4 Pines Noosa                                                                                                              Reference: #1869d1-A
81 Noosa Drive, Noosa Heads QLD                                                                                           Date: 20 February 2025
Entertainment Noise Assessment

            Table 4: Background LA90 noise level record and calculation sheet for amplified music and patron noise assessment - post-10pm
 POST       RAP.2 - Bottlebrush Avenue Residential Dwellings
                      Measurement Details                     Wind         Noise                   Octave band centre frequencies
 10PM                               Start                                 Descr-                                                                  Overall
           Location Number                   Duration Speed Direction                  63        125        250       500      1000      2000
                                    Time                                   iptor
Row 4-1       B5           1      12:58AM 10 mins < 3m/s                    L90      44 dBZ    41 dBZ     36 dBZ    33 dBZ    29 dBZ    21 dBZ    46 dBZ
Row 4-2     Minus insects/frogs (if applicable)                                      0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ     0 dBZ
Row 4-3     Plus non-standard windscreen attenuation (if applicable)                 0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ     0 dBZ
Row 4-4     Calculated LZ90                                                 L90      44 dBZ    41 dBZ     36 dBZ    33 dBZ    29 dBZ    21 dBZ    46 dBZ
Row 4-5     Overall intrusive noise limit                                   L10      52 dBZ    49 dBZ     44 dBZ    41 dBZ    37 dBZ    29 dBZ    54 dBZ

            Table 5: Intrusive noise measurement data, normalisation & calculation of maximum noise limits to prevent unreasonable noise - post-10pm
            RAP.2 - Bottlebrush Avenue Residential Dwellings
 POST
                     Measurement Details                         Wind       Noise                Octave band centre frequencies
 10PM                               Start                                   Descr-                                                                Overall
           Location Number                   Duration Speed Direction                   63     125        250        500      1000       2000
                                    Time                                     iptor
Row 5-1       Calculated intrusive noise level from ref location + patrons    L10    35 dBZ  26 dBZ     19 dBZ     16 dBZ    11 dBZ     3 dBZ      36 dBZ
Row 5-2     Minus insects/frogs (if applicable)                                       0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-3     Plus non-standard windscreen attenuation (if applicable)                  0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-4     Calculated Intrusive noise level                                  L10    35 dBZ  26 dBZ     19 dBZ     16 dBZ    11 dBZ     3 dBZ      36 dBZ
Row 5-5      Ref.1        10       9:38AM      3 mins     < 2m/s              L10    89 dBZ  80 dBZ     73 dBZ     70 dBZ    65 dBZ     57 dBZ     90 dBZ
Row 5-6     Minus insects/frogs (if applicable)                                       0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-7     Plus non-standard windscreen attenuation (if applicable)                  0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-8     Calculated Intrusive noise level                                  L10    89 dBZ  80 dBZ     73 dBZ     70 dBZ    65 dBZ     57 dBZ     90 dBZ
Row 5-9    CEML-1          9       9:34AM      3 mins     < 2m/s              L10    76 dBZ  68 dBZ     61 dBZ     57 dBZ    53 dBZ     45 dBZ     77 dBZ
Row 5-10    Minus insects/frogs (if applicable)                                       0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-11    Plus non-standard windscreen attenuation (if applicable)                  0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-12    Calculated Intrusive noise level                                  L10    76 dBZ  68 dBZ     61 dBZ     57 dBZ    53 dBZ     45 dBZ     77 dBZ
Row 5-9        0           0          0        3 mins     < 2m/s              L10     0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ      0 dBZ
Row 5-10    Minus insects/frogs (if applicable)                                       0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-11    Plus non-standard windscreen attenuation (if applicable)                  0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ
Row 5-12    Calculated Intrusive noise level                                  L10     0 dBZ   0 dBZ      0 dBZ      0 dBZ     0 dBZ     0 dBZ      8 dBZ
Row 5-13    Source         8       9:30AM      3 mins     < 2m/s              L10   104 dBZ 100 dBZ 102 dBZ 97 dBZ           93 dBZ     86 dBZ 108 dBZ
Row 5-14    Normalisation Moderator                                                 105 dBZ 109 dBZ 100 dBZ 99 dBZ           96 dBZ     95 dBZ 111 dBZ
Row 5-15    Normalised Adj. (reference - measured levels)                             1 dBZ   9 dBZ     -2 dBZ      2 dBZ     3 dBZ     9 dBZ
Row 5-16    Normalised intrusive noise levels, L10,                           L10    36 dBZ  35 dBZ     17 dBZ     18 dBZ    14 dBZ     13 dBZ
Row 5-17    Noise limit at affected premises (Row 1-7)                               52 dBZ  49 dBZ     44 dBZ     41 dBZ    37 dBZ     29 dBZ
Row 5-18    Difference between intrusive & noise limit at affected premises         -16 dBZ -14 dBZ -27 dBZ -22 dBZ -23 dBZ -17 dBZ
Row 5-19    Maximum noise level at Specific Licensed Premesis Area                                                                                125 dBC
Row 5-20    Maximum noise level at Close External Monitoring Location (CEML-1)                                                                    94 dBC
Row 5-20    Maximum noise level at Close External Monitoring Location (CEML-2)
Row 5-21    Maximum noise level at source (3m from speaker)                                                                                       125 dBC




Live It Acoustics | Controlled Document v1.0                                                                                                     Page 49
Log in to download the original file

Reference Documents - MCU24-0115 [As Published].pdf · 4.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.