Original source · versioned page text
wastewater design
Very large file: it may take a few minutes
The original of this document is very large (13.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
1.00 INTRODUCTION In accordance with the relevant codes, standards and Noosa Councils guidelines, Unearthed Geotechnical P/L was commissioned to undertake a Site and Soil Evaluation at Lot 2 SP241381 Sister Tree Creek Road, Kin Kin. The results form the basis of our recommendations for the on-site treatment and disposal of wastewater from the four proposed one bedroom cabins on this 21.5 hectare rural allotment. A representative of Unearthed Geotechnical P/L was met and shown to the proposed site by the owner, J Williams. Our site investigation fieldwork was performed on 31/01/2022 after some recent seasonal storm/rain activity in the course of the preceding weeks. 1.1 Referenced Standards. Queensland Plumbing and Wastewater Code AS/NZS 1546:2012 On-site Domestic Wastewater Treatment Units AS/NZS 1547:2012 On-site Domestic Wastewater Management AS/NZS 3500 2:1996 Standard Sewerage Law Plumbing and Drainage Code AS 1319:1994 Safety Signs for the Occupational Environment AS 2698 .2:1990 Plastic Pipes Fittings for Irrigation Rural Applications 1.2 Report Limitations. Field Test Limitations The soil profiles detailed in this report should be representative of the soil conditions over this site. In some cases conditions can change dramatically over short distances. If site works reveal soil conditions that are different from those shown in the attached data, the evaluator must be informed immediately as changes may be necessary. Client Supplied Information we have considered the information supplied to us by the client. Should the client have omitted to supply us with relevant information or supplied us with incorrect information our assessment may be irrelevant and/or inappropriate. We do not take responsibility for the consequences in such cases and may incur additional costs if as a result; more testing or re-writing is necessary. 1.3 Copyright. The drawings, specifications and other documents provided by Unearthed Geotechnical P/L remain the property of the Unearthed Geotechnical P/L. Upon receipt of full payment for our service the client is licensed to use the drawings, specifications and other documents for the work/s for which they were commissioned. They shall not be used for any other work except by agreement with Unearthed Geotechnical P/L. Copyright in all the drawings, specifications and other documents remain the property of Unearthed Geotechnical P/L. Unearthed Geotechnical P/L. 1 Design Report 022-003
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.