‘Detention Volume = (Imax — Qmax)tc
(b) Area D (0. 0282ha Roof)
Rainwater Tank Reuse Sizing
Total’ persons/day using toilet = = 200 x 0.0282 (ha of roof space) :
=6 persons .
“Water Demandfor Toilets” = 6 x 40L
ue oo . = 240tIday
Water Demand for External Water Use . , . a = 2000 x 0.0282 thas of iigatea 2 landscaping) .
, . : vi = S7Liday ue
“TotalDemand = - oe = 297Uday
- Tank Reuse Capacity. oo ° : . = Ten.times the daily use me
. So =2,970L | ey aw)
Adopt 24 x5,000L Tank’ ,
’ Rainwater Tank Detention Storage Sizing
Pre Q2.. mot = FCIA® . le
: = 0.00278 x 0.629 x 190 x 0.0282
_ = 0,0074m"s
‘Post Qe . = FCIA-
=0: 00278 x 1x 163 x 0.0282 ,
=0.0128m'/s :
(Qe post -Q2 pre ~ Reuse).t.”
{0.0128 — 0:0074 — 0.0005)300
1.47?
Allow 1, OOOL detention in.a 5, OOOL tank, (20%) :
, Equivatent Detention Storage Pipe Outlet Orifice Diameter of Rainwater Tank
~ Bo = _ Ques ‘
: CaV2gH
_ Where:
Ao ° = Orifice aréa (m”) .- .
Ques _ = Design discharge (m P75) ~ .
> Cg. = Orifice discharge coefficient (0.6)
“H = = Depth of water above the centroid of the orifice e(m)
» Ao = Ques
CaV2gH -
Us 0.0074
0.6 N19.6. & x04
= 0. 004m?
Adopt; an Equivalent Tank Outlet Pipe Diameter of 75mm
22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published]Related documentApplication case desk ↗
About this file
- File size
- 16.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.