EnviroTank Details & Certification
Baseefa Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ United Kingdom BYR =\s¥ i] ANNEX to IECEx BAS 11.0095 Issue No. 0 Date: 2011/08/22 Mains Supply and Relay Contact Terminals TB2 & TB3 Un = 253Vrms Hazardous Area Terminals TB1 Terminal Parameters Uy =12.6V Ip =87mA Py = 273mW C, =0 L, =0 Hazardous Area Terminals TB1 Load Parameters The capacitance and either the inductance or inductance to resistance ratio (L/R) of the load connected to hazardous area terminals TB1 must not exceed the following values: GROUP CAPACITANCE INDUCTANCE OR_|L/R RATIO (uF) (mH) (uH/ohm) IIc as 46 74 IIB 7A 18.7 298 HA 27 876 596 The above load parameters apply where: 1. The external circuit contains no combined lumped inductance L, and capacitance C; greater than 1% of the above values. or 2. or 3. with a cable. The inductance and capacitance are distributed as in a cable. The external circuit contains either only lumped inductance or lumped capacitance in combination In all other situations e.g. the external circuit contains combined lumped inductance and lumped capacitance, up to 50% of each of the L and C values is allowed. The L/R values shown are the worst case values that allow for a single 8 core cable being used. Page 1 of 1