4 GENERAL FIRE MANAGEMENT MEASURES
4.1 Introduction

A range of general management procedures are to be implemented for the Open Space
areas. These will ensure that fire regimes important for the survival of significant fauna
are achievable.

4.2 Fire Breaks

A fire break will be located at the interface of each fire management unit to provide
physical separation of management units during fuel reduction burns and to provide
continuous access for fire fighting vehicles (FIGURE 5). The fire breaks will:

e have a minimum cleared width of 6 m (i.e. all vegetation will be cleared);

e have a maximum gradient of 1 in 4;

e be constructed and maintained to prevent erosion and provide continuous access
for fire-fighting vehicles;
utilise existing tracks wherever possible; and
allow for vehicle access at least every 200 m.

A fire break is shown as bisecting the drainage line in the southern portion of the site
(FIGURE 5). The vegetated drainage line provides habitat for identified significant
species; therefore, fire break design within this habitat will be sensitive to these species.
Tran (2002) recommends the construction of a culvert or an invert' for cross-drain tracks
for general use. These structures may be narrower (i.e. less than 4 m in width) to retain
corridor and habitat values.

Fire breaks will also be maintained at the interface of fire management units and
development, where appropriate. Where clearing is required for these fire breaks, buffer
width will be of sufficient width and are to be determined at the operational works stage.
Bushfire management will not rely on the removal of natural vegetation within 0S2, 053,
0S4, OS6 or any other area which is otherwise to be protected. The Consultancy Bureau
(2003) suggests a buffer of 20 m be located at the development interface, and may consist
of fire-retardant vegetation (e.g. rainforest plants, etc.) as an alternative to cleared
areas.

' Inverts are cross drainage structures that maintain the trafficability of the fire break. They may
be constructed with a V or U shaped bases. Ensure cross fall will drain the base and outlet drains to
a stable vegetated area (Tran 2002).

 

Q06030/AM/FIREMP/RW4 JAMES WARREN & ASSOCIATES PTY LTD 10

Used in these records

About this file

File size
2.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_1242 - Fire Management Plan [As Published].pdf · 2.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.