4.3.2 Business Uses Code
Table 14-5 For all Business Uses
114.711 Effects Of Use Six scErN EEE “Rea.
fh
ken hicks
Proposa
ET PE EE AP
ana azsocratay
Electricity infrastructure
O} The development does not adversely
impact on existing or future electricity
supply infrastructure;
AND
O2 All uses and works maintain an
adequate safe distance from electrical
infrastructure including substations,
Overhead powerlines, power poles and
transformers.
Sit No solution provided
$2.1 Development for uses adjacent
to or within 50m of an existing
electricity substation incorporates
noise attenuation measures to
mitigate noise impacts; and
$2.2 Buildings and structures
{including swimming pools, sheds,
tennis courts and outbuildings) are
not constructed under overhead
electricity transmission lines, or within
electricity easements.
Complies.
The proposal will not hinder
existing or future supply. of
electricity.
N/A.
The site is not located within 50m
of an existing electricity substation
or under overhead electricity
transmission lines, or within
electricity easements.
14.18 Amenity sma nt ttt Risen dil Feat
SUONT BERN RT ef
rs aay
fl aden HES
Noise
O03 Development is designed and sited
to avoid noise emissions that
unreasonably diminish the amenity of the
area or surrounding uses.
No solution provided
Complies.
The proposal is sited within a
designated industrial area and
thus a majority of the surrounding
uses are highly compatible. The
design achieves a 10m setback to
the adjoining residential boundary
(west). A solid fence will be
constructed along the boundary
and the industrial building has a
solid wall with no openings to
ensure no detrimental noise
impacts result.
Mechanical plant and equipment and
storage areas
O04 Mechanical plant and equipment
(including air conditioning equipment)
and storage areas are designed and
located to—
@) avoid adverse visual impacts when
viewed from the street and adjoining
properties; and
e) visually integrate with the building
design.
$4.1 Mechanical plant and
equipment are—
f) located more than 2m from any
property boundary;
g) where located at ground level,
screened by fencing 1.5m in
height or dense vegetation of at
least 1.5m in width incorporating
grouped trees and shrubs with
maximum separation distance of
Im measured from the centre of
the tree or scrub; and
are visually integrated into the line
and plane of the building and roof
design and do not project beyond
the height or width of the building
when viewed from the street and
adjoining properties:
AND
$4.2 For Industrial business and Retail
business Type 3, materials stored
outside of a building do not exceed
4m in height or half the height of the
on-site buildings whichever is the
greater.
h
Complies.
This will be applied ot detail
design.
Not applicable as Industrial
Business Type | and 2 uses are
proposed.
Safety and security
O5 All property boundaries are clearly
identifiable with public and private
spaces clearly defined.
$5.1 Boundaries are identified by
such means as -
i) fencing; or
j) changes in surface materials or
levels; or
k} landscape treatments.
Complies.
Boundaries are identified by the
Utilisation of effective landscaping
treatments.
March 2007 Development Permit for Material Change of Use for Industrial Business Type 1 and 2 Page 17 of 23
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published]Related documentApplication case desk ↗
About this file
- File size
- 16.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.