07/1242 - Fire Management Plan [As Published] · 142007.1242
Plans and drawings: the text below has words only, no drawings.
a Noosa Shire Business Centre - Fire Management Plan 4 GENERAL FIRE MANAGEMENT MEASURES 4.1 Introduction A range of general management procedures are to be implemented for the Open Space areas. These will ensure that fire regimes important for the survival of significant fauna are achievable. 4.2 Fire Breaks A fire break will be located at the interface of each fire management unit to provide physical separation of management units during fuel reduction burns and to provide continuous access for fire fighting vehicles (FIGURE 5). The fire breaks will: e have a minimum cleared width of 6 m (i.e. all vegetation will be cleared); e have a maximum gradient of 1 in 4; e be constructed and maintained to prevent erosion and provide continuous access for fire-fighting vehicles; utilise existing tracks wherever possible; and allow for vehicle access at least every 200 m. A fire break is shown as bisecting the drainage line in the southern portion of the site (FIGURE 5). The vegetated drainage line provides habitat for identified significant species; therefore, fire break design within this habitat will be sensitive to these species. Tran (2002) recommends the construction of a culvert or an invert' for cross-drain tracks for general use. These structures may be narrower (i.e. less than 4 m in width) to retain corridor and habitat values. Fire breaks will also be maintained at the interface of fire management units and development, where appropriate. Where clearing is required for these fire breaks, buffer width will be of sufficient width and are to be determined at the operational works stage. Bushfire management will not rely on the removal of natural vegetation within 0S2, 053, 0S4, OS6 or any other area which is otherwise to be protected. The Consultancy Bureau (2003) suggests a buffer of 20 m be located at the development interface, and may consist of fire-retardant vegetation (e.g. rainforest plants, etc.) as an alternative to cleared areas. ' Inverts are cross drainage structures that maintain the trafficability of the fire break. They may be constructed with a V or U shaped bases. Ensure cross fall will drain the base and outlet drains to a stable vegetated area (Tran 2002). Q06030/AM/FIREMP/RW4 JAMES WARREN & ASSOCIATES PTY LTD 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1242 - Fire Management Plan [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.