08/0066 - Approved Plans [As Published] · 142008.66
Plans and drawings: the text below has words only, no drawings.
NVO04/01/02
LL 1.89
HCB 1.78(10)
OFFSET 1.39
COVER 0.0
TYPE A
sg 5
[G7 i peeeeeay
arrears. 3
TO CLEAR GARAGE DOOR
UNDER
RAISE MANHOLE COVER
TO SUIT NEW SL.
(APPROX 0.52)
WORK TO BE PERFORMED BY
NSC DAY LABOUR
\—oscnaree TO KERB
IL 1.54
5000 L DURAPLAS
LATHCE UNDERGROUND TANK
COMPLETE WITH FIRST FLUSH
DIVERTER & PUMP ALL
SUPPLIED BY MANUFACTURER
5000 L DURAPLAS
LATTICE UNDERGROUND TANK
COMPLETE WITH FIRST FLUSH
OWERTER & PUMP ALL
SUPPLIED BY MANUFACTURER
NL DISCHARGE TO KERB
IL 1.55
N
a
RISE/DROP
FROM
KITCHEN
HWU
RISE. RW FROM
CONTROLLER
~ |
26 L/MIN
GAS HWU
FACTORY SET
TO 50°
HC
PROVIDE
DND SIGN l
:
RISE/DROP
RISE RW FROM
/ CONTROLLER
16 L/MIN
GAS “HWU
FACTORY SET
To 50°
HC
PROVIDE
OND SIGN
26 L/MIN
GAS _HWU
FACTORY SET
Cc
PROVIDE
DND SIGN
CAST SERVICE UNDER
FLOOR SLAB & RISE
IN DUCT
RISE ON WALL
TO RW CONTROLLER.
PROVIOE BACKFLOW
DEVICE AS REQUIRED
BY CONTROLLER
MANUFACTURER
(Dev)
RISE ON WALL
TO RW CONTROLLER.
PROVIDE BACKFLOW
DEVICE AS REQUIRED
BY CONTROLLER
UNIT METER TO BE
CLEARLY &
PERMENANTLY LABELLED
WITH UNIT NUMBER
— fe 8
ar
fo i NEW 259 DOMESTIC SUPPLY
= he REQUIRED
b
\—oscuarce TO KERB
IL 4.56
ROOF
FIRST,
~O
-O
8
—— ee eee
g
°
GROUND
me ee me ee ee ee ee es oe eo
“ SANITARY DIAGRAMMATICS
GENERAL NOTES
+) OBTAIN ALL NECESSARY APPROVALS FROM ALL AUTHORITIES HAVING JURISDICTION
AND PAY ALL FEES DUE.
2)ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY
SANG S SURISOICTION AND WITH THE REQUIREMENTS OF ALL RELEVANT AUSTRALIAN
3) CONFIRM INVERT LEVELS AND LOCATIONS OF ALL EXISTING SERVICES PRIOR 70 THE
INSTALLATION OF ANY ASSOCIATED SERVICES.
4) THESE DRAWINGS ARE A DIAGRAMMATIC REPRESENTATION OF A PROPOSED
PLUMBING AND DRAINAGE INSTALLATION. USE DIMENSIONED ARCHITECTURAL
ORAWINGS FOR SET OUT OF PENETRATIONS RELATING TO PLUMBING FIXTURES.
IT IS THE RESPONSIBILITY OF THE INSTALLER TO CO—ORDINATE THE ON-SITE
INSTALLATION WITH OTHER SERVICES INSTALLATIONS AND STRUCTURE.
DO NOT SCALE THESE DRAWINGS.
5) THE CONTRACTOR IS TO ASCERTAIN THE EXACT LOCATION OF ALL EXISTING
SERVICES PRIOR TO COMMENCEMENT OF CONSTRUCTION AND SHALL BE
RESPONSIBLE FOR THE COST OF RECTIFICATION OF ANY DAMAGE WHICH MAY
OCCUR. THE LOCATION OF EXISTING SERVICES SHOWN ON THIS DRAWING IS
REPRODUCED FROM LOCAL AUTHORITY RECORDS ETC. FOR WHICH NO OPINION
(S EXPRESSED AS TO THE ACCURACY OF SAME.
6) 'AS-CONSTRUCTED' DRAWINGS— WHERE REQUIRED BY THE LOCAL AUTHORITY— ARE THE
RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL RECORD ALL
CHANGES TO ORIGINAL DESIGN AND ALLOW ALL COSTS FOR THE PREPARATION OF
“AS-CONSTRUCTED’ DRAWINGS.
7)AS_A CONDITION OF TENDERING, THE CONTRACTOR SHALL VISIT THE SITE
AND SHALL BE DEEMED TO BE FULLY AWARE OF SITE CONDITIONS.
ANY CLAIM FOR VARIATION ON THE BASIS OF LACK OF KNOWLEDGE OF SITE
CONDITIONS SHALL NOT BE ACCEPTED.
8) WHERE A PARTICULAR MANUFACTURERS PRODUCT IS SPECIFIED OR NOTED,
OTHER MANUFACTURERS PRODUCTS MAY GBE_ SUBSTITUTED.
SUBSTITUTED PRODUCTS MUST HAVE PERFORMANCE AND LONGETIVITY
CRITERIA EQUAL TO OR GREATER THAN THE SPECIFIED PRODUCT.
DOCUMENTED PROOF OF SAID CRITERIA MAY BE REQUIRED.
NOTE: FIRE COLLARS EXCEPTED - REFER NOTE BELOW
9) ARRANGE WITH LOCAL AUTHORITY FOR A 256 WATER CONNECTION
AND PAY ALL FEES DUE.
10) USE EXISTING HOUSE DRAIN CONNECTION, PAY ANY AND ALL FEES OUE.
WATER SUPPLY
1) CW & HW TO INDIVIDUAL POINTS IS 15¢ U.N.O.
2) HW IS 15¢ THROUGHOUT U,N.O.
3) CW TO MORE THAN 1 POINT SHALL BE 206 OR GREATER
4) EXTERNAL HOSE COCKS SHALL BE SUPPLIED WITH 20¢ (MIN)
FEED AND BE FITTED WITH INDIVIDUAL STOP TAPS.
5) SIZING (EG 206) REFERS TO TYPE B COPPER TUBE. REFER
AS 3500,1.2 TABLE 1.1 FOR EQUIVALENT PIPE SIZE IN OTHER
APPROVED MATERIALS.
6) IN NO CASE SHALL A 15@ COLD BRANCH EXCEED 3m IN LENGTH
7) POSITION SERVICES IN CEILING SPACES AND WALL FRAMING U.N.O.
8) JOINTS IN PRESSURED WATER SERVICE PIPES UNDER FLOOR SLABS ARE NOT
PERMITTED,
9) ALL IN~GROUND VALVES SHALL BE ENCLOSED iN APPROVED PATH BOXES.
10) FLOW RESTRICTION DEVICES SHALL BE FITTED WHERE TAP FLOW RATES
ARE NOT SELF—LIMITING. DEVICES SHALL HAVE A MAXIMUM OF 4 LARGE
WATERWAY PORTS TO REDUCE BLOCKAGES. (CONSERV OR SIMILAR)
THEY SHALL BE USED TO RESTRICT FLOWS 70 BASINS, SINKS, SHOWERS
& TUBS TO A MAXIMUM FLOW OF QL/S.
11) HOT WATER PIPE INSULATION SHALL FULLY COMPLY WITH AS3500.4:2003
SECTION 8. MINIMUM R VALUE OF 0,3.
12) TAP OUTLET POINTS SHOWN ON PLAN ARE INDICATIVE ONLY. REFER TO
ARCHITECTURAL AND/OR END CLIENT SPECIFICATIONS FOR PRECISE OUTLET
13) PROVIDE GAS HWU WHERE SHOWN ON FLOOR PLANS
14) INSTALL COLD WATER CONTROLS AND PIPING ON THE INLET SIDE
OF A_HWU TO COMPLY WITH AS 3500.4 AND IN ACCORDANCE
WITH THE REQUIREMENTS OF THE LOCAL AUTHORITY
15) RETICULATE HOT WATER TO ALL FIXTURES EXCEPT HOSE COCKS,
DISHWASHERS AND WATER CLOSETS
16) PROVIDE A S00kPa_ PRESSURE LIMITING VALVE
IMMEDIATELY DOWNSTREAM OF THE DWELLING METER
MATERIALS:
ACRONITRILE BUTADIENE STYRENE, TYPE 8 COPPER, COPPER ALLOY
STAINLESS STEEL, POLYBUTYLENE, POLYETHYLENE, CROSSLINKED
POLYETHYLENE, HIGH DENSITY POLYETHYLENE
WITH LIMITATIONS AS STATED IN AS 3500.
ALL HOT AND COLD WATER SERVICES LOCATED WITHIN A CONCRETE SLAB SHALL BE
ENCASED IN CONDUIT FOR THE FULL DISTANCE INCLUDING ENTRIES & EXITS
FROM THE SLAB Pacey FORMWORK, ACRONITRILE BUTADIENE STYRENE
SHALL NOT BE LOCATED IN CONCRETE SLABS/WALLS.
ABBREVIATIONS
8 BASIN
CWM CLOTHES WASHING MACHINE
oCcv DOUBLE CHECK VALVE
OND DO NOT DRINK
DWM DISH WASHING MACHINE
Eu EXPANSION JOINT
EPD ELEVATED PIPEWORK DROPPER
FPL FINISHED FLOOR LEVEL
FGL FINISHED GRATE LEVEL
FSt FINISHED SURFACE LEVEL
FWG FLOOR WASTE GULLY
HC HOSE COCK
HWU HOT WATER UNIT
lAW IN ACCORDANCE WITH
is INVERT LEVEL
los INSPECTION OPENING TO SURFACE
ORG OVERFLOW RELIEF GULLY
$s SINK
SHR SHOWER
SL SURFACE LEVEL
TS TEST GATE
UNO UNLESS NOTED OTHERWISE
we WATER CLOSET
BACKFLOW PREVENTION
1) PROVIDE BACKFLOW PREVENTION VALVES AS ANO WHERE REQUIRED
BY MANUFACTURER AND/OR LOCAL AUTHORITY TO RAINWATER
CONTROLLER.
SANITARY PLUMBING & DRAINAGE
4) ALL SANITARY DRAINAGE SHALL BE 100 DIA AT 1.65% FALL U.N.
2) MINMUM SIZE OF ACCESS PANELS SHALL BE 600mm X 300mm,
3) ANY FLOOR WASTE GULLY WHICH RECEIVES DISCHARGE FROM A LAUNDRY
TROUGH SHALL BE FITTED WITH AN ANTI-FOAMING GRATE SYSTEM.
MATERIALS:
HOUSE DRAINAGE
SOIL, WASTE AND VENT PIPE
LEGEND
HOUSE DRAINAGE
STORMWATER DRAINAGE,
ROOFWATER DRAINAGE
COLD WATER
HOT WATER
VENT st at ee ee es ee a nt ten ay me ae
NON-POTABLE WATER SUPPLY
EXISTING SEWER
STOP TAP
METER tH?
ELEVATED PIPEWORK DROPPER
PYC CLASS DWV
PVC CLASS DWV
DOWNPIPE a
PROPOSED LEVEL + 318
EXISTING LEVEL x
WALL BASIN
FLOOR WASTE GULLY o
KITCHEN. SINK LOO
TROUGH
WATER CLOSET
O
SHOWER Xx]
U
Gi
WASHING MACHINE
450 x 450. C/PIT WITH A515 x 515 HOG
SUMP GRATE é FRAME EQUAL TO WEBFORGE OQ
MODEL GSC 44H.
STORMWATER & DOWNPIPES
1) ALL STORMWATER ORAINAGE SHALL BE 100 DIA. AT 1% FALL U.NLO.
2) DOWNPIPE SIZES STATED ARE MINIMUM REQUIRED CROSS-SECTIONAL
AREAS. ($008)
MATERIALS:
DOWNPIPES PVC CLASS DW
STORMWATER PVC CLASS SW HEAVY UNO
10
| A 20/12/07 CERTIFICATION Randall Spice | |
REVISION [besignedD TT
{ | SPICE CONSULTING
d CONSTRUCTION HYDRAULICS CONSULTANTS
uot PO BOX 1406 BUDERIM Q 4556 uw
Telephone 07 5445 3888 Netw,
QBSA Facsimile 07 5445 3824 w~. Le
1124616 Email — [email protected] AHSCA
CUENT KJ CONSTRUCTIONS |
ASSOCIATED CONSULTANT JTC CONSULTING
DRAWING : LEVEL: AHD
SITE & FLOOR PLANS SCALE:
ALL SERVICES Al— 1-100 LR
A3- 1:200 <
PROJECT STATUS ISSUE :
PROPOSED DUPLEX APPROVAL L
IOWG. No.
LOT 23 EDWARD ST ne A
NOOSAVILLE 686-01 L
SHEET : 1 OF 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/0066 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.0 MB (small file)
- File type
No other editions are linked here.