   BUSHFIRE MITIGATION REPORT
             FM 5601
               for
        ZACCALE PTY LTD
                at
       11C CHURCH STREET
            POMONA



           PREPARED BY
ELDON BOTTCHER ARCHITECT PTY LTD
       145 VARSITY PARADE
          VARSITY LAKES
          PH 07 55920082
    EMAIL [email protected]
            15/06/2022
Log in to download the original file

FMP 11C CHURCH STREET POMONA -1.pdf · 137 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

Full text of the other 44 pages

Page 2

                                                                             FIRE MANAGEMENT REPORT FM 5601
TABLE OF CONTENTS
DISCLAIMER
1. INTRODUCTION
        1.1.          Address
        1.2.          Local Authority
        1.3.          R.P.D.
        1.4.          Site Area
        1.5.          Responsible Fire Authority
        1.6.          Potential Bushfire Hazard Rating.
        1.7.          Land Tenure
        1.8.          Adjoining Owners
        1.9.          Current Land Use
        1.10.         Fire Danger Index
        1.11.         Topography
        1.12.         Predominant Wind Direction
        1.13.         Slope
        1.14.         Aspect
        1.15.         Fuel Type
        1.16.         Threat Vegetation Location
        1.17.         Fire History
        1.18.         Location of access tracks
        1.19.         Location of fire breaks
        1.20.         Location of existing firefighting infrastructure
        1.21.         Historical and cultural sites

   2.   SITE AND HAZARD ASSESSMENT
        2.1.        Discussion with Responsible Fire Authority
        2.2.        Vegetation Types
        2.3.        Potential Bushfire Hazard Rating.
        2.4.        Building Construction
        2.5.        Ecological Requirements

   3.   RISK MANAGEMENT PLAN
        3.1.        Agencies / Persons Responsible
        3.2.        Bushfire Safety Objectives
        3.3.        Aims
        3.4.        Functional Requirements
        3.5.        Proposed Fire Fighting Infrastructure
        3.6.        Circulation Road Layout
        3.7.        Building Construction
        3.8.       Street Numbering
        3.9.       Less Flammable Landscaping
        3.10.      Insurance
        3.11.      Emergency Response Procedures
        3.12.      Community Awareness Strategies
        3.13.      Administering Staff

   4.   FIRE MANAGEMENT ACTION SUMMARY AND SCHEDULE

   5.   APPENDICES
        5.1.       Form 15
        5.2.       Site Plans
        5.3.       Bushfire Hazard Mapping
        5.4.       Regional Ecosystem Mapping
        5.5.       Aerial Photos
        5.6.       Site Photos
        5.7.       Completed Overlay Code
        5.8.       Supporting Information

   6.   PROFILES




                   ELDON BOTTCHER ARCHITECT PTY LTD                      ©     15/06/22                   2

Page 3

                                                                                         FIRE MANAGEMENT REPORT FM 5601
DISCLAIMER


Experienced fire fighters with extensive knowledge of building have prepared this Report. Their practical knowledge of fire fighting
has been backed up by academic study.

However, fire is an element of nature. Small natural occurrences can disastrously affect the outcome of the best planning. Human
actions similarly can have disastrous results.

Whilst every care has been taken in the formulation of this management report, there can be no guarantee that even the strictest
adherence to its recommendations can guarantee safety of life and property.

The authors of this report accept no responsibility for any damage to life or property caused by fire or any other cause to persons
using land or structures, which could in any way be construed to be the subject of this report.

The report has been commissioned as the land falls within an area deemed a fire risk by the local authority.

As such, it must be recognized that structures upon this land and those using the structures could be deemed at risk.

Logo by LogoInstant


Very Important Note;
This report is valid for the following periods;
     a) A maximum time of 5 years from date of preparation.
     b) The currency of the legislation referred to in Section 1 Report Brief
     c) Changes to any legislation generally that may impact on the report outcomes.
     d) Changes to vegetation, both on and off site, which may impact on the results of this report
     e) Any other changes that may impact on the report in any manner.




                        ELDON BOTTCHER ARCHITECT PTY LTD                       ©             15/06/22                             3

Page 4

                                                  FIRE MANAGEMENT REPORT FM 5601




THE COPYRIGHT ACT AND MORAL RIGHTS ACT PROTECT THIS REPORT.

IRRESPECTIVE OF THIS REPORT APPEARING ON A COUNCIL PD OR OTHER
ONLINE SITE, THERE IS NO PERMISSION IMPLIED OR GIVEN TO ANY PARTY
TO DOWNLOAD OR TO USE THIS REPORT IN WHOLE OR IN PART IN ANY
MANNER OTHER THAN THAT FOR WHICH IT WAS ORIGINALLY PREPARED.
ANY SUCH USE WILL BE PROSECUTED TO THE FULL EXTENT OF THE LAW.

THIS REPORT RELIES ON THE AS 3959 FOR THE CALCULATION OF
CONSTRUCTION LEVELS.
ANY POSSIBLE ERRORS IN THE STANDARD ARE NOT THE RESPONSIBILITY
OF THE AUTHOR.

THIS REPORT IS ONLY TO BE USED AND DISTRIBUTED AS A COMPLETE
REPORT CONTAINING AS A MINIMUM SECTIONS 1,2,3,4 AND 5 (SECTIONS
5.1 & 5.2)

THIS REPORT IS NOT TO BE AMENDED IN ANY WAY BY ANY PERSONS
OTHER THAN THE ORIGINAL AUTHOR.

THIS REPORT IS ONLY TO BE USED FOR PROJECTS IDENTIFIED IN THE
REPORT AND REPRESENTED ON THE SITE PLAN ACCOMPANYING THE
REPORT.




           ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                   4

Page 5

                                                                                  FIRE MANAGEMENT REPORT FM 5601
                                                  INTRODUCTION

This Fire Management Report has been written for the benefit of future occupants of this proposed site and developed in
accordance with the requirements of;
    o The Noosa Shire Council Town Plan,
    o SPP 07/2017.
    o Queensland Planning Act 2016
    o “Bushfire Resilient Communities Technical Reference Guide for the State Planning Policy State Interest” Natural
         Hazards , Risk and Resilience-Bushfire” published by QFES and Queensland Government.
    o Natural hazards, risk and resilience-Bushfire State Planning Policy-state interest guidance material published by
         Queensland Government
    o Bushfire Resilient Building Guidance for Queensland Homes published by CSIRO and Queensland Government
    o The National Construction Code
    o Queensland Bushfire Plan published by Queensland Government prepared by QFES.
    o Australian Standard AS3959,
    o International Fire Safety Engineering Guidelines

The report has been prepared as supporting documentation for a Material Change of Use (Building) /Reconfiguration of Lot
Application.

1.1.        Address:
            11C Church Street
            Pomona

1.2.        Local Authority
            Noosa Shire Council

1.3.        R.P.D.
            Lot 4 on SP301620

1.4.        Site area
                   2
            7509m

1.5.        Responsible Fire Authority
            QFES for all fires.

1.6.        Potential Bushfire Hazard Rating.
            The hazard rating maps prepared for the Council show the ratings on this property ranging from Low to being in
            a bushfire hazard buffer area.

1.7.        Land tenure
            Freehold

1.8.        Adjoining owners are:
            Freehold

1.9.        Current Land Use:
            Vacant

1.10.       Fire danger Index
            FDI 40 (nominated by AS 3959)

1.11.       Topography
            Rolling Hills

1.12.       Predominant Wind Direction
            The predominate wind direction is from the South East. In times of severe fire weather the wind direction will be
            from the North West. The Topography will create microclimates, which will cause swirling, which will modify the
            apparent wind direction according to primary direction and velocity

1.13.       Slope
            upslope

1.14.       Aspect
            Variable




                  ELDON BOTTCHER ARCHITECT PTY LTD                       ©             15/06/22                            5

Page 6

                                                                                 FIRE MANAGEMENT REPORT FM 5601
1.15.   Fuel Type
        Predominate vegetation
          REGIONAL         VHC    VHC DESCRIPTION          SURFACE        TOTAL        COMMENTS
          ECOSYSTEM                                        FUEL LOAD      FUEL LOAD
          12.9-10.17       9.2    Moist to dry eucalypt    11.4           17.2         Mapping identifies two other
                                  woodland on coastal                                  Regional     Ecosystem       areas
                                  lowlands and ranges                                  impacting the site.
                                                                                       Site inspection reveals that these
                                                                                       areas are mowed grassland or
                                                                                       severely modified waterway
                                                                                       areas with no resemblance to the
                                                                                       mapped RE’s

1.16.   Threat Vegetation Location
        Portion of the southern end of Pottery Street. Vegetation west of Pottery Street is more than 100m from the
        subject site and is therefore not considered as threat.
        Western end of Memorial Avenue.
        The above areas comply with the mapped Regional Ecosystem
        Vegetation located on the southern part of adjoining Lot 1 on RP66341 is either managed to a Low threat status
        or is modified riparian vegetation along the creek line that does not constitute a threat for bushfire purposes.

1.17.   Fire History
        There is possible evidence of a recent fire event south of Memorial Lane

1.18.   Location of Access Tracks
        The site is served by a sealed road system

1.19.   Location of Fire Breaks
        There are formal firebreaks consisting of managed and Low threat vegetation and a formed road system more
        than 100m in all directions except to the south where the threat vegetation in Memorial Drive is situated within
        100m of the proposed Unit 13.

1.20.   Location of existing firefighting Infrastructure
        The site is served by reticulated water

1.21.   Historical and Cultural Sites
        There is no evidence of Historical and Cultural sites on the property.




              ELDON BOTTCHER ARCHITECT PTY LTD                       ©             15/06/22                            6

Page 7

                                                                                        FIRE MANAGEMENT REPORT FM 5601
2.   SITE AND HAZARD ASSESSMENT

     2.1.       Discussion with Responsible Fire Authority
                The fire management report has not been discussed with the Fire Brigade.

     2.2.       Vegetation Types
                The vegetation type predominate to this site are as scheduled in section 1.15


     2.3.       Potential Bushfire Hazard Rating.
                Site inspection and visual assessment against the State Planning Policy Mapping Methodology generally
                confirms the intent of both Local Government and State Mapping in that the area is in a Potential Bushfire Hazard
                Area, and the relevant aspects required for Town Planning and Building are to be addressed.

     2.4.       Building Construction
                All buildings situated within the site are in a Designated Risk Area. There is a requirement that certain Buildings
                within this area be constructed in accordance with the Building Code of Australia, which refers to either the
                Australian Standard for Construction in Bushfire Prone Areas or NASH Standard-Steel Framed Construction in
                Bushfire Areas.
                The levels determined effect the types and usage of materials in relation to the type of Bushfire Attack, which
                may occur as assessed under the Standard. The Level of Bushfire Attack is assessed taking the vegetation
                types, slope, and distance from vegetation into account. The most common elements affected are Windows and
                flyscreening, with some restrictions on cladding and timber types. A comprehensive breakdown is available in
                either the National Construction Code or the Australian Standard for Construction in Bushfire Prone Areas.
                Extracts of these documents are not provided due to copyright reasons. Full details can be obtained from your
                building designer or certifier.

                Note that the Building Code of Australia only requires Classes 1,2 and 3 buildings and Class 10a building
                associated with those buildings to comply with the requirements of AS 3959.

                Measurement from aerial photos indicates that Unit 13 only is within 100m of threat vegetation and must
                comply with AS 3959, as assessed as BAL 12.5 below. All other units are BAL Low.


                Building Class requirements AS 3959

       2.4.1.    FDI                                                              40
       2.4.2.    Vegetation Classification                                        A
       2.4.3.    Land slope                                                       Upslope

                    Distance of building from Predominate vegetation              Primary Bushfire Attack Level
                    class
                    (Vegetation Management Zone)
                    28-<100                                                       BAL-12.5
                    100-                                                          BAL-LOW

                Note:
                The levels shown above are based on Method 1 of the AS 3959.

                The Vegetation management zone is described as all areas managed to a Low Threat condition encompassed
                by the distance between the building and threat vegetation from which construction levels are taken.

                The Vegetation management zone is the area between unmanaged vegetation (i.e., the covenant areas)
                and the buildings, existing and proposed.


                The distances shown above are horizontal distances, not measured along the slope.

                Construction Levels are shown as part of a comprehensive Bushfire Management Plan.

                They are provided for the end user of the land and its eventual occupants.

                They are not provided for assessment by Local Authority, in accordance with the Planning Act 2016, and The
                Building Act 1975.

                Compliance with the Performance Requirements of the Building Code of Australia, P2.3.4 Bushfire areas states;



                     ELDON BOTTCHER ARCHITECT PTY LTD                         ©              15/06/22                            7

Page 8

                                                                                      FIRE MANAGEMENT REPORT FM 5601
               A Class 1 building or a Class 10a building or deck associated with a Class 1 building constructed in a designated
               bushfire prone area is to provide resistance to Bushfire in order to reduce the danger to life and reduce the risk
               of the loss of the building.

               Section 3.7.4.0 of A. Acceptable Construction Manual (Queensland Variation) states that

               a) Subject to (b), Performance Requirement P2.3.4 is satisfied for-
               i) a Class 1 building; or
               ii) a Class 10a A building or deck associated with a Class 1 building,
               located in a designated bushfire prone area if it is constructed in accordance with AS 3959.
               b) The requirements of (a) do not apply when the classified vegetation is Group F rainforest (excluding wet
               sclerophyll forest types), mangrove communities and grasslands under 300mm high.”

               Therefore it must be considered that compliance with any Construction Level of AS 3959 satisfies the
               Performance Requirements of Building Code of Australia, and all construction levels therefore are to be
               considered as mitigating risk in an equal manner.

               The Planning Act 2016 Section 8 What are Planning Instruments (5) and (6) state;

               (5) A local planning instrument must not include provisions about building work, to the extent the building work
                   is regulated under the building assessment provisions, unless permitted under the Building Act.
               (6) To the extent a local planning instrument does not comply with subsection (5), the local planning instrument
                   has no effect.

               The Building Act 1975, Section 31 states;

               “(4) A local law, local planning instrument or local government resolution must not include provisions about
               building work, to the extent the building work is regulated under a code under subsection (3).
               (5) To the extent a local law, local planning instrument or local government resolution does not comply with
               subsection (4), the local law; local planning instrument or local government resolution is of no effect.
               (6) Subsections (3) to (5) are subject to sections 32 and 33.”

2.5.           Ecological Requirements
               There are specific ecological requirements in relation to bushfire management. These are addressed in Section
               3.9 of this report.


       Note;
       The Category of Bushfire Attack referred to in the Australian Standard is different to the Hazard/Risk area referred
       to above.

       Extensive modification of the existing vegetation types including that on adjoining sites could result in a change
       of Category of Bushfire Attack and therefore variation in the Level of construction required.

       It is the responsibility of the owner of each individual site to ensure that plantings subsequent to their occupation
       of the site do not reduce the safety of their buildings in a manner, which could require a higher level of
       Construction than that originally utilised




                     ELDON BOTTCHER ARCHITECT PTY LTD                       ©             15/06/22                             8

Page 9

                                                                                             FIRE MANAGEMENT REPORT FM 5601
3.   RISK MANAGEMENT PLAN

     3.1.            Agencies / Persons Responsible
                     The responsible Fire Authority is the Rural Fire Service Queensland through the Rural Fire Brigade being
                     responsible for Bush Fires and the Queensland Fire and Emergency Service being responsible for Structural
                     Fires
                     It is the responsibility of the Developers and Owners of the properties to ensure that the relevant measures
                     required by this Management Report are in place prior to inspection by the Council and the Building Certifier
                     and to ensure that those measures are in place prior to the occupation of any buildings, which are the subject
                     of this report. It is the responsibility of Council and Building Certifiers to ensure that relevant measures within
                     their responsibility are in place prior to the issuance of any certification.

     3.2.            Bushfire Safety Objective
                     The objective of this report is to minimise potential risk to life and property by protecting the buildings from the
                     effects of bushfire.

     3.3.            Aims
                     The aims to achieve this objective are to mitigate the effect of the bushfire attack mechanisms of: -
            3.3.1.   Radiant Heat
            3.3.2.   Direct Flame Contact
            3.3.3.   Wind
            3.3.4.   Ember Attack
            3.3.5.   Smoke

     3.4.            Functional Requirements
                     The functional requirements to achieve this objective are: -
            3.4.1.   The provision of safe conditions for fire fighters
            3.4.2.   The provision of safe conditions for residents
            3.4.3.   Ensure adequate and safe access to and from the property
            3.4.4.   Ensure adequate and safe water supply to the property and the establishment of firefighting water reserves
            3.4.5.   Provide a system of fire breaks and trails to protect the building component
            3.4.6.   Remove vegetation that is considered dangerous and a hazard in Fire Conditions
            3.4.7.   To ascertain the required standard of construction of the buildings in accordance with the requirements of the
                     National Construction Code and the Australian Standard for Construction in Bushfire Prone Areas or the
                     provision of a satisfactory alternative solution
            3.4.8.   Facilitate the return to “normalcy “

     3.5.            Proposed Fire Fighting Infrastructure
            3.5.1.   The proposed buildings are to be served by a reliable reticulated water supply.

     3.6.            Circulation Road Layout
                     The access road is to comply with “Fire Hydrant and Vehicle Access Guidelines for Residential, Commercial
                     and Industrial Lots” published by QFES and Qld Government.

     3.7.             Building Construction
                     All construction is to be in accordance with Australian Standard AS 3959 2018 Construction of Buildings in Bush
                     Fire-Prone Areas and the Level of construction assessed under “Site and Hazard Assessment.”

     3.8.            Street Numbering
                     Numbering is to be installed in accordance with the current Street Numbering System at time of completion of
                     building.

     3.9.            Less Flammable Landscaping
                     Any new landscaping within the site, including rehabilitation of the waterway area. is to be Less Flammable, in
                     accordance with the list enclosed as an Appendix at the rear of this Report, rainforest species, or cultivated
                     gardens, and comply with the requirements of “ Bushfire Resilient Communities Technical Reference Guide for
                     the State Planning Policy State Interest” Natural Hazards , Risk and Resilience-Bushfire” published by QFES
                     and Queensland Government, and “Natural hazards, risk and resilience-Bushfire-Assessment Benchmark 5”
                     which cite a maximum Fuel Load of 8t/ha for revegetation or rehabilitation within bushfire prone areas.
                     “Bushfire Resilient Building Guidance for Queensland Homes” published by Qld State Government provides a
                     schedule of species in Appendix E.
                     https://www.qra.qld.gov.au/bushfireguideline

     3.10.           Insurance
                     Failure to comply with this management report may have a detrimental effect upon the Insurance of the subject
                     Buildings.



                           ELDON BOTTCHER ARCHITECT PTY LTD                        ©             15/06/22                              9

Page 10

                                                                                  FIRE MANAGEMENT REPORT FM 5601




3.11.       Emergency Response Procedures
            In the event of Fire Emergency, assistance is to be obtained by dialling 000

    3.11.1. The owner should read thoroughly the brochures contained and those recommended at the rear of this report.
            They contain valuable information that could assist in the saving of lives and property in a fire event!

3.12.       Community Awareness Strategies
    3.12.1. Each subsequent owner is to be provided with a copy of this Fire Management report with an alert placed on
            either Title or Council Rate searches that the Report is in existence and is to be made available to ensuing
            owners.

3.13.       Administering Staff
            It is the responsibility of the developers and owners to ensure compliance with this Report and the Town Plan,
            and to ensure that each of the new owners is provided with a copy of this report.

            It is the responsibility of the Council and the Building Certifier to ensure that the relevant measures
            required by this management report are in place prior to the final completion stage inspection of any
            buildings on any sites which are the subject of this report as noted in Clause 3.1 of this report.


            It is the responsibility of the ensuing owners of the properties to maintain the properties in the conditions
            outlined in this report.




                 ELDON BOTTCHER ARCHITECT PTY LTD                      ©             15/06/22                          10

Page 11

                                                                         FIRE MANAGEMENT REPORT FM 5601
4.   FIRE MANAGEMENT ACTION SUMMARY AND SCHEDULE


 DEVELOPMENT REQUIREMENTS     BUILDING                                  MAINTENANCE
                              REQUIREMENTS
                              Buildings to comply with the Australian   Regular mowing and maintenance of the
                              Standard for Construction within Bush     vegetation areas as set out in this report.
                              Fire Prone Areas.
                                                                        Drive to be kept clear and accessible to
                              No occupation until compliance with       satisfaction of the Fire Brigade.
                              Standard and Management Report
                                                                        Building materials are to be maintained in “as
                                                                        new “condition to preserve the integrity of the
                                                                        relevant materials.




                 ELDON BOTTCHER ARCHITECT PTY LTD              ©            15/06/22                              11

Page 12

                                                                                                  FIRE MANAGEMENT REPORT FM 5601
5.   APPENDICES
     5.1. Form 15
     5.2. Site Plans
     5.3. Bushfire Hazard Mapping
     5.4. Regional Ecosystem Mapping
     5.5. Aerial Photos
     5.6. Site Photos
     5.7. Completed Overlay Code
     5.8. Supporting Information

     Note. These items below are referenced for information purposes only and are not to be construed as
     being part of the management report
     This information is generic and not provided for approval purposes.
     It is only provided for end user knowledge
                 5.8.1. Planning Regulation Fact Sheet December 2019
                 5.8.2. Prepare. Act. Survive
                 5.8.3. Rural property Fire Management Guide 2010
                 5.8.4. Notes for Landholders
                 5.8.5. Bushfire Action Guide
                 5.8.6. Bushfire Safety in Urban Fringe Areas
                 5.8.7. Water + Power -Vital for Fire fighting
                 5.8.8. Less Flammable Vegetation
                 5.8.9. Fire Retardant Native Plants
                 5.8.10. Tree selection for Fire-Prone Areas
                 5.8.11. Bushfire Resilient Building Guidance for Queensland Homes Appendix E
                 5.8.12. First Draft (specifying timber in bush fire zones)
                 5.8.13. External water spray system
                 5.8.14. Fire Retardant Coating Solutions
                 5.8.15. Archicentre Bushfire Design Guide
                 5.8.16. Section 3.8 Sign Types - Fire Trail Signage of the GCCC Natural Areas Management Unit    Signage   Guidelines
                         (Page 16)
                 5.8.17. Trail Number and Key Point signage
                 5.8.18. Bushfire Hydrant detail
                 5.8.19. Tank detail
                 5.8.20. Recycled Water for Firefighting
                 5.8.21. Sample Easement Document
                 5.8.22. Bushfire Windows and Shutters
                 5.8.23. A guide to retrofit your home for better protection from a bushfire.
                 5.8.24. FireFly BAL-FZ System
                 5.8.25. Bushfire Planning and Design Certification Scheme Update
                 5.8.26. Eaves Water System
                 5.8.27. Aussi Ember Guard
                 5.8.28. The Australian “False Alarm: the great rainforest fire that wasn’t”
                 5.8.29. Hijacking Australian 2019 Bushfire Tragedies to Fearmonger Climate Change
                 5.8.30. Bushfires have been in Australia for over 60 million years

     We also recommend that the landholder obtains and reads the following;

                 5.8.31. Bushfire Hazard Planning in Queensland
                 5.8.32. Protecting your home against Bushfire
                 Both available from the Dept. of Local Government and Planning, and

                 5.8.33. Fire in Bushland Conservation
                 Available from Queensland Heritage Trust.

                 5.8.34. Bushfire Resilient Building Guidance for Queensland Homes
                 https://www.qra.qld.gov.au/bushfireguideline

          Signed


         E J Bottcher
          Eldon Bottcher
          Grad. Dip. DBPA (UWS) Dip. Arch. (QIT), Cert. R.F.M. (USQ), F.R.A.I.A., M.A.I.E.S. AIFireE
          Architect
          BPAD-L3 Practitioner




                         ELDON BOTTCHER ARCHITECT PTY LTD                             ©                15/06/22                    12

Page 13

                                       FIRE MANAGEMENT REPORT FM 5601




                                                    APPENDIX 5.1
                                                        FORM 15
ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  13

Page 14

                                                                                             FIRE MANAGEMENT REPORT FM 5601




Form 15—Compliance certificate for building design or specification
This form is to be used by an appointed competent person for the purposes of section 10 of the Building Act 1975 and sections 73 and
77 of the Building Regulation 2012(Design-specification certificate) stating that an aspect of building work or specification will, if
installed or carried out a stated in this form, comply with the building assessment provisions.

Additional explanatory information is included in the Appendix at the end of this form.


1. Property description                   Street address (include no., street, suburb/locality and postcode)
This section need only be                  11C Church Street Pomona
completed if details of street
address and property description                                                                          Postcode
are applicable.
E.g. in the case of                       Lot and plan details (attach list if necessary)
(standard/generic) pool design/shell       Lot 4 on SP301620
manufacture and/or patio and
carport systems this section may          In which local government area is the land situated?
not be applicable.                         Noosa Shire Council
The description must identify all
land the subject of the application.
The lot and plan details (e.g.
SP/RP) are shown on title
documents or a rates notice.
If the plan is not registered by title,
provide previous lot and plan
details.
2. Description of                          Work as required for bushfire mitigation purposes as set out in the Bushfire
   component/s certified                   Management Report prepared by Eldon Bottcher Architect Pty Ltd including
Clearly describe the extent of work
covered by this certificate, e.g. all
                                           assessment of Construction Levels assessed under AS 3959.
structural aspects of the steel roof
beams.




3. Basis of certification
                                           Compliance with the Bushfire Management Report prepared by Eldon Bottcher
Detail the basis for giving the
certificate and the extent to which        Architect Pty Ltd
tests, specifications, rules,              No certification of components covered by The Building Act 1975, The
standards, codes of practice and other     building Code of Australia or AS 3959.
publications, were relied upon.
                                           Noosa Shire Council Town Plan Bushfire Management Constraint code.


4. Reference documentation                 Bushfire Management Report FM 5601
Clearly identify any relevant
documentation, e.g. numbered
structural engineering plans.




                               ELDON BOTTCHER ARCHITECT PTY LTD                   ©            15/06/22                          14

Page 15

                                                                                    FIRE MANAGEMENT REPORT FM 5601



5. Building certifier reference                Building certifier reference number
   number and building
   development application
   number                                      Building development application number (if available)
                                               Not Available

6. Appointed Competent                         Name (in full)
 person details                                 Eldon John Bottcher
Under Part 6 of the Building Regulation a
person must be assessed as competent           Company name (if applicable)                   Contact person
for the type of work (design -specification)
by the relevant building certifier.             Eldon Bottcher Architect Pty Ltd               Eldon Bottcher
                                               Phone no. (business hours) Mobile no.                   Fax no.
                                                07 55920082               0412434134
                                               Email address
                                                [email protected]
                                               Postal address
                                                P.O.Box 3606
                                                Robina Town Centre                                       Postcode   4230
                                               Licence Class or registration type (if applicable)

                                               ………………………………………………………………………………………………..
                                               Licence or registration number (if applicable)
                                                Reg Architect Qld 1325
                                                FPA Australia BPAD Level 3 practitioner 16935
7. Signature of appointed                      Signature                                            Date
   competent person                                                                                  15 June 22
This certificate must be signed by the
individual assessed by the building
                                                E J Bottcher
certifier as competent to give design-
specification help.

LOCAL GOVERNMENT USE ONLY
 Date received                                                           Reference Number/s




                  ELDON BOTTCHER ARCHITECT PTY LTD                        ©           15/06/22                       15

Page 16

                                       FIRE MANAGEMENT REPORT FM 5601




                                                    APPENDIX 5.2
                                                     SITE PLANS


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  16

Page 17

 

 

3901. 10N 111 TW aS alNSoaOus Oe IPOD Sg ONAN Se

NOILLVONdd¥ SNINNY Id

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE MANAGEMENT REPORT FM 5601

 

 

 

 

 

 

 

 

 

 

 

 

 

 

065¥801 9980 sucuse Bape

© sossatw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= moe 696L¢ OV'dd VaA ©GINALSIOIN
eWwOpULSY (ev eras; a TE WOODPIEMIM —syncrccssous
‘jeq anss| yuaund ey 2WLIGL OZ9L0EdS F LOT juauidojanag wun nINW fequapisey | PewennpleGemt EBiStoe om 2 z
equa ped au seq Mudd ielss300¥ 2
| SNOLLWAONSY = 3
“WioaWNOD Q
, JWNgaIS3S 3
G3SOdOUd - NVId SIS 89Gb GTO euOWUIod JENS YOINYD DLL aqua vrTvuLsn¥ 5
suey Bue sono Nowsaa oNIoTING a
BI areou wD]
va0a0t
uvaor i
HSIN]
382-02 LINN oo
aymouwel se \
‘080d 6_UNn| tt _
uve i] Kee
Taran y;
eS J
(0382-61 LINN. MY A/
LL

 

 

 

 

 

 

 

 

Seow

 

 

qaaz-at LINN

  

YOO14 SSOND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“ees i]

 

 

 

DOH LN

 

 

 

q3a2-91 LINN

82-0 LIND

 

 

 

 

‘snyois
5

 

iin BOO AGL)

 

a

 

 

 

 

 

 

 

 

 

6
air
g3az-S1 LINN gage 6 LIND
‘ovasenonaavo 08 WLOL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

wc cxsoaoud
ae ea sDydS CLO LYN
‘011405 g390u0Rd tevsmen us su 0

‘san omen ASOD | KOO.

sownuas

sonmana Then auyen yay
‘SNA 2 MOL water 101
‘3SNOdSau Gas0d0Ud SNOLWONTVO ALIS

 

 

 

 

 

 

 

 

 

 

 Tevannoa

 

 

 

 

 

 

 

sxeusasino
Sms TN

1LASYuLS HONNHD

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

15/06/22

©

ELDON BOTTCHER ARCHITECT PTY LTD

Page 18

                                       FIRE MANAGEMENT REPORT FM 5601




                                                APPENDIX 5.3
                                   BUSHFIRE HAZARD MAPPING


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  18

Page 19

                                       FIRE MANAGEMENT REPORT FM 5601




     Noosa Shire Council Bushfire Hazard Mapping


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  19

Page 20

                                           FIRE MANAGEMENT REPORT FM 5601




                                                   APPENDIX 5.4
                                   REGIONAL ECOSYSTEM MAPPING




ELDON BOTTCHER ARCHITECT PTY LTD      ©      15/06/22                  20

Page 21

                                       FIRE MANAGEMENT REPORT FM 5601




     State Fuel Load Tables




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  21

Page 22

                                        FIRE MANAGEMENT REPORT FM 5601




State Regional Ecosystem and Vegetation Hazard Class Tables




 ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  22

Page 23

                                        FIRE MANAGEMENT REPORT FM 5601




Regional Ecosystem Mapping of subject site




 ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  23

Page 24

FIRE MANAGEMENT REPORT FM 5601

 

 

25/01/2022 09:13:41
Lot: 4 Plan: SP301620

 

 

Rag

 

gad

danas

yas
PS

he:

 

Legend

Selected Lot and Plan

Category A or 8 area containing encangered regional ecosystems.
Category Aor B area containing of concer regional ecosystems
Category Aor B area thats @ least concern regional ecosystem
Category ¢ oF R area containing endangered regional ecosystems.
Category C of R area containing of concern regional ecosystems
Category G or R area iat Is a teastconcem regienal ecosystem
Category X area

Water

CDG

N

(ZA, Wetiandon the vegetation management wetlands map
Essent habat onthe essential heat map
Essential habitat species record

‘Wtercourses and dana

thd drainage features map
{Stream order shown as black numer agains taam where avaiable)

Highway
Connector
Street/Local Road

 

I1e 97

 

National Parks, State Forest and otter reserves
Other land parcel boundaries

 

features on the vegetation management watercourse

Vegetation Management Supporting Map

 

Queenstand
Government

N

A

140200 420860 700m

‘This product is projected into:
‘GDA 1994 MGA Zone 56

Labels or Essential Habitat are centred on the area of enquiry

Regional ecosystem linework has been compiled at a scale of 1:100 000,
cexceptin designated areas where a compilation scale of 1:50 000is
availabe. Linework should be used as a guide only. The positional
‘2ccuracy of RE data mapped at a scale of 1.100.000 is ~/- 100 metres,

Disclaimer:
‘While every care is taken to ensure the accuracy of this product, the
Department of Resources makes ro representatons or warranties about Is
‘accuracy, relly, empletenessor suitability fer any particuler purpose
‘and dieclaims all responsibilty anc all liability (including without limitation,
liability in negigence) forall expenses, losses, damages (including indirect
fr consequential damage) and costs which you might incur as result ofthe
produc! being inaccurate or incomplete in any way and for any reason,

 

 

‘Additional information may be required forthe purposes of land clearing or
‘assessment ofa reghnal ecosystem map of PMAV applicators. For
{urther information ge to the web ste: www. resources.qld.govau or contact
‘he Department of Resources,

Digital data for the vegetation management watercourse and drainage
feature map, vegetaton management wetlands map, essential habitat map
{and the vegetation management remnant and regional ecosystem map are
‘avalabe from the Queensland Spatal Portal at

hitp/lawn information qe. gov au!

Land parcel boundares are provided as locational id only.

(© The State of Queensland (Department of Resources), 2022

 

 

 

Page 2

 

ELDON BOTTCHER ARCHITECT PTY LTD

©

15/06/22 24

Page 25

 

25/01/2022 09:13:41
Lot: 4 Plan: SP301620

FIRE MANAGEMENT REPORT FM 5601

 

 

 

 

   

¢ )
SS

 

 

Legend

[7 seieces tot and an

HEE category A area (Vegetatonofsetsicomplnce notes VDees)
BE cote gory 8 area (Remnant vegetation)

[1 category ¢ area (High-value regrowtn vegetation)

[J] category Rare (Reet eprowh watercourse vegetation)

 

Water
‘Avea not categorised

‘Other land parcel boundaries

 

 

‘Category X area (Exempt clearing work on Frechold, Indigenous and Leasehold land)

N

A

 

This productis projected into:
GDA 1994 MGA Zone 56

000m

Regulated Vegetation Management Map

Disclaimer:
While every care is taken to ensure the accuracy ofthis product, the
Department of Resources makes no representations or warranties
about its accuracy, reliability, completeness or sulabilty for any
particular purpose and dclaims all responsibilty and al iabilty
(including without limitation, liabilty in negligence) fr all expenses,
losses, damages inclucing indirect or consequential damage) and
costs which you might incur as a resut ofthe product being inaccurate
or incomplete in any way and for any reascn.

Additional information required forthe assessmert of vegetation values

is provided in the accompanying "Vegetation Management Supporting map”

For further information goto the web sta: www resources qld.gov.au or
contact the Department of Resources,

Digital data for the reguleted vegetation management map is available from
the Queensland Spatial Portal at http www. information qld. gov au

Land parcel boundaries are provided as locational ald only.

This map is updated on a monthly basis o ensure new PMAVs are
included as they are approved

Goverment

The State of Queenslend (Department of Resources), 2022

 

 

 

 

Page 1

ELDON BOTTCHER ARCHITECT PTY LTD

©

15/06/22

25

Page 26

                                       FIRE MANAGEMENT REPORT FM 5601




                                                      APPENDIX 5.5
                                                    AERIAL PHOTOS


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  26

Page 27

                                       FIRE MANAGEMENT REPORT FM 5601




     Aerial Photo of site and surrounding areas




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  27

Page 28

                                        FIRE MANAGEMENT REPORT FM 5601




Site showing distance from Unit 13 to threat vegetation south of
Memorial Avenue




 ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  28

Page 29

                                        FIRE MANAGEMENT REPORT FM 5601




Site showing 100m line to west and Pottery Street




 ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  29

Page 30

FIRE MANAGEMENT REPORT FM 5601

v
oO
o
is
re]
is)
ad
2
ey
Cy

Pa

unit 13

 

ELDON BOTTCHER ARCHITECT PTY LTD © 15/06/22 30

Page 31

                                        FIRE MANAGEMENT REPORT FM 5601




Site photo showing 100m line to Memorial Avenue and including
development on southern section of adjoining lot to West




 ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  31

Page 32

                                       FIRE MANAGEMENT REPORT FM 5601




                                                    APPENDIX 5.6
                                                    SITE PHOTOS


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  32

Page 33

                                       FIRE MANAGEMENT REPORT FM 5601




        Western end of Memorial Avenue




        Driveway into Southern section of adjoining site to west
        and showing vegetation management




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  33

Page 34

                                       FIRE MANAGEMENT REPORT FM 5601




        Driveway into Southern section of adjoining site to west
        and showing vegetation management




        Waterway Vegetation




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  34

Page 35

                                        FIRE MANAGEMENT REPORT FM 5601




        View from Pottery Street across adjoining site to
        waterway




        Waterway vegetation




ELDON BOTTCHER ARCHITECT PTY LTD   ©      15/06/22                  35

Page 36

                                        FIRE MANAGEMENT REPORT FM 5601




        View from Pottery Street across adjoining site to
        waterway




        Adjoining site looking west




ELDON BOTTCHER ARCHITECT PTY LTD   ©      15/06/22                  36

Page 37

                                       FIRE MANAGEMENT REPORT FM 5601




         Waterway forming part of subject site




         Waterway forming part of subject site




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  37

Page 38

                                       FIRE MANAGEMENT REPORT FM 5601




        View from subject site looking west across adjoining site




        View from subject site looking west across adjoining site




ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  38

Page 39

                                       FIRE MANAGEMENT REPORT FM 5601




                                               APPENDIX 5.7
                                   COMPLETED OVERLAY CODE


ELDON BOTTCHER ARCHITECT PTY LTD   ©     15/06/22                  39

Page 40

                                                               FIRE MANAGEMENT REPORT FM 5601




       PERFORMANCE                  ACCEPTABLE OUTCOMES                    COMMENTS
       OUTCOMES
       PO1                          AO1.1
       Development maintains        Development which will materially      The proposed development is
       the safety of people         increase the number of people          not located within a medium or
                                    living or congregating on              high bushfire hazard area.
                                    premises, including reconfiguring
                                    a lot, is not located within a
                                    medium or high bushfire hazard
                                    area.

                                    AO1.2
                                    Development maximises setbacks
                                    from hazardous vegetation to           Setbacks from hazardous
                                    achieve an acceptable risk             vegetation is maximised to
                                                                           achieve an acceptable risk,
                                                                           demonstrated that only one
                                                                           building will be within 100m of
                                                                           threat vegetation
       PO2
       Bushfire mitigation          No acceptable outcome provided         The proposed development is
       measures do not                                                     situated within a cleared portion
       adversely impact on:                                                of the site and rehabilitation
            (a) Biodiversity                                               based on Low Threat
                 values,                                                   vegetation is required within the
                 connectivity,                                             water way corridor.
                 and ecosystem
                 functioning; and
            (b) The long-term
                 physical
                 integrity of
                 waterways,
                 wetland, and
                 areas of native
                 vegetation
       PO3                          AO3.1
       Development provides         Premises are connected to the          The premises will be served by
       an adequate water            reticulated water supply               reticulated water
       supply for firefighting
       purpose which is reliable,   OR
       safely located and freely
       accessible.                  AO3.2
                                    Where there is no available
                                    reticulated water supply, the
                                    premises has:
                                         (a) An accessible dam,
                                              swimming pool or water
                                              tank available for
                                              firefighting purposes with
                                              an onsite water volume
                                              of not less than 5,000
                                              litres; and
                                         (b) A water supply outlet
                                              pipe of 50 mm in
                                              diameter fitted with a
                                              standard fire brigade
                                              fitting connected to the
                                              water supply (other than
                                              where the water supply
                                              is in a swimming pool or
                                              dam)




ELDON BOTTCHER ARCHITECT PTY LTD                    ©             15/06/22                             40

Page 41

                                                                FIRE MANAGEMENT REPORT FM 5601



       PO4                         AO4.1
       Essential community         Development involving essential        The development does not
       infrastructure is able to   community infrastructure is not        involve essential community
       function effectively        located within a medium or high        infrastructure
       during and immediately      bushfire hazard area.
       after bushfire events.
                                   OR

                                   AO4.2
                                   Where located in a medium or
                                   high bushfire hazard area,
                                   development involving essential
                                   community infrastructure is
                                   designed to function effectively
                                   during and after a bushfire event
                                   in accordance with a Bushfire
                                   hazard Management Plan.
       PO5                         AO5.1
       Public safety and the       Hazardous materials are not            No hazardous material will be
       environment are not         manufactured or stored in bulk in      manufactured or stored in bulk
       adversely affected by the   a bushfire hazard area                 on site
       impacts of bushfire on
       hazardous materials
       manufacturing or storing
       on site
       PO6                         AO6.1
       Roads provide for easy      The road layout provides for           The access complies with “Fire
       and safe evacuation of      through -roads and avoids cul-de-      Hydrant and Vehicle Access
       premises and access by      sacs and dead-end roads                Guidelines for Residential,
       emergency services.                                                Commercial and Industrial Lots”
                                   OR                                     published by QFES and Qld
                                                                          Government.
                                   AO6.2
                                   The development has a perimeter
                                   road reserve with a minimum
                                   width of 20m and maximum
                                   gradient of 12.5%

                                   OR

                                   AO6.3
                                   Cul -de-sacs or no through roads
                                   are provided with fire trails or
                                   access easements, which are
                                   capable of being navigated by
                                   conventional vehicles and which
                                   link to through roads.

                                   AO6.4
                                   Safe access and egress is              The access complies with “Fire
                                   available at all times to all of the   Hydrant and Vehicle Access
                                   development for emergency              Guidelines for Residential,
                                   vehicles and personnel                 Commercial and Industrial Lots”
                                                                          published by QFES and Qld
                                                                          Government.

                                   AO6.5
                                   Where an emergency access              No emergency access point is
                                   point is required, it complies with    required
                                   the relevant works codes and
                                   PSP6 Engineering Design
                                   Standards




ELDON BOTTCHER ARCHITECT PTY LTD                    ©              15/06/22                          41

Page 42

                                                              FIRE MANAGEMENT REPORT FM 5601




       PO7                         AO.7
       Lot design and building     Each residential lot:
       siting minimises bushfire         (a) Includes a building          Complies
       hazard risk to people and             envelope, identified on
       property                              the plan of subdivision;
                                         (b) Is of sufficient size and    Access complies with “Fire
                                             shape to allow for           Hydrant and Vehicle Access
                                             efficient emergency          Guidelines for Residential,
                                             access to buildings for      Commercial and Industrial Lots”
                                             firefighting appliances      published by QFES and Qld
                                             (e.g., by avoiding battle-   Government.
                                             axe/hatchet lots and long
                                             narrow lots with long
                                             access driveways to
                                             buildings
                                         (c) Where more than              Complies
                                             2500m2 , achieves
                                             setbacks from hazardous
                                             vegetation in line with
                                             Bushfire Attack Level 29
                                             requirements as per AS
                                             3959; and
                                         (d) Is designed so that          Complies
                                             buildings and structures
                                             are sited in locations of
                                             lowest hazard within the
                                             lot and elements of the
                                             development least
                                             susceptible to fire are
                                             closest to the fire hazard
       PO8                         AO8.1
       Firebreaks and fire         Where development involves the         The site does not immediately
       access tracks provide:      creation of a new road and lots, a     adjoin threat vegetation with
            (a) Adequate           fire break is provided by providing    roads to the west and south
                access for         a cleared road reserve not less        providing access between
                firefighting and   than 20 metres wide and                adjoining site and threat
                other              maximum gradient of 12.5%              vegetation
                emergency          around the perimeter of the
                vehicles; and      subdivision, between the created
            (b) Adequate           lots and surrounding vegetated
                access for the     lands.
                evacuation of
                residents and      OR
                emergency
                personnel in an    AO8.2
                emergency          Fire access tracks are provided        N/A
                situation          between the created lots and           See comments above
                                   surrounding vegetated land that;
                                        (a) Have a cleared minimum
                                            width of 6m
                                        (b) Have a maximum
                                            gradient of 12.5%




ELDON BOTTCHER ARCHITECT PTY LTD                   ©             15/06/22                            42

Page 43

                                                   FIRE MANAGEMENT REPORT FM 5601



                               (c) Prob=vide unbroken
                                   access for fire fighting
                                   vehicles;
                               (d) Provide passing bays
                                   and turning areas;
                               (e) Are located within an
                                   easement that is granted
                                   in favour of Noosa
                                   Council and the
                                   Queensland Fire and
                                   Rescue Service.
                                                              Complies
                           AO8.3
                           Bushfire management measures
                           are carried out on the subject
                           property and not any adjoining
                           property.




                                                         APPENDIX 5.8
                                             SUPPORTING INFORMATION


ELDON BOTTCHER ARCHITECT PTY LTD         ©            15/06/22                 43

Page 44

                                                                        FIRE MANAGEMENT REPORT FM 5601



(NOTE: SOME OF THIS INFORMATION IS GENERIC AND NOT PROVIDED FOR APPROVAL
PURPOSES. IT IS ONLY PROVIDED FOR END USER KNOWLEDGE)

6.PROFILES

ELDON BOTTCHER

EDUCATION AND QUALIFICATIONS
Graduate Diploma in Design in Bushfire Prone Areas
University of Western Sydney
Diploma in Architecture
Queensland Institute of Technology
Certificate of Rural Fire Management                           OTHER BUSHFIRE RELATED COURSES AND
University of Southern Queensland                              TRAINING
Registered Architect                                           I.C.S./AIIMS (40 hr. course) in Incident Command
Queensland                                                     Systems
A+ Architect                                                   Certificate 4 (Workplace Training and Assessment)
Australian Institute of Architects                             RFSQ Level 1
FPA Australia Certified Practitioner (BPAD-Level 3-            RFSQ Level 2 (Officer)
16935)                                                         RFSQ Fire Management 1
Bushfire Planning and Design (BPAD-LEVEL 3),                   RFSQ Crew Leader
Alternate Solutions & DTS                                      Certificate II in Public Safety (Firefighting Operations)
                                                               Fire Weather 1
PROFESSIONAL MEMBERSHIPS                                       QELA Expert Witness Workshop 2020
Fellow
Australian Institute of Architects                             BUSHFIRE RELATED AWARDS
Member                                                         National Planning Award
Australian Institute of Emergency Services                     State Planning Award
Member                                                         Planning Institute of Australia
Australian Institute of Engineers Society of Fire Safety       Gold Coast Bushfire Management Strategy
Member                                                         (Co-Initiator and Member of Preparation Committee)
Queensland Environmental Law Association.
Member Board of Experts                                        Australian Government
Bushfire Building Council of Australia                         National Medal
Associate Member                                               Long and Distinguished Service to Fire fighting
Institution of Fire Engineers                                  Queensland Fire and Rescue Service
Corporate Member                                               Diligent and Ethical Service Medal + Clasp
Fire Protection Association of Australia                       Service to Fire fighting

PROFESSIONAL EXPERIENCE                                        Queensland Government
Director                                                       Australia Day Medallion
Eldon Bottcher Architect Pty Ltd since 1978                    Services to Rural Fire Fighting
Bushfire Assessment and Planning Consultant since              Queensland Government
1998                                                           Year of the Volunteer Medallion
Group Officer                                                  Services to Fire fighting
Albert Rural Fire Brigades Group                               UDIA
Queensland Fire and Rescue Service                             Best Consultancy Team Award in 2007.
Group Officer
Gold Coast Rural Fire Brigades Group                           SERVICES OFFERED
Queensland Fire and Rescue Service
Group Officer                                                  Bushfire management Reports
South East Regional Support Group
Queensland Fire and Rescue Service                             Bushfire Safety Engineering
Planning Officer
                                                               Bushfire Planning and Design
Gold Coast Rural Fire Brigades Group
Queensland Fire and Rescue Service
                                                               Bushfire Hazard Assessment
Member Practice Committee AIA Qld Chapter
BBCA representation to Australian Standards                    Alternative Solutions
Committee FP20 (AS 3959 & AS 5414 )
Life Member                                                    Expert Witnessing
Guanaba Rural Fire Brigade                                     (See Planning and Environment Court of Queensland
Member                                                         Determination
Clagiraba Rural Fire Brigade                                   File No. BD 624 of 2005 sections 28 to 35)

                                                               Continuing Professional Development Lectures

                                                               Tertiary Education Lectures and Tutorials

                                                               Town Planning Bushfire Codes for Local Authorities

                                                               Bushfire Burn Planning



  ELDON BOTTCHER ARCHITECT PTY LTD                         ©               15/06/22                                  44

Page 45

                                                     FIRE MANAGEMENT REPORT FM 5601



General consultancy relating to all aspects of
Bushfire




 ELDON BOTTCHER ARCHITECT PTY LTD                ©     15/06/22                  45

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.