Original source · versioned page text
Reference Documents - MCU24-0115 [As Published]
4 Pines Noosa Reference: #1869d1-A 81 Noosa Drive, Noosa Heads QLD Date: 20 February 2025 Entertainment Noise Assessment 3.7.2 Sound system configuration during testing The sound system scenario used for testing involved all in-house sound G51 Check Item 39 ☐ systems operating cumulatively. The purpose of this test scenario was to determine the expected maximum intrusive noise level at each affected premises. A test signal was played through the loudspeaker systems, for the purpose of measuring intrusive noise levels at the locations described in Sections 3.1 to 3.4. The source material was selected to be representative of the type of music proposed to be played at the venue (house / club music). The lowest noise limit calculated at the CEMLs across each of the 3 scenarios (plus patron noise, refer to Section 3.8) is considered the final maximum noise limit at the CEML. This is expected to address cumulative noise generated by the venue. 3.7.3 Meteorological conditions during testing Wind speed was collected immediately prior to and following the set of G51 Check Item 40 ☐ intrusive measurements, recording a wind speed of less than 5 m/s using a Kestrel 2000 anemometer. 3.7.4 Method of conducting intrusive noise measurements Intrusive noise measurements were taken at each of the locations G51 Check Item 41 ☐ described in Section 3.1 to 3.4. The source material was played through the sound systems associated with the scenario concurrently, set at a sufficiently loud volume so that the signal was clearly audible and measurable. Where poor signal-to-noise ratio was experienced or where the signal was not audible at an identified RAP, the measurement was still undertaken, along with RPLs and CEMLs relevant to the RAP. 3.7.5 Exclusion of extraneous noise events Extraneous noise events experienced during intrusive noise G51 Check Item 42 ☐ measurements included: road traffic movements, pedestrian noise and birdsong. These noise events were excluded through the use of post- processing of the data (removal of contaminated data and recalculation of the L10 noise descriptor) or using a back-erase function on the sound level meter during intrusive measurements. The back erase function allows acoustic consultants to erase the last 5-seconds of noise measurements where the consultant identifies extraneous noise. 3.7.6 Mechanical plant noise Mechanical plant associated with the venue was identified to be G51 Check Item 44 ☐ comprised of refrigeration equipment and air conditioning plant located directly above the main dining area on the rooftop. It is unknown whether Live It Acoustics | Controlled Document v1.0 Page 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.