                                         Figure 2: Site Images

We note the following:

   ●   Noosa Plan 1990:
          ○ Section 6.2.8.7 of the Planning Scheme allows the ability to modify planning scheme
              requirements if it is considered that such dispensation or modification is justified by
              having regard to the existing development in the area, topography or the like.
          ○ Section 4.4.4.1 of the Planning Scheme states that vehicular parking shall not generally
              exceed a gradient of 10%;
   ●   QDC MP1.3
          ○ A1(c) allows an open carport to be within the minimum road setback where:
                  ■ The aggregate perimeter dimension of walls, solid screens, and supports located
                      within the setback does not exceed 15% of the total perimeter dimension (along
                      the line of supports) of that part of the carport within the same setback. The
                      proposed aggregate perimeter dimension is <10% of the total perimeter
                      dimension (this includes 3 sides as per Figure 4 of QDC MP1.2 and all sides as a
                      comparison) (where 15% is allowed); and
                  ■ Whilst there is space beside the existing garage, as shown in Figures 1 and 2
                      above, there is no suitable location that does not require extensive earthworks
                      within a mapped landslide hazard area. The location within the turn bay is an
                      existing flat area.

Having regard to the Noosa Plan 1990, existing development in the area does not have any consistent
setbacks. It can be seen in Table 1 below that there are a number of existing structures within the
preferred 6m front setback requirement.




                                                                                                    3

Used in these records

About this file

File size
15.8 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Further Advice Response.pdf · 15.8 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.