Council archive · source document
07/0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published] · 132007.738
Very large file (16.0 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Ecological Assessment, Bushland Drive Noosaville -— 15th April, 2003 (Wildlife) Regulation 1994. This species is not recorded from within the development envelope and is therefore not expected to be directly impacted by the present proposal. This species is known elsewhere to proliferate in man-made drains and other disturbed semi-aquatic environments. The present level of proposed development is not expected to critically threaten the long-term presence of this species within the vicinity provided . hydrology in the fringing marine wetland to the north is not altered and provided no less than the recommendations presented here and the performance standards listed in Appendix 'B are adhered to. A single taxa, (Pteropus poliocephalus) considered Vu/nerable under the Environment Protection and Biodiversity Conservation Act 1999 (EPBCA) is recognised from the site (Chapter 4.3). Due to the small extent of vegetation proposed to be cleared, this wide- ranging and relatively common species (within southeast Queensland) is not expected to be significantly disadvantaged by the presently proposed development and no development application is anticipated to be needed under the EPBCA. Development of this site will require significant earthworks and filling to the north and east within the development. Retaining walls are preferable here to battered banks. Battered banks provide an disturbed environment suitable to colonisation and subsequent spread of environmental weeds. Battered banks are also generally landscaped with species considered “appropriate” by the landscaper, rather than correct, locally occurring taxa which are harder to acquire commercially. This often further compromises the integrity of existing native vegetation by introducing foreign species to the site. Retaining walls should be permanent and should not be constructed of materials such as treated woods that may leach or harm the environment. Retaining walls should be so placed that the footings are wholly contained within the site and that adjacent off-site vegetation is not disturbed or disrupted during the construction process. Disturbed soils at the base of the wall and adjoining open space vegetation to the north should be mulched with weed-seed free mulch and be considered for revegetation with marine couch or similar where appropriate. Planting density should be adequate to ensure rapid cover of disturbed soils to a level equal to adjoining natural vegetation. Provision should be made for adequate ongoing husbandry of revegetation plantings to ensure target coverage levels are achieved. Care should be taken here in ensuring that fertiliser applications do not impact existing vegetation or water quality, particularly within RE12.1.1 vegetation that adjoins. If appropriate locally occurring species are selected, they will be adapted to the existing level of soil fertility and will need minimal additional applications. Stormwater and tailwater management for the site should ensure no change to the existing watertable and drainage regime. This particularly applies to persistent tailwaters and swimming pool discharge and to greasetrap discharge from the proposed restaurant. PEDERSEN BIOLOGICAL AND ENVIRONMENTAL PaGE 30 of 70
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published]Related documentApplication case desk ↗
About this file
- File size
- 16.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.