1.0 INTRODUCTION

1.1

1.2

Description of Development
The proposed site is subject to an application for a material change of use at Lots

1 & 2 RP903222 David Low Way, Peregian Beach. The development will involve
the construction of 5 office tenancies with ground level and basement carparking.

Pre-Development Site
The subject site is currently undeveloped, is sparsely vegetated and falls gently
to the north. It is located in the Eastem Beaches precinct of Noosa Shire.

2.0 STORMWATER MANAGEMENT STRATEGY

2.1

2.2

2.3

2.4

Hydrology
The site is located on the David Low Way, Peregian Beach, adjacent to the

Peregian Beach Bowls Club. The site is generally flat with surface levels ranging
from RL 10.0 m AHD to RL 11.0 m AHD. The proposed use of the site will not
alter existing catchments or detrimentally redirect surface flows.

Proposed Stormwater Drainage
The stormwater drainage system for the proposed development will be designed

in accordance with QUDM and AS3500 Part 5.

Runoff from as much of the extemal area of the development as is practicable
will be conveyed to landscaped areas for infiltration. Surface runoff external to
the building will be allowed to flow through landscaped areas as far as
practicable to allow infiltration to occur.

Runoff from the site will be discharged into a proposed new stormwater gully pit
to be located at the frontage of the site. From there a stormwater pipe will convey
discharge into the existing stormwater manhole some 25m north of the site on
the David Low Way as noted on drawing M3087-SWMP-01. The location and
alignment of this stormwater infrastructure will be detailed at the operational
works stage of design. As this system is under Council control it is proposed that
this is a lawful point of discharge.

Flows from Driveways
The runoff from the driveway will be directed onto adjacent unpaved areas where

practicable to allow for infiltration. The use of a grated drain constructed at the
bottom of the ramp will catch driveway runoff before it flows into the basement.

Stormwater Quality

It is proposed that low flows collected from the driveway will be dissipated over
unpaved areas for infiltration as much as practicable. Where runoff enters the
proposed grated drain, it will be treated by a gross pollutant trap prior to
discharge to the proposed stormwater pit at the frontage of the site.

The quality of the runoff from the development would meet the requirements of
Environmental Protection (Water) Policy ANZECC standards and Council’s Code
for Waterways and Wetlands.

Used in these records

About this file

File size
7.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_2689 - MCU - Commercial Business Type 1 - Office [As Published].pdf · 7.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.