Original source · versioned page text
Bushfire Hazard Management Plan v3 - 27 Wilgee Ct Cooroy
Plans and drawings: the text below has words only, no drawings.
Bushfire Hazard Management Plan v3 NCES REF: J000662
Lot 101 on SP142407, Lot 140 on MCH978, Lot 3 on RP137375,
Lot 2 on RP852009 and Lot 8 on RP160703 - 27 Wilgee Court, Cooroy
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
AO6.4 Safe access and egress will be available to all
building envelopes via the post development
Safe access and egress is available at all times to
conditions (i.e. topography and cleared areas).
all of the development for emergency vehicles
and personnel.
Lot design
PO7 AO7 (a) Building envelopes have been nominated for all
proposed allotments.
Lot design and building siting minimises bushfire Each residential lot:
hazard risk to people and property. (b) The majority of the allotments are of sufficient
a) includes a building envelope, identified on a
size and shape to allow for efficient emergency
plan of subdivision;
access to buildings for fire fighting appliances.
b) is of sufficient size and shape to allow for
Three battle-axe allotments are proposed; Lots 3,
efficient emergency access to buildings for
8 & 9, which are anticipated to still provide efficient
fire fighting appliances (e.g. by avoiding
emergency access to buildings as the access
battle-axe/hatchet lots and long narrow lots
routes are/will be flanked by low threat vegetation
with long access driveways to buildings);
including Lake MacDonald Drive and cleared rural-
c) where more than 2,500m², achieves
residential lots.
setbacks from hazardous vegetation in line
with Bushfire Attack Level 29 requirements (c) All proposed allotments are greater than
as per AS3959; and 2,500m2 and are proposed to be provided with
d) is designed so that buildings and structures setbacks that enable AS3959 Bushfire Attack
are sited in locations of lowest hazard within Level 29 construction requirements or lower.
the lot and elements of the development
(d) All buildings will be surrounded by extensive
least susceptible to fire are closest to the
cleared areas equivalent to low threat vegetation
fire hazard.
conditions.
Firebreaks and fire access tracks
Given the limited scale of hazardous vegetation
PO8 AO8.1
identified adjacent to building envelopes within and
Firebreaks and fire access tracks provide: Where development involves the creation of a adjacent to the site, combined with the irregular
new road and lots, a firebreak is provided by topography including gullies and steep slopes
a) adequate access for fire fighting and other between the building envelopes and retained
providing a cleared road reserve not less than 20
emergency vehicles; and
metres wide and maximum gradient of 12.5% vegetation, the provision of fire breaks between the
hazardous vegetation and the building envelopes