Construction nominated 10 be constructed destroyed in bushfire have
10 Flame Zone and BAL 12.5 been the result of ember
in accordance with AS3959: attack. Appropriate building
2009 Bu ding Construction construction is one of the
in Bushfire Prone Areas. most important elements to
be considered to prevent
the buildings themselves
being destroyed in
bushfires. The nominated
BAL’s are approp ate to the
site and meet the
requirements of
AS3959:2009 method A.
Landscaping No requirement nominated Detailed landscaping
provisions for bushfire
management have been
nominated. Irrigation system
nominated.
Maintenance No requirement nominated Maintenance mandated and
prescriptions for landscape
maintenance outlined.
It is considered that the proposal provides bushfire management solutions which when used
in combination are superior to the measures required in the previously endorsed fire
management plan by James Warren Associates. The proposal also adopts several
measures besides building construction measures to achieve suitable outcomes as outlined
in the table above.
Although the proposed fire control line is not trafficable by rural fire appliances being 1-2m
wide as opposed to 4-5m wide, the control line is accessible to fire appliances (hose lines &
personnel) and still ensures the following functional requirements as per the purpose of the
trail:
Access for direct suppression of low intensity fires;
. Access for implementation of controlled burning;
. Access for undertaking back burning where designated safe to light fires by the
incident controller; and
. Access for maintenance of the adjoining radiant heat shield fencing and retaining
wall.
The control line is finished close to ’at grade’ with the adjoining bush land surface fuels and
near surface fuels being practical for the performance of fire fighting activities. Please refer
to the sections provided by Reitsma.
Suitable appliance deployment locations have been nominated which will be free of
obstacles such as landscaping, fencing etc. The appliance deployment areas are located
directly at the top of the entry points to the fire control lines. The deployment locations
enable QFRS to back up appliances and run hose lines directly along the fire control lines.
The appliances are then positioned in a forward direction for rapid deployment elsewhere.
Many QFRS appliances have been and will continue to be fitted with automatic hose reels
with Archimedes Screws which enable ’make up’ to be undertaken very quickly.
The stationary location of the appliance also free up the driver to assist in the fire fighting
operations such as manning the pump as opposed to needing to return to the vehicle to
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU11/0254 Response to information requestRelated documentApplication case desk ↗
About this file
- File size
- 39.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.