wastewater design
Very large file: it may take a few minutes
The original of this document is very large (13.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
ADVANCED ENVIRO-SEPTIC’ Advanced Envyiro-septic Design Calculator V8.8 © “Always The First Option” Leader in Passive Solutions _ ‘ieee LOT 2 $P241381 SISTER TREE CREEK ROAD, KIN KIN CABINS 3 & 4 State QLD Post Code 4571 Client N: JODIE WILLIAMS Date of Site Visit 31/02/2022 jame si Designers Ph = DsSiBDES 4S TRELOAR, UNEARTHED GEOTECHNICAL P/L. oe 0417 132 300 Number QBCC740251 Name Number Plumber Ph Plumb / Drainer Plumber Number Lic Number Council Designers AES NOOSA Cert Number Date 2/2/2022 This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer. Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY system Is this a new installation Y or N ¥ >> Minimun single vent size is 80mm or 2 x 50mm house vents Number of person 4 a septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constrants z >>The maximum length of a single AES pipe run is 30 meters Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY § >> Catagory may require design considerations. Ref AS 1547 Design Loading Rate based on site & soil evaluation DLR (mm/day) 8 >> Soil conditioning may be necessary. Ref AS1547 & Comments. Bore log depth below system Basel area 600 |>>Min depth below basel area 600mm check water table/restrictive laye AES FOOTPRINT MUST BE LEVEL WITH TRENCH EXTENSION 7 |>>Consideration reqd for Sloping sites. Ref AS 1547. refer comment. Is this design a gravity system with no outlet filter? Y or N Y >> A House Vent & LOW VENT required on this system PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES COMMENTS : " The outcome must be important to everyone. + Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe. + Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547 ~ All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547. - Plumbers are reminded that good construction techniques as per AS1547 are especilly Important in these soil types. Refer AS 1547 & AES installation Instructions Total System load - litres / day (Q). 480 Vd AES System Extension Area Min Length of AES pipe rows to treat loading 8.0 Im Lith m : (L) Number of FULL AES Pipe lengths per row 3 Iths Width m:(W, ~~ 0.75 0.15 Total Capacity of AES System pipe in Litres 1272 ltr. z . “ Area m2 13.0 47.0 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER yf | >>Slope percentage must be 0% & infiltration footprint must be level | IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER | Y Enter Custom Width in metre 4 AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required . The length & width of excavation required for this design is >> 15.0 x 4 = 60.0 ‘m2 total A trench design has a max of 2 rows of AES pipes located 300mm from up slope side and centered lenght wise in the trench is better. AES-PIPE AES 3 mtr Lths required 6 Iths ee eed sed 4 Digitally signed by ‘ouplings ca ; eninge was Steve Dennis AESO AESO Offset adaptors 4 ca DN: cn=Steve AESODV AES Oxgen demand vent 1 ca Dennis, o=Chankar Enviromental, AES-IPB AES 100mm Inspection point base 2 ea IG BNViNG-SePTIC” ou=Design Review, "Ratu Wastewater Saltions™ AES Equ AES Speed Flow Equaliser ca email=steve@envir o-septic.com.au, AES DESC Double Offset Adaptors ea c=US TOTAL SYSTEM SAND REQUIRED (Guide Only) 20 m3 Date: 2022.02.03 PLE 11:51:51 +10'00' Femail your AES CALC and Drawings (o [email protected] [email protected] > The AES Calculator is a design aid 10 allow checking of the AES components and configuration and is a guide only, Site and soit conditions referencing the AS 1547 standard are calculated und designed by « Quailified Designer > Chankar Environmental has no responsibitity for the soit evaluation, loading calculations or DLR emered by the designer for this cateulaior pipes can be cut to length on site. They are supplied in 3 meter lths only AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty ltd 14/3/2016
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.