Original source · versioned page text
16-001014-100(A)
From the archive Proposal Plans 1 of 2.zip, inside Operational Works Application OPW16 /0203 - 1 of 4. File date in the archive: 2016-09-12 16:19.
PALM LAKE RESORT - COOROY 19 TRADING POST ROAD, COOROY DRAWING INDEX ROADWORKS AND DRAINAGE 16-001014-100 DRAWING INDEX AND LOCALITY PLAN 16-001014-101 OVERALL LAYOUT PLAN 16-001014-102 ROADWORKS AND DRAINAGE LAYOUT PLAN 16-001014-103 ROADWORKS AND DRAINAGE NOTES AND DETAILS 16-001014-104 BULK EARTHWORKS LAYOUT PLAN 16-001014-105 BULK EARTHWORKS NOTES, DETAILS AND SECTIONS 16-001014-106 EROSION AND SEDIMENT CONTROL LAYOUT PLAN 16-001014-107 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS 16-001014-108 ROAD 2 LONGITUDINAL SECTION 16-001014-109 ROADS 11, 12 AND 13 LONGITUDINAL SECTIONS AND TYPICAL SECTIONS 16-001014-110 CARPARK SETOUT AND DETAILS 16-001014-111 SURVEY SETOUT LAYOUT PLAN 16-001014-112 STORMWATER DRAINAGE CATCHMENT PLAN SHEET 1 OF 2 16-001014-113 STORMWATER DRAINAGE CATCHMENT PLAN SHEET 2 OF 2 16-001014-114 STORMWATER DRAINAGE LONGITUDINAL SECTIONS SHEET 1 16-001014-115 STORMWATER DRAINAGE LONGITUDINAL SECTIONS SHEET 2 16-001014-116 STORMWATER DRAINAGE LONGITUDINAL SECTIONS SHEET 3 16-001014-117 STORMWATER DRAINAGE Q10 CALCULATIONS TABLE 16-001014-118 STORMWATER DRAINAGE Q100 CALCULATIONS TABLE 16-001014-119 STORMWATER DRAINAGE STRUCTURE DETAILS SHEET 1 OF 2 16-001014-120 STORMWATER DRAINAGE STRUCTURE DETAILS SHEET 2 OF 2 SEWERAGE RETICULATION 16-001014-200 SEWERAGE RETICULATION NOTES AND LOCALITY PLAN SE EGE CUS ISL Ay 16-001014-202 SEWERAGE RETICULATION LONGITUDINAL SECTION SHEET 1 OF 2 16-001014-203 SEWERAGE RETICULATION LONGITUDINAL SECTION SHEET 2 OF 2 16-001014-210 SANITARY SERVICES SITE PLAN WATER SUPPLY 16-001014-300 WATER SUPPLY NOTES AND DETAILS 16-001014-301 WATER SUPPLY LAYOUT PLAN STORMWATER QUALITY 16-001014-400 WATER QUALITY NOTES AND DETAILS 16-001014-401 SOUTHERN BIORETENTION BASIN LAYOUT PLAN 16-001014-402 SOUTHERN BIORETENTION BASIN SECTIONS 16-001014-403 CENTRAL BASIN LAYOUT PLAN OF 3 OF 3 OF 3 16-001014-404 CENTRAL BASIN SETOUT PLAN SHEET 1 OF 4 16-001014-405 CENTRAL BASIN SETOUT PLAN SHEET 2 OF 4 16-001014-406 CENTRAL BASIN SETOUT PLAN SHEET 3 OF 4& 16-001014-407 CENTRAL BASIN SETOUT PLAN SHEET 4 OF 4 CENTRAL BASIN SECTIONS SHEET 1 OF 2 CENTRAL BASIN SECTIONS SHEET 2 OF 2 CENTRAL BAIN DETAILS NORTHERN BASIN LAYOUT PLAN NORTHERN BASIN SECTIONS NORTHERN BASIN DETAILS 16-001014-408 16-001014-409 16-001014-410 16-001014-411 16-001014-412 16-001014-413 STAGE 2 CONSTRUCTION HOLD POINT PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL VERIFY LEVELS OF ALL EXISTING CROSSINGS AND CONNECTION POINTS. CONSTRUCTION HOLD POINT ONCE THE BASE OF MANHOLES, INSPECTION PITS, GULLIES AND FIELD INLETS FOR STORMWATER DRAINAGE AND SEWER RETICULATION HAVE BEEN POURED, FURTHER CONSTRUCTION SHALL NOT PROCEED UNTIL THE SUPERINTENDENT AND OR ENGINEER HAVE INSPECTED THE WORKS FOR FINISHED LEVELS AND APPROVED CONSTRUCTION TO CONTINUE. CONSTRUCTION NOTE THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH: - STORMWATER QUALITY MANAGEMENT REPORT - CALIBRE CONSULTING - 16-001014-01A - SEPTEMBER 2016 - STORMWATER MANAGEMENT CONSTRUCTION AND MAINTENANCE - CALIBRE CONSULTING - 16-001014-02A - SEPTEMBER 2015 - TRAFFIC IMPACT ASSESSMENT - CALIBRE CONSULTING - B14158ERO1C - DECEMBER 2014 - ACOUSTIC ASSESSMENT REPORT - ASK CONSULTING ENGINEERS - 7617RO1VO2 10/02/16 - ELECTRICAL CONSULTANTS PLANS - ELECTRO TECHNICAL CONSULTANTS - K3173 DRAWING SET (ENERGEX PROJECT NUMBER - S0500378) - LANDSCAPE ARCHITECT PLANS - TBA No. OF LOTS =: 1 No. UNITS = 65 AREA OF SITE = 2.9 ha RP DESCRIPTION LOT 1 ON RP215922 PARISH OF TEWANTIN COUNTY OF MARCH DATUM LEVEL P.S.M. 24974 RL 110.614 AHD —s LOCALITY PLAN N.T.S. U.B.D. REF: AUSTRALIAN CITY STREETS MAP: 4 | GRID: R20 N.S.C. REF NO. MCU15/0111 & REC15/0031 raat [once [oeawn] _ pate SCALE (METRES T TACROFL Wo. CENT a ae AMENDMENT DETAILS DEsION SURVEYOR: ML_SURVEYS =v tye ae 38 Leybourne Street, Chelmer QLD 4068 PALM LAKE WORKS PTY LTD coma | DRAWING INDEX AND a5 — Mob: 0412 744 223 E: [email protected] J & J LOCALITY PLAN i es alc DRAWN cHecK PROJECT Mo. j Calibre Consulting (QLD) Pty Ltd eal ie soot ( ie PALM LAKE RESORT (e||\0( ee = SIE Tdephone 07 3895 3444 Focsinle 07 3895 3400 ‘go'900} siF FOR & ON BEHALF OF CALIBRE CONSULTING (QLD) PTY LID STAGE 2 CONSULTING riba Canbura Maboune Syny Singapore Suntica Coot Lic 4064 16-001014-100 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.