| @D     Douglas Partners
          Geotechnics | Environment | Groundwater                                            Page 3 of 3

  If future building development on the site is to be fully suspended founding beneath the ‘uncontrolled’
  filling and into natural soils using a deep foundation system and suspended slab, the existing
  uncontrolled filling could be left in place not requiring any further works to reduce potential surface
  movement. The deep foundation system should be design in accordance with AS 2159-2009 “Piling —
  Design and Installation’,

  However, if slab on-ground or pavement construction is required, remove all ‘uncontrolled’ filling and
  sort to remove unsuitable materials and reinstate the excavation with the ‘clean’ sorted filling
  compacted in layers under ‘Level 1’ inspection and testing. This approach would allow for building
  loads to supported on high level footings founded in the new ‘controlled’ engineered filling.

  All earthworks should be carried out in accordance with AS 3798-2007 “Guidelines on Earthworks for
  Commercial and Residential Developments”. The above procedures will require geotechnical
  inspection and testing services to be employed during construction. DP is suitably qualified to conduct
  earthworks inspection and testing services that will be required during any earthworks construction.

  Provided future development on the site is undertaken using the above recommendations along with
  good engineering practice, the site would be considered stable for the intended purpose.

  It is recommended that prior to the finalisation of the specifics of any future development on the site,
  the proposed details of that development should be checked by DP to check against the
  recommendations made in this report and to confirm that the proposed development conforms with
  these recommendations.

  We trust that the above is satisfactory for your current needs. Should you have any questions or
  require any further clarification on this matter, please contact the undersigned at our Sunshine Coast
  office.

  Yours faithfully
  Douglas Partners Pty Ltd
Rosen
  Brett Egen
  Associate

  178 Eumundi-Noosa Road, Noosaville                                                     September 2015

                                                                                             Page 23 of 79
Log in to download the original file

2016-03-01 Planning & Organisation Committee Agenda(PDF, 8MB).pdf · 8.1 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.