Original source · versioned page text
7. Attachment F - Bushfire Hazard Assessment
2/17/23, 10:58 AM Flamesol - powered by FPA Australia & FPA | MES AUSTRALIA Calculated February 17, 2023, 11:58 am (MDc v.4.9) 199 Beddington Rd SW fire run SFR Inputs Fire Danger 48 Index Vegetation Forest classification Understorey fuel load Total fuel load Vegetation height Effective slope Site slope Flame width Windspeed Heat of combustion Flame temperature 31 t/ha 35 t/ha n/a 9.5° 4.2° 53.12 m n/a 18,600 k3/kg 1,200 K Rate of spread Flame length Flame angle Elevation of receiver Fire intensity Transmissivity Viewfactor Minimum distance to < 40 kW/m2 Minimum distance to < 29 kW/m2 Minimum distance to < 19 kW/m2 Minimum distance to < 12.5 kW/m2 Outputs 3.43 km/h 26.55 m 57.2 °, 61.2 °, 65.2 °, 70.2 °, 72.2 ° & 82.2 ° 9.19 m, 9.210000000000001 m, 8.960000000000001 m, 8.619999999999999 m, 8.289999999999999 m & 4.43 m 62,193 kW/m 0.839, 0.821, 0.8, 0.78, 0.77 & 0.723 0.4242, 0.3146, 0.2124, 0.1432, 0.116 & 0.0309 26.8 m 32.9m 42m 52.7m tools.flamesol.com.au/MDc_output.php?CALCTITLE=199+Beddington+Rd+SW+fire+run+SFR&EFFECTIVESLOPE=9.5&SITESLOPE=4.2&VEG... 1/2