Original source · versioned page text
Attachment 1E - UNITS 8-9 TYPE 2 DAVID LOW WAY
Attached to the e-mail RESPONSE to Information Request.
PEREGIAN BEACH VILLAS
ELEVATION LEGEND
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
D-0 DOOR NUMBER
WD-0 WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
CN CONCRETE
FL
DP1 90Ø DOWNPIPE
EG1 EAVES GUTTER
FL
FC FIBRE CEMENT WITH 10mm EXPRESSED
Roof sheets @ 120 pitch fixed
0 JOINTS
Roof sheets @ 14 pitch fixed in MRS in accordance with FCC COMPRESSED FIBRE CEMENT
accordance with manufactures manufactures specification FL FLASHING
specification MRS
LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level Ceiling Level
EG1 ZINC ZINC CLADDING WITH STANDING SEAM
FL NGL NATURAL GROUND LINE
Bay window, with specified cladding fixed FL
PLY PLYWOOD WITH 10mm EXPRESSED
in accordance with manufactures JOINTS
specification Aluminium framed windows SPR SPREADER
2,740
2,740
fixed to manufactures SPT SPITTER
specifications
Ballustrade, in accordance with the BCA
Floor Level
and relevant Aus Standards Timber screen Floor Level
Ceiling Level Ceiling Level
Specified cladding fixed in
accordance with manufactures
Steel post in accordance with engineers
specification
specifications
2,740
2,740
Specified cladding fixed in accordance with Open staircase
manufactures specification
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1 Bay window with specified horizontal
cladding fixed in accordance with
Sliding doors on Units 8 & 9 manufactures specification
only, to be double glazed
2,740
2,740
Aluminium framed bifold windows beyond
Ballustrade, in accordance fixed to manufactures specifications
with the BCA and relevant Aus
Standards
Floor Level Floor Level
Fire rated wall in accordance Specified vertical cladding fixed in Ceiling Level
Ceiling Level with manufacturers accordance with manufactures
specifications specification
Aluminium framed doors fixed Steel post in accordance with engineers
2,740
2,740
to manufactures specifications specifications
Sliding doors on Units 8 & 9 only, to be
1800H Timber fence double glazed
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 20.03.14
PEREGIAN BEACH VILLAS
D 16.01.14 Amend GFA CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
E 22.01.14 Client request amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
F 24.01.14 Client request amendments CT Date:
UNITS 8-9 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, G 07.02.14 Amend areas & Kitchen layout CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
H 25.02.14 Amend design CT NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD.
I
J
04.03.14 Amend design & balcony
20.03.14 Amend design & Areas
CT
CT
ECO REMOTE A.01.4 J
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.