Ecological Assessment, Bushland Drive Noosaville — 15th i
Potential Impact
Possible reduction in regional
biodiversity through clearing on proposed
Performance standards — No less
than the following
Control measures — No less than
the following
Monitoring
Auditing and Reporting
Corrective action
ia) Tdeally no Wss in regional
biodiversity ~ Under the present proposal
regional widide diversity is expected to be
retained through conservation of open space
areas within the site and through provision
for wildlife corridors and continued
connectivity with contiguous vegetation,
1b) RE 12.1,1 vagetation within the site
is crilical to regional biodiversity and must be
conserved. Other vegetation within the
proposed devalapment is nol considered
significant on a bioregional basis and within
the context of this report, may be cleared
without significant impact to regional
biodiversity.
10) Extreme care should be taken not
to adversely affect native vegalation adjacent
to the site either directly through civil works,
through physical disturbance or indirectly
through alteration to nutrient of water
regimes.
1) Minimal disturbance or dearing
{other than recognised weed species) should
be undertaken in vegetation proposed to be
retained. DNR will need to be consulted
‘before weed eradication within endangered
{RE12.1.1) vegetation is undertaken. Weed
removal within this association may require
formal approval from DNR.
te) All construction activity should be
excluded from the proposed open space
area, inducing parking and maintenance of
vehicles and temporary or tong-term storage
‘of equipment and/or materials.
1) The proposed open space area
should be adequately protected from
polluting run-off and unnatural
sedimentation during construction phase.
ig) Durning constuction, the developer
‘should ensure that ail contractors and site
personnel are aware of the extent and
control measures for protection of standing
native vegetation to be retained.
tn) ‘During operational phase, the
responsible entity should regulaity (yeasty)
inspect proposed open space areas for
damage, weed invasion or unnatural loss of
vegetation,
PEDERSEN BIOLOGICAL AND ENVIRONMENTAL
Pace 55 of 70
ti)
It is the developer's responsibility
to identify personnel responsible for
control measures.
y) Standing native (conserved)
vegetation should be checked by qualified
persannel at completion of the
Construction phase to ensure the integnity
of these elements within the parameters
defined by this plan and to recommend
remediation works if required,
1k) No formal reporting should
foreseeably be required relative to this
potential impact,
wy ‘Vegetation inadvertently lost,
despite due care and attention should be
replaced as per the paragraph below.
1m) Where ground within conserved,
vegetation associations is laid bare through
weed removal or other necessary activities, 1¢
should be replanted to locally occurring
hers, shrubs or vines (as listed in Appendix
A) and mutched with appropriate weed-seed
free mulch, Where possible, consideration '*
should be given to the use of local
Provenance species, however this may be
impractical where seed parents are limited in
aumber or where there is a risk of reducing
genetic divessity of the population by
protiferation of cuttings from a single seed
parent.
in) Vegetation lost through natural
senescence need not be replaced
perfunctority.
lo) Any actions identified as adversely
affecting retained or conserved vegetation or
vegetation adjacent to the study site, ether
during construction or aperational phases,
should be stopped immediately,
HL
hi
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0738 - MCU - Industrial Business Type 1 & Industrial Business Type 2 - Mintgrove Pty Ltd [As Published]Related documentApplication case desk ↗
About this file
- File size
- 16.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.