07/2398 - SUPERSEDED Negotiated Decision Notice & copy sent to Referral Agencies [As Published] · 132007.2398
2007/2398
7 ADVISORY NOTES
The following Advisory Notes are for information purposes only and do not form conditions of
approval:
1 The applicant is advised that development contributions and infrastructure charges applicable
to this development approval have been based on the following Uses Class/ Uses and
applicable quantities:-
Existing Development Approved Development
Existing Use Class / Existing Approved Use
Approved Quantity
Use Quantity Class / Use
Stage 1 = 120 single beds + 21x 2 bed units
Stage 2 = 21x 2 bed units
Stage 3 = 29 x 2 bed units
1 Lot & house Stage 4 = 13 x 2 bed units
Multiple Housing -
Detached House + Type 3 - Retirement Stage 5 = 21 x 2 bed units
1 Vacant Lot & Special Needs
Stage 6 = 24 x 2 bed units
Stage 7 = 18 x 2 bed units
Stage 8 = 20 x 2 bed units
Stage 9 = 12 x 2 bed units
2. The applicant is informed that payment via credit card transaction will not be an acceptable
method of payment for development contributions conditioned in this permit or for
infrastructure charge notices issued separately.
3. The requirement for payment of infrastructure contributions has been assessed in accordance
with Council’s policy “Infrastructure Contributions (Charges) Rebates for Eligible Community
Organisations”. This approval is based on the organisation type and purpose of development
in accordance with Table 1 of the policy as detailed in the contribution condition of the
Development Permit.
4. The applicant is advised that a Compliance Permit for all plumbing and drainage works within
the boundaries of the development site shall be obtained from Council’s Plumbing Services
Section prior to obtaining a Development Permit for Building Works.
5. A separate loop of water main should be installed within the property boundary for domestic and
fire services. Fire hydrants and fire sprinklers are should be connected to the fire main. Fire hose
reels and the domestic supply to be connected to the metered domestic service.
6. The applicant is advised that this development may require the provision of fire hydrants and a
booster pump in accordance with the Building Code of Australia, and in consultation with
Queensland Fire Services to ensure suitable fire fighting infrastructure is provided. To this end
any necessary fire hydrants shall be clearly shown on the plans submitted for both Operational
Works and Building Works approvals and if a booster pump is deemed necessary, the plans
shall indicate where the fire truck is to be accommodated in order to provide boosting to the
water supply.
7. A Waste Management Plan shall be in accordance with Planning Scheme Policy No. 9 and
further, shall include the following information: -
The types of waste that will be generated from the activities approved within the
development.
Estimated volumes or tonnage of both recyclables and waste generated.
Methods to be used for dealing with garden waste.
Initiatives to minimize waste either by waste prevention, reduction, re-use or recycling.
17 of 31
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2398 - SUPERSEDED Negotiated Decision Notice & copy sent to Referral Agencies [As Published]Related documentApplication case desk ↗
About this file
- File size
- 645 KB (small file)
- File type
No other editions are linked here.