Skip to the record
Every meeting, every word.

Original source · versioned page text

7. Attachment F - Bushfire Hazard Assessment

of 47

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

2/16/23, 3:44 PM

Flamesol - powered by FPA Australia

&

FPA | MES

AUSTRALIA

Calculated February 16, 2023, 4:44 pm (MDc v.4.9)

199 Beddington Rd South-east fire run SFR

Inputs
Fire Danger 48
Index
Vegetation Forest

classification

Understorey
fuel load

Total fuel
load

Vegetation
height

Effective
slope

Site slope

Flame width

Windspeed

Heat of
combustion

Flame
temperature

31 t/ha

35 t/ha

n/a

3.06 °

4.53 °

49.58 m

n/a

18,600 kJ/kg

1,200 K

Rate of
spread

Flame length

Flame angle

Elevation of
receiver

Fire intensity

Transmissivity

Viewfactor

Minimum
distance to <
40 kW/m2

Minimum
distance to <
29 kW/m2

Minimum
distance to <
19 kW/m2

Minimum
distance to <
12.5 kW/m?

Minimum
distance to <
10 kW/m2

Outputs

2.2 km/h

18.53 m

61.53 °, 65.53 °,
70.53 °, 73.53 °,
75.53 ° & 83.53 °

6.57 m, 6.46 m, 6.15
m, 5.59 m, 5.24m&
1.59 m

39,880 kW/m

0.852, 0.835,
0.8139999999999999,
0.795, 0.785 & 0.736

0.4184, 0.3096,

0.2083, 0.1403,

0.1138 & 0.0303

19.8 m

24.9m

32.6 m

41.6m

47m

tools.flamesol.com.au/MDc_output.php?CALCTITLE=199+Beddington+Rd+South-east+firetrun+SFR&EFFECTIVESLOPE=3.06&SITESLOPE=4... 1/2
Log in to download the original file

7. Attachment F - Bushfire Hazard Assessment.pdf · 3.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.