LOOSELY AROUND TRUNK, THEN A FIGURE 8 &
SECURED TO STAKE. 50mm WIDE HESSIAN TREE TIES WRAPPED ELEVATION
LOOSELY AROUND TRUNK, THEN A FIGURE 8 &
SECURED TO STAKE WITH GALVANISED NAILS
OR STAPLES. POSITION TREE TIE BETWEEN
2 - 50mm x 50mm x 2400mm F14 HARDWOOD 1/3 TO 1/2 OVERALL HEIGHT OF TREE. 1200mm, MAXIMUM
CENTRALLY POINTED NON-TREATED STAKES
(SHOWN PERPENDICULAR TO KERB FOR 2 - 50 x 50 x 2400mm F14 HARDWOOD PLAN
GRAPHIC CLARITY ONLY). STAKES TO BE CENTRALLY POINTED NON-TREATED STAKES.
DRIVEN VERTICALLY INTO GROUND OUTSIDE STAKES TO BE DRIVEN VERTICALLY INTO
OF THE ROOTBALL. GROUND OUTSIDE OF THE ROOTBALL & 100 x 50 mm TIMBER EDGING 50 x 25 x 450mm HARDWOOD PEG
SHALL HAVE A FINISHED HEIGHT LOWER @1200mm CENTRES
THAN THE TREES LOWER LATERAL LIMBS. 20mm
TURF AS SPECIFIED
FORM SHALLOW SAUCER SHAPED FORM SHALLOW SAUCER SHAPED MULCH AS SPECIFIED
1000mm
DEPRESSION AROUND BASE OF PLANT. KEEP DEPRESSION AROUND BASE OF PLANT. 2x HOT DIPPED
min. 1000mm MULCH NOM. 50mm FROM TRUNK BASE. KEEP MULCH NOM. 50mm FROM TRUNK GALVANISED TRIPLE GRIP
CROWN OF TREE 50mm ABOVE KERB HEIGHT 900mm 900mm BASE. SCREW TO FIX MITRED
TIMBER EDGING
100mm DEEP ORGANIC MULCH AS
100mm DEEP ORGANIC MULCH AS TOGETHER, TYPICAL. SECTION
NOMINATED.
NOMINATED. MOUND MULCH AT EDGE OF
2 x POT Ø PLANT PIT TO COLLECT WATER TO FALL
TURF AS SPECIFIED.
DOWN EDGES OF PLANT PIT. DO NOT MULCH
POT Ø WITHIN 50mm OF PLANT STEM.
8 HARDWOOD TREATED GARDEN EDGE N.T.S.
LD4 Typical Detail
TURF OR GARDEN, REFER TO PLAN.
SPADE EDGE
COMPACTED SOIL UNDER TREE
SPADE EDGE, REFER TO DETAIL.
600mm
TOPSOIL PROFILE AS PER GENERAL NOTES
TREE PIT TO BE EXCAVATED TO NOMINAL PROJECT SPECIFICATIONS.
DEPTH VARIES
DEPTH OF 600mm. BACKFILL HOLE WITH
TOPSOIL PER SPECIFICATIONS FIRMING TREE PIT TO BE EXCAVATED TO NOMINAL SPADE CUT EDGE TO TURF & GARDEN TOP SOIL PER
200mm 150mm 300mm
PROGRESSIVELY. EXCESS EXCAVATED SOIL DEPTH OF 600mm. BACKFILL HOLE WITH INTERFACES WHERE NO HARD EDGE IS SPECIFICATIONS
TO BE REMOVED OFF SITE. 100% TOPSOIL PER SPECIFICATIONS FIRMING SPECIFIED, 150mm DEEP.
PROGRESSIVELY. EXCESS EXCAVATED SOIL TURF AS SPECIFIED.
TO BE REMOVED OFF SITE. 100mm THICK ORGANIC MULCH
SCARIFY PIT WALLS & CULTIVATE PIT AS SPECIFIED.
BOTTOM 150mm, TYP. 150mm
150mm CULTIVATED SUBGRADE & PIT WALLS. SLOW RELEASE FERTILIZER AS PER SUBGRADE, FORM TO SUIT
SLOW RELEASE FERTILIZER AS PER MANUFACTURER & SPECIFICATIONS. FINISH LEVEL & CONTOURS.
MANUFACTURER & SPECIFICATIONS.
COMPACTED SOIL UNDER TREE
9 SPADE CUT EDGE AT TURF / TREE GARDEN INTERFACES
1 STREET TREE PLANTING - SPADE EDGES N.T.S. 2 TREE PLANTING - in GARDEN or TURF N.T.S.
NTS
LP4 Typical Section
LP4 Typical Section Detail LD4 Typical Section
Client Project NORT TITLE: JOB No.: S22061152a
anembo consultants
FILE: 220623
Alba Projects Pty Ltd 11c Church St, Pomona DWG. No. LD4
Landscape Architects
Environmental
Project Management
This document is the copyright of anembo consultants & shall Rehabilitation Plan B 23.06.22 AMENDMENTS CK TH SHEET 4 OF 7 anembo consultants pty.ltd.
Sunshine Coast: PO Box 24
A.B.N. 75 089 473 156
Moffat Beach QLD 4551
not be copied without written approval, nor shall it be used
A 17.06.22 COUNCIL SUBMISSION CK TH NTS Ph: 07 5437 0000
except for the development and the site specified. Scale
can not be guaranteed when printing from PDF files. email: [email protected] www.anembo.com
ISSUE DATE DESCRIPTION DRWN CKD ISSUE DATE DESCRIPTION DRWN CKD ISSUE DATE DESCRIPTION DRWN CKD APPROVED: T Hindley ALIA 713 TYPICAL DETAILS NTS
See the original