Council archive · source document
26281_OW1 to SW1_Issue 9 · OPW19/0278.01
Attached to the e-mail Operational Works Minor Change Application OPW19/0278.01.
BM: NAIL IN KERB
RL: 1.600
43
1. 47
57
1. .40
1. .35
57
5
58 4
61
1.
51 .5
1. 1.4
48
54
1.
1.
1.
1
1
1. 1
PP PP
59
1.
55
54
56
50
54
1.
1.
1.
1.
1.
40
55
WM
1.
1.
WM
66
54
1.
03
1.
58
20.92 20.92
58
2.
1.
59
64
1.
1.
1.
COMMON PROPERTY
94
1.
66
1.
RP78252
17.10
2
2 STOREY
74
1. BRICK UNITS
35.46
2 GTP395
59
67
630m²
1.
1.
6.09
2
3 7
66
1.
77
1.
1.
742m²
SHED
35.46
GTP156216
68
1.
18.36
DECK
IO
MH
LL: 1.53
CP
49
IL: 0.52
1.
50
47
65
1.
1.
1.
14.83 20.92
60
1.
2 STOREY 6 GTP671
SINGLE STOREY
4 RP72986 BLOCK & H'PLANK
BLOCK UNITS
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — Al
LEGEND CONSTRUCTION NOTES
INDICATES EXISTING SURFACE 1. DO NOT SCALE FROM THIS DRAWING.
43.0
2. ALL DIMENSIONS IN MILLIMETRES
CONTOUR AND LEVEL TO AHD. 3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
a ARCHITECTURAL DRAWINGS.
vO 4, ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
» EXISTING SURFACE SPOT LEVELS. ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE ENGINEER
IMMEDIATELY.
5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
FALL, INDICATES DIRECTION OF FALL SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL ENSURE
: THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED
TO FINISHED SPOON DRAINS. CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
LOTS 2 & 3 ON RP 78252 x [29.740 INDICATES PROPOSED FINISHED 1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
i Level Datum AHD SURFACE LEVELS 2. CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES
‘ai 3. CONCRETE DRIVEWAY 10 BE 125mm THK. EXCLUDING ANY
N Level Origin PM 96277, RL 1.635m FINISHED TREATMENTS, EG. STAMENG
GD-150 150(W) GRATED DRAIN WITH 4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5, CONCRETE N25 IN ACCORDANCE WITH AS 1379 AND AS 3600
MOTT)
| | HEAVY DUTY GRATE. 6. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL SLAB
DEPTH.
GP3 450Sq PIPE JUNCTION BOX WITH rn EXPANSION JONTS 1 Be {9m WIDE WET TOOLED WITH EVERY
x BOLTED LID, PRE-CAST 8 ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
2/125x75x4.0 RHS (GALV.) CONCRETE. 8. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE
LAID AT 1 in 100 MIN. 10. ALL SERVICES TO BE LOCATED AND PROTECTED AS REQUIRED
INSTALL TO NEW KERB GP2 — 450Sq FIELD INLET, PRE-CAST PRIOR TO WORK COMWENCING
ADAPTORS AND MAKE CONCRETE WITH RAISED GRATE FOR HYDRAULICS
FOOTPATH COOD LANDSCAPED AREA DRAINAGE. 1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY. REFER TO
: ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION WITHIN. THE
GPS 300Sq FIELD INLET, PRE-CAST ALLOTMENT BOUNDARY TO BE IN ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF AUTHORITIES
CONCRETE WITH RAISED GRATE FOR HAVING JURISDICTION, AFTER OBTAINING ALL NECESSARY PERMITS AND
LANDSCAPED AREA DRAINAGE. APPROVALS.
4, THE CONTRACTOR IS 70 CONFIRM THE POSITION OF ALL EXISTING
r—— RUNOFF TO GRATED DRAINS AND 2/125x75x4.0 RHS (GALV.) STORMWATER VERT. INLETS TO SERVICES AS INDICATED ON THESE AND ASSOCIATED PLANS PRIOR TO
COLLECT PONDING FROM eM ee
SW PITS. 1 in 100 MIN FALL. LAID AT 1 in 100 MIN. 5, STORMWATER DRAINAGE PIPES SHALL BE CLASS SH UPVC OR CLASS
TYPICAL. INSTALL TO NEW KERB NEIGHBORING PROPERTY. 2 R.C.P RUBBER RING JOINTED PIPE AS NOTED LAID AT A MINIMUM
ADAPTORS AND MAKE REFER DETAIL. GRADE OF 1 IN 100 U.N.O. JOINS ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.
FOOTPATH GOOD.
[FI GRATE CONNECT TO 1506 UPVC
4 X X rs e FOOTPATH GOOD. A INDICATES PROPOSED STORMWATER 6. SEWERS 100MM DIAM. UPVC U.N.O. AND LAID AT A MINIMUM GRADE
= x OF 1 IN 60.
&
NO ¢ s .
ML RT “| pe Tl = oN xX 1.40 If a APO 2 tt " SW DRAIN EXISTING MIN 1 in 100 7. WATER SUPPLY PIPEWORK BELOW GROUND IS 10 BE ;
1506 PIPE WITH E Eh pe we E Tr om GRADE U.N.O. 63MM DIAM. OR LESS — HIGH DENSITY TYPE 50
Ww Ng
BOUNDARY
BLOCK BOUNDARY
WALL AS SPECIFIED.
ELIZABETH STREET
FALL LANDSCAPED AREAS TO
FORMED FLOW PATHS 10 DIVERT
FILLED ALLOTMENT 2/125x75x4.0 RHS (GALV.)
TIKES | BLOCK RETAINING LAID AT 1 in 100 MIN.
= WALL.
FILLED ALLOTMENT INSTALL TO NEW KER
7A | 1500 ADJOINING DRAIN FROM ADAPTORS AND MAKE
Ey O
RECTANGULAR GRATE OVER, CLASS 12 POLYETHYLENE
LZ PLACE AT LOW POINTS a
EXIST Ww 8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY PIPEWORK TO BE
3 éL ALONG NEIGHBOURING BLOCK DP DENOTES APPROXIMATE DOWNPIPE TYPE B COPPER.
Oo) LOCATIONS TO BE CONFIRMED BY 9, WATER SERVICES ARE NOT PERMITTED IN GROUND SLABS AND ALL
ts 5 ARCHITECT AND HYDRAULIC JOINS AND CONNECTIONS SHALL BE MADE ABOVE THE SLAB.
EXISTING GROUND LEVEL IN
NEIGHBOURING PROPERTY.
VIA WY)
NEIGHBOURING ALLOTMENT AUSDRAIN ENVIROMODULE 2
SWP1 ~ TYPICAL DETAIL BOTTOM LAYER TO HAVE INFILTRATION CELLS. REFER
A 1509 uPVC PIPE WITH
TRENCH GRATE INSTALLED DETAIL ON THIS SHEET.
~~ IN RETAINING WALL.
ENSURE INLET IS 20mm
1509 uPVC 1 in 100 GRADE TO STORM WATER eae ADYACENT GROUND
PIT ON STREET. IL TO MATCH EXISTING GLIN Ls==—=s .
NEIGHBOURING PROPERTY. 8252
(CP BE XD — a 1 a CPI
! SL 1.65
POOL \ 48]
H jj i
159 uPVC @ 1:100 =
Sw
18 10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE INSTALLED IN
+ DESIGNER. ACCORDANCE WITH AS2419.1. HOSE REELS ARE TO BE INSTALLED IN
AUSDRAIN ENVIROMODULE 2 ACCORDANCE WITH AS2441,
INFILTRATION GELLS. REFER 11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING CAPS SITUATED IN
DETAIL ON THIS SHEET VEHICULAR OR PEDESTRIAN PAVEMENTS ARE TO BE FITTED WITH EITHER
: BRASS OR CAST-IRON COVERS.
ot fl 12, ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE IN APPROVED
1000 uP\G, @ 1:100 | , CONCRETE PATH BOXES.
|
76 || sw y HATCHING INDICATES PROPOSED 13, a WASTE PFES AND WATER SERWCES PENETRATING SLABS TO BE
1.0m WIDE EASEMENT FOR WRAPPED IN AN APPROVED FLEXIBLE JOINT JOINT WRAPPING.
S DP P S 14, THE TERM 'SERVICE” REFERS TO THE MINIMUM INTERNAL PIPE
= / “ AF I e INTER-ALOTMENT DRAINAGE. DIAMETER UNLESS NOTED OTHERMSE,
©
\ -
CT WS 7F
D has)
ne _ +
UNIT 1
FFL 2.70
‘77° RP. BOUNDARY
SECTION X-X
sw
—_—
Sw.
ws
UNIT 2
S
FFL 2.70 S 2ST
sa
5
/ / BRIC
Pe
; _
209 uPyC
Ss SW:
Ww
7 ~
a
715
TN
\
\
IAS
s @
*o
e
rata |
all
os
©
i
ow
oO
a
swt —— sw—>
ON alos 4)" GP3 [2.68430m2 GPa
It \
sw we — Sym 3 4 (aes N
(came = | traé? 742m? LOCATE STORMWATER PITS
C.. “71 #4 AT LOW POINT ON
TT SB NEIGHBOURING PROPERTY
REFER TYPICAL DETAIL.
sw. sw |
THIS SWP PROVIDED AS
DISCHARGE POINT FOR =§$x—————————
NEIGHBOURING ALOTMENT SHED
DRAINAGE,
s
5.40 Swe
Ss
§
— Sw:
.
5
&
‘S
150¢ uPVC @ 1:100
UNIT 4 x
DP
FFL 2.70 y - UTS
D
S Y FFL 2.70
GTP1pt EX. SWPT EXISTING STORMWATER MANHOLE /PIT
EX. SCP EXISTING SEWER CONNECTION POINT
RC. HW. REINFORCED CONCRETE HEADWALL
i EX. SMH EXISTING SEWER MANHOLE
SWP
ay
18.36 —
|W:
oe
MS
EXISTING HCB’s & NEW SW DRAINAGE
LINE TO BE PROTECTED AS PER
SEWER/STORMWATER PROTECTION
DETAILS ON DRG 26281-OW1.
— EX. SMH
Lf RAINFALL '
HATCHING INDICATES PROPOSED
La 1.0m WIDE EASEMENT FOR EX. SOP
a INTER-ALOTMENT DRAINAGE.
ROOF RUNOFF
RP. BOUNDARY
EX. SWMH EXISTING STORMWATER MANHOLE
SWMH NEW 1050 STORMWATER MANHOLE
/ Ys DP]
Y C EX. SCP E.0.B. EXISTING EDGE OF BITUMEN
sw
_ K &C EXISTING KERB é& CHANNEL
L245) | = DF Y a + 328 NS NATURAL SURFACE LEVEL
ft 2a sw——— GP3 = FH. FIRE HYDRANT
| GP3 e——-sw sw POOL CP TP TELSTRA PIT
_ EP. ELECTRICAL POWER POLE
SW SW LE | oo6 ho KERB _EXISTING KERBING
14.83 Swe R.P. | BOUNDARY 20.9
= | 6 GTF
DRIVEWAY SINGLE STOREY RP72986
o
=
DECK
SW
Oo
uU
So
S
—
ty
1
|
|
|
S
1.0m
2 STOREY
LOCK & H'PLANK
Lf FALL LANDSCAPED AREAS TO
L SITE PLAN — STORMWATER MANAGEMENT FORMED FLOW PATHS 10 DIVERT
Scale 1: 200 RUNOFF TO SW PITS. 1 in 100 C___| RETAINING WALLS REVISED 11.02.20
SWP’s ADDED TO SATISFY COUNCIL
INFO REQUEST ITEM 1. (MCU17/0004) | 07/02/17
INFILTRATION PITS INFILTRATION PITS MIN FALL. TYPICAL. ; SW_& DRIVEWAY LEVELS AMENDED. 19/09/17
COMMENCING WORKS ON SITE. ALL SERVICES ARE
REDUCES DEVELOPED SITE RUNOFF TO BE PROTECTED IN ACCORDANCE WITH THE PROVIDE INSPECTION OPENINGS “
ue:
AUTHORITY RESPONSIBLE FOR THE SERVICE (I.0.S) FROM SLOTTED PIPE IN FOR APPROVAL
—TREAT FIRST FLUSH RUNOFF FROM ROOF’S
i @ -STORAGE AND ONGOING INFILTRATION CONTRACTOR TO LOCATE ALL SERVICES PRIOR 10 Revision | Description Date
AUSDRAIN ENVIROMODULE 2 BASE FOR FLUSH OUT or
COUNCIL STORMWATER INFILTRATION CELLS 10 IN LINE, OVERFLOW GRATE WHERE NO DO NOT SCALE FROM THIS DRAWING
SYSTEM THIS DRAWING IS TO BE READ IN CONJUNCTION WRAPPED IN GEOFABRIC STORMWATER OUTLET eaten re copra aad bat tebe used rgradicel mitt
WITH THE STORMWATER MANAGEMENT REPORT BY
the written permission of SCG Consulting Engineers.
WATER CYCLE DIAGRAMATIC SCG CONSULTING ENGINEERS (No. 25231(SWM) stormwater LS 0.5 STORMWATER
email:[email protected]
UNLESS NOTED PROVIDE DROPS AT FACH END remap
web:www.scg-engineers.com
‘ABN 40 098 481 899,
INFLOW OUTFLOW a. Unit 1/11 Project Ave,
Noosa Heads
ALL PIPES TO BE LAID AT 1 IN 100 MIN. t 3 y SCG Ph (07) 5455 5604
DEBUILD T/A
Ke OF THE PIT FROM THE MAIN
THROUGH DRAIN TO THE Title:
— He OLGA OVID Ore ALL PIPE SENTRA tows rove wie crorseet TO OPERATIONAL WORKS:
www.dialbeforeyoudig.com.au Ce OTM OF BE FITTED WTH STAINLESS STEEL PIPE. CLAMPS, STORMWATER MANAGEMENT
y AUSDRAIN INFILTRATION SOAKER PIT DETAIL witrox PROMDED ALONG THS JON LINES Project
SDIAL1100 Lots 2 & 3 RP78252
Oo BEFORE YOU DIG Elizabeth St, NOOSAVILLE
Date: Noy 16 Prawn sk
0 1 2 3 4 5 1100 @ At ; Checked: Drg No. Rev
"15200 @ AS “|S Rcnrdso 26281-SW1 | C.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
26281_OW1 to SW1_Issue 9.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.