Nee

 

Ecological Assessment, Bushland Drive Noosaville — 15th April, 2003

limited to Burhinus grallarius (Bush Thick-knee). This process is disruptive to the natural
ecology and should be avoided where possible by reducing the level of light played onto
remnant vegetation and ensuring that all private and public lighting is directed
downward rather than laterally or upwards, into the remnant vegetation canopy.

6.5 POTENTIAL ADVERSE IMPACTS ON THE QUALITY OF WATERS
IN THE UNNAMED CREEK TO THE SOUTHWEST AND WETLANDS TO
THE NORTH OF THE SITE DURING BOTH CONSTRUCTION AND
OPERATIONAL PHASES.

Erosion and stormwater-borne pollution such as litter, vegetative propagules of
environmental weeds, greenwaste and dissolved pollutants and nutrients are
unacceptable by-products of urbanisation and commercial development. Significant
polluting (in solution) events are more likely to occur during low flow situations rather
than flood flows. Low volume sustained tailwaters are a common by-product of urban
and commercial development. These tow flows can carry pollutants in solution at critical
or chronic concentrations. Every effort should be made to contain and/or allow retention
and treatment time for urban tailwaters before they are allowed to enter the existing
waterway. Ideally no tailwater should discharge from the site to the north.

Development of this site will require significant earthworks and filling. It is imperative
that spoil heaps, material heaps and cut surfaces are managed to prevent polluting
runoff during rain and storm events. From an environmental perspective, stormwaters
(as distinct from low-flow tailwaters) are responsible for sedimentation and trash
dispersal. Stormwater-borne trash can often include propagules of serious environmental
weeds, while unnatural sedimentation can significantly alter the ecology of waterways
and wetlands such as those of the study site. These impacts are commonly mitigated
through implementation of Structural Best Management Practices (BMPs) such as
temporary and permanent Sediment Traps and Silt fences, Trash Racks, Filter Strips and
Swales and in more severe cases by Infiltration Trenches and by Water Quality Control
Ponds or Bioremediation cells. The present site is not extensive in area and will be
unable to accommodate some of the larger structural BMPs. It will be critical to
adjoining wetlands that sediment retention or treatment devices are effective and well
maintained. It is also important to ensure that silt fences and similar are removed once
ground cover or permanent structural BMPs are in place. It is becoming increasingly
common to find old silt fences remaining in place long after construction phase is
complete. These fences are not only visually polluting but interfere with the movement
of smaller wildlife.

Considering the proximity of wetland and fish habitat of Lake Doonella to this
development, it is recommended that structural retaining walls are used to contain fill
rather than battered banks. Structural retaining walls present a far lower erosional risk
than battered banks. Retaining walls should be so placed that the footings are wholly
contained within the site and that adjacent off-site vegetation is not disturbed or
disrupted during the construction process. Retaining walls should be permanent and
should not be constructed of materials such as treated woods that may leach or harm
the environment. Disturbed soils at the base of the wall and adjoining open space
vegetation to the north should be mulched with weed-free mulch and be considered for
revegetation with marine couch or similar where appropriate.

 

PEDERSEN BIOLOGICAL AND ENVIRONMENTAL PAGE 32 of 70

Used in these records

About this file

File size
16.0 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published].pdf · 16.0 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.