DRAINS Modelling Results - Proposed Site Project number: 20210216 Calculations: B. Parry Street Address: 62 Gateway Drive Locality: Noosaville, NSC Date: 26/09/2022 Site Pre-Post Comparison Current Conditions (10 min Tc) A.E.P Qy Pre (m3/s) Qy Post (m3/s) Qchange (m3/s) Qchange (%) 63.2% AEP 0.042 0.067 0.025 60% 0.5 EY 0.053 0.084 0.031 58% 0.2 EY 0.079 0.106 0.027 34% 10% AEP 0.096 0.123 0.027 28% 5% AEP 0.114 0.140 0.026 23% 2% AEP 0.134 0.160 0.026 19% 1% AEP 0.146 0.175 0.029 20% Site Pre-Post Comparison 2100 Conditions (10 min Tc) A.E.P Qy Pre (m3/s) Qy Post (m3/s) Qchange (m3/s) Qchange (%) 63.2% AEP 0.050 0.080 0.030 60% 0.5 EY 0.069 0.102 0.033 48% 0.2 EY 0.095 0.128 0.033 35% 10% AEP 0.118 0.148 0.030 25% 5% AEP 0.138 0.168 0.030 22% 2% AEP 0.161 0.192 0.031 19% 1% AEP 0.176 0.210 0.034 19%