Original source · versioned page text
Reference Documents - MCU24-0115 [As Published]
4 Pines Noosa Reference: #1869d1-A 81 Noosa Drive, Noosa Heads QLD Date: 20 February 2025 Entertainment Noise Assessment 5 Conclusion and Recommendations A noise assessment was conducted at 4 Pines Noosa by Live It Acoustics personnel. The assessment demonstrated that noise emanating from the venue could produce nuisance noise at the representative affected premises if noise levels at the source are not managed. Therefore, to comply with the requirements of the Office of Liquor and Gaming Regulation with regards to amplified entertainment at the venue, the following recommendations should be adhered to: G51 Check Item 52 ☐ 1. With all operable doors, all bi-fold windows and the shop window open, noise emanating from the premises, including amplified and/or non-amplified noise must not exceed the following levels, fast response, when measured at: Close external monitoring location 1 (CEML-1) – 7m perpendicular to the main entry doors, 1.5m ESE from the structural post, at the bottom of stairs, at lat/long: 26°23’46.68”, 153°05’22.24” a) 88 dBA between 10:00AM and 6:00PM. b) 65 dBA between 6:00PM and 10:00PM. c) 65 dBC between 10:00PM and 2:00AM. Close external monitoring location 2 (CEML-2) – 4m perpendicular to the venue entry door (via shopping centre), 1m SE of steel post directly next to the bin a) 68 dBA between 10:00AM and 6:00PM. Specific licensed premises area 1 (SPLA-1) – 3m perpendicular to the centre of the mixing desk and 3m from the post-mounted speaker a) 86 dBA between 10:00AM and 6:00PM. b) 83 dBA between 6:00PM and 10:00PM. c) 85 dBC between 10:00PM and 2:00AM. 2. With all operable doors, all bi-fold windows, the shop window closed and with patrons entering the venue only via the sound lock doors, noise emanating from the premises, including amplified and/or non-amplified noise must not exceed the following levels, fast response, when measured at: Close external monitoring location 1 (CEML-1) – 7m perpendicular to the main entry doors, 1.5m ESE from structural post, at the bottom of stairs, at lat/long: 26°23’46.68”, 153°05’22.24” a) 61 dBA between 6:00PM and 10:00PM. b) 71 dBC between 10:00PM and 2:00AM. Specific licensed premises area 1 (SPLA-1) – 3m perpendicular to the centre of the mixing desk and 3m from the post-mounted speaker a) 100 dBA between 6:00PM and 10:00PM. Live It Acoustics | Controlled Document v1.0 Page 24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.