6

The proposed landscaping treatments will produce a pleasant working environment and
improve the amenity of adjoining properties through effective screening. The proposed
development will provide a pleasant and well presented landscaping treatment to Gateway
Drive.

Further details of the Landscaping Code will be addressed within a subsequent application for
an Operational Works Development Permit.

4.3.4 Engineering Works Codes

The Driveways and Carparking Code requires a rate of 1 space per 50m2 of use area for
Industrial Business Type | and 1 space per 50m? for the first 500m2 and 1 space per 100m?2 of
use area in excess of 500m? for Industrial Business Type 2. While it is expected that less than 50%
of the use will be Type 1, carparking has been provided for the entire development at the rate
of 1 per 50mz2. In this regard based on 4850m2 of industrial use, 95 carparking spaces have
been provided. It is noted that the proposal plan provides an additional 10 car parks which
are intended to facilitate a cafe on the site, which will be subject to a separate development
application.

A dedicated loading bay for a single unit truck is provided onsite, with sufficient manoeuvring
area for a semi-trailer. Due to the nature of the use comprising small industrial tenancies
frequent semi-trailer usage of the site is unlikely.

Tne driveway design and construction will be in accordance with applicable Australia
Standards and AUSTROADS.

Bicycle parking provision has been provided at the rate of 1 per 100m? (ie. 50 bike parks). End

of trip facilities (ie. | shower and locker space) will be provided within each tenancy.

Site works, filling and connection to services will be generally in acciradnce with that
approved in 2005 under file 23074DA.

4.3.5 Biodiversity Overlay Code

An ecological assessment of the site has been undertaken by Pedersen Biological and
Environmental. This report establishes that the majority of the site is casurina regrowth with the
exception of vegetation to be retained within the proposed buffer area along the northern
boundary and north-eastern corner. No significant flora or fauna was recorded. The sites
environmental significance has been previously assessed in detail with file no 23074DA. The
assessment included referral to the EPA, DPI&F and DNRW. The parameters and requirements
for environmental protection established with the Negotiated Decision Notice issued 15
December 2005 for file 23074DA have been maintained with the current proposal.

nh

ken hicks

ano agsoceatee

 

March 2007 Development Permit for Material Change of Use for Industrial Business Type 1 and 2 Page 22 of 23

Used in these records

About this file

File size
16.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published].pdf · 16.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.