Council archive · source document
06/2689 - Response to request for further Information [As Published] · 132006.2689
Very large file (19.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
31/05 2007 16:19 FAX 61 7 54495354 Noosa Shire Council (0003/0006 5.1. In this regard it is noted that the present proposal contains, blind comers and blind aisles with no provision for vehicles to turn around. As such, designated turning bays must be provided and it is recommended that they be at least 3m wide (to allow ease of-access and departure) and at least 5.4m long. To this end: Q One turing bay should be provided adjacent to the proposed stairs located at the south-eastern corner of the basement (space number 30), and a One turning bay should be provided on the eastern side of the basement, immediately to the north of the proposed tank (space number 22). 5.2. The proposed driveway ramp that provides access to the carpark needs to be amended as: a It appears that two laneways will need to be separated by a cental median, with each lane having a minimum width of 3.9m measured between kerbs. Q The proposed ramp grades must be determined by the inside radius of the ramp (i.e. where the ramp grades will be steeper) not the middle of. the ramp. Q Headroom between the ramp and the entrance to the basement carpark must be designed such that vehicles will not hit the upper level, as this will require changes to the upper level and/or the driveway grades. 5,3. Amend the proposal plan such that clear access is available to all stairs - Gases. In this regard it is noted that clear access cannot be obtained to the proposed stair at the south-eastern corner of the upper level carpark. A clear passage of at least 1.5m in width should be available to the stairs, free of any carparking spaces or wheel-stops that would impede pedestrian movements. 5.4. Given the overall size of this development and the number of separate tenancies proposed, please provide at least 2-disabled car park spaces on site. The abovementioned issues outline some of the problems that have been noted and in this regard the applicant will need to review AS2890.1 in detail to ensure the car park and driveway ramps are designed correctly. Vehicle Access 6. The proposed separated entry. and exit for the development, similar to that which exists for the existing house on site, is not suitable for a development of this scale and likely traffic generation and would result in countless conflicts between vehicles and pedestrians using the footpath especially given that the driveway has a width of approximately 25m, which coincides with the pedestrian path. The angle of the entry and exit would also cause vehicles to enter and leave the site at faster speeds, which is not conducive for pedestrian safety and nor are adequate sight lines available. Award Winner - Australian Clean Beach Challenge 2004 Litter Prevention :
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/2689 - Response to request for further Information [As Published]Related documentApplication case desk ↗
About this file
- File size
- 19.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.