2016008949 Approved Drawings - Signed
Attached to the e-mail Operational Works Application OPW16/0338.
2016008949
Nov 22, 2016
[OCR of page images]
2016
PLOTTED 14
EXISTING BUILDING WALL
‘ASSUMED SUSPENDED SLAB
REFER STRUCTURAL ENGINEERS
DRAWINGS.
EXISTING GROUND FLOOR GROUND FLOOR -RL 8.30 GROUND FLOOR- RL 8.30
APPROXIMATE EXISTING
‘COLUMNS REFER STRUCTURAL GROUND LINE
ENGINEERS DRAWINGS
ah
~ ~
‘O-— EXISTING SEWER TO BE
‘ABANDONED AND REMOVED
EXISTING BASEMENT BASEMENT - RL 5550 BASEMENT -RL 5.550
| 28
‘im CLEAR ZONE ASSUMED SLAB ON GROUND PROPOSED SEWER SS
ASSUMED FOOTINGS TYPICAL REFER STRUCTURAL ENGINEERS N50 PVC-M a ae ‘ASSUMED RETAINING WALL FOOTING
REFER STRUCTURAL DRAWINGS. aI aa REFER STRUCTURAL ENGINEERS DRAWINGS.
ENGINEERS DRAWINGS
[+ BORED PIERS REQUIRED EACH SIDE OF SEWER
7 coensewer q (TO STRUCTURAL ENGINEERS DETAILS)
PROP( TO GO MIN 0.3m BELOW INVERT LEVEL OF SEWER.
* DNt5O PVC -M Lggge Lag Sica TO ENSURE THE SEWER IS NOT LOADED BY THE
RETAINING WALL,
030
MN
% ANY FOOTINGS INSIDE THE SEWER'S
‘ZONE OF INFLUENCE MUST BE TAKEN
BELOW SEWER INVERT LEVEL TO
ENSURE THE SEWER IS NOT LOADED
SEWER CROSS SECTION
‘SCALE 150
SEWER CROSS SECTION
SCALE 1:50
@ Unitywater
APPROVED PLANS
File No: ..2916008949
Signed:
Dated:
WHILST EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION
PROVIDED IN THIS DRAWINGIDESIGN WAS ACCURATE AT THE TIME IT WAS
COMPILED, AS PART OF UNITYWATER’s “AS CONSTRUCTED" RECORDS, IT REMAINS
‘THE RESPONSIBILITY OF PROPERTY OWNERS AND THEIR CONTRACTORS,
SUB-CONTRACTORS, EMPLOYEES, SERVANTS AND AGENTS AS APPROPRIATE IN THE
CIRCUMSTANCES TO MAKE ALL REASONABLE EFFORTS TO ASCERTAIN THE PRECISE
LOCATION OF EXISTING INFRASTRUCTURE INCLUDING WATER MAINS, SEWERS AND.
DRAINS BEFORE UNDERTAKING EXCAVATION OR CONSTRUCTION WORK.
USERS OF THE INFORMATION SHOULD BE AWARE THAT SINCE THE ORIGINAL
RECORDING OF THE DEPTHS IN RELATION TO GROUND LEVELS, CHANGES MAY HAVE
OCCURRED AS A RESULT OF SUBSEQUENT WORK OR ACTIVITIES INVOLVING FILLING
OREXCAVATION. CONSEQUENTLY, UNITYWATER AND vT CONSULTING ENGINEERS
TAKES NO RESPONSIBILITY FOR ANY APPARENT ERROR OR INACCURACIES THAT
ARE SHOWN TO EXIST AS AT THE DATE INFORMATION WAS PROVIDED OR AT A
LATER DATE,
‘THE ABOVE ALSO APPLIES TO LOCATION AND DEPTH OF OTHER PUBLIC UTILITIES.
(CUENT SAE 150 DRAWN JC PROUECT 0B No
Descn AVT TEWANTIN - NOOSA RSL 16144
oa AHD cwecne _ AVT 1 MEMORIAL AVE, TEWANTIN QLD 4565
‘APPROVED DRAWING TITLE DRAWINGN REV
SEWER RETICULATION
: BUILD OVER SEWER SECTIONS C005 B
4.11.16] FOR APPROVAL ° at [Av
A [14-10-16] FOR APPROVAL ic [av
wey | one mate > [=| ENGINEERS
[email protected]
(07) 3172 8334
PO Box 26, Carina
aL 4152
vtce.com.au_
z
SCALE 1:50
NOT FOR CONSTRUCTION