            Wingara Hills Pty Ltd

                  Topsoil material won from any stripping works associated with construction could be used to
                   supplement the soil within the disposal field.

                  To evenly distribute wastewater throughout the irrigation area, a pressure equalisation system should
                   be installed.

                  Irrigation laterals should be constructed parallel to the natural ground surface contours.

                  A cut off berm or diversion drain must be constructed upslope to divert surface water away from the
                   irrigated area.

                  Signage should be erected at the boundaries of the area in at least two places in accordance with
                   Council requirements to warn people regarding the presence of wastewater pipes (e.g. “Sewage
                   Effluent Pipework Installed Below – DO NOT DIG” or “Recycled Water – Avoid Contact - DO NOT
                   DRINK”).
            Detailed design of the effluent disposal system must be carried out by a Registered Evaluator once the
            facility design is finalised.

            9.0       SUMMARY AND CONCLUSIONS
            From a geotechnical viewpoint, the site is suitable for the proposed development. This recommendation is
            subject to the implementation of the measures specified in this report.
            It is also our opinion that the site is suitable for on-site disposal of effluent. Our assessment indicates that a
            minimum Secondary HSTP with 280 m2 irrigation area is required for the proposed facility.

            10.0 LIMITATIONS
            Your attention is drawn to the document, Limitations which is attached in Appendix F.




            J002915-001-R-Rev0                                  14


Document Set ID: 24031832
Version: 1, Version Date: 14/08/2025
Log in to download the original file

Compiled Reference Documents - MCU25_0091 (As Published).pdf · 15.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.