5. Electricity Design · MCU19/0117
LEGEND
ADJOINING SHEET 2 SYMBOL DESCRIPTION
SC1457713
OAD
R 1 STATION NUMBER
U1457717
A CH EXISTING OH CONDUCTOR
BE PROPOSED OH CONDUCTOR
HV and LV POLE
POLE TRANSFORMER
HV AIR BREAK OPEN
HV AIR BREAK CLOSED
LV DISC LINK OPEN
LV DISC LINK CLOSED
U1457720
SHEET 2 HV POLE TERMINATION
LV POLE TERMINATION
SHEET 1 GROUND STAY
EXISTING UG CABLE
PROPOSED UG CABLE
EXISTING SUPPLY PILLAR
PROPOSED SUPPLY PILLAR
LINK PILLAR
PADMOUNTED TRANSFORMER
EXISTING CABLE IN CONDUIT
kV)
C L3 C (11 PROPOSED CABLE IN CONDUIT
U1457721 240 A MEN (EARTH GROUND STAKE)
660
E ELECTRICAL CABLE MARKER
CUSTOMER SWITCHBOARD
PIT
32 S70 STREET LIGHT
0
CFL 32 STREET LIGHT
TREE
)
kV
LV SWITCH FUSE UNIT
( 11
NEW BUILDING
C
L3
0A
24
OAD
R
SED
O CONSTRUCTION NOTES
OP
)
PR
C( 11kV 1. ALL BENDS INSTALLED ON 125mm RETICULATION
C AL 3 CONDUITS MUST BE 1830mm RADIUS UNLESS OTHERWISE
240 SPECIFIED.
660
2. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL
CONDUITS AS SHOWN IN CIVIL WORK SCHEDULE.
LOCALITY MAP STANDARDS AND SPECIFICATIONS
SCALE 1:4000
THIS WORKS PLAN IS TO BE READ IN CONJUNCTION AND
COMPLY WITH THE FOLLOWING ENERGEX MANUALS AND
SPECIFICATIONS:
- UNDERGROUND DISTRIBUTION CONSTRUCTION MANUAL
RTH
C 120mm EA
(11kV)
240 AL 3C FOR DETAILS OF ADDITIONAL TRENCH CROSS-SECTIONS,
*
(11kV)
40
REFER TO ENERGEX UNDERGROUND DISTRIBUTION
240 AL 3C CONSTRUCTION MANUAL.
UG SERVICES INFORMATION
UNDERGROUND SERVICES SHOWN ON THIS WORKS PLAN
30°
IN THE VICINITY OF PROPOSED EXCAVATION WORKS ARE
INDICATIVE ONLY.
240 AL 3C (11kV)
240 AL 3C (11kV)
CONSTRUCTION PERSONNEL SHALL REQUEST ON-SITE
240 AL 4C (LV)
IDENTIFICATION AND LOCATION OF EXISTING BURIED
C SERVICES FROM THE QUEENSLAND DIAL BEFORE YOU DIG
630
SERVICE. PH:1100 FAX:1300 652 077 (A MINIMUM OF TWO DAYS
TH
E AR V) NOTICE IS REQUIRED)
U2044033 mm (11k REFER JOB No: XXXXXXXX.
120 3C
AL
6 240
57
30°
0 43 SURVEY DETAILS
U2
C
THE PROPOSED SUBSTATION AND 2m WIDE CABLE EASEMENT
40 MUST BE SECURED IN FAVOUR OF ENERGEX.
EMAIL: [email protected]
SC2043570 PRINCIPAL'S SURVEYOR TO PEG ALL ROAD CORRIDORS
PRIOR TO CONSTRUCTION AND AFTER CONSTRUCTION TO
PROVE ACCURACY OF ASSET INSTALLATION.
577
043 4C (LV)
U2 240 AL V)
C 3C (11k
240 AL
120
10
0m
m
CO
ND
UI CONDUIT CROSS SECTION -
TS
FOOTPATH & ROADWAY
*
17
DENOTES CLASH
ENERGEX HV 600 FOOTPATH
750 ROADWAY-MINOR
CABLE WITH POOL
SITE PLAN BATTER TC TC
DETAIL A DETAIL N DETAIL D
10 0 10 20 30 40 50 METRES
NOTE: 5mm PROTECTION COVER STRIP REQUIRED WHEN
NOT IN ALLOCATED ENERGEX UG ALIGNMENT.
SCALE 1:1000 AT A1
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - APPROVED: AUSPOWER CONNECT
AC0727
A ORIGINAL 07/08/2019 CONTACT FOR CONSTRUCTION ENQUIRIES. Auspower Connect Pty Ltd Mark Bain Constructions Pty Ltd ENERGEX OH 3.0m PARENT PROJECT NO. - ONE DWELLING PROJECT NO.
Mark Bain ENERGEX UG 0 - 0.9m WORK REQUEST NO. - & WAVE POOL SCALE: 1:1000
PO Box 531
0412 711 151 STREETLIGHTS - LOTS 1 UNIT ENERGEX PROJECT NO.
Buddina, QLD 4575 ELECTRICAL RETICULATION
[email protected] COMMS REFER DBYD
Mob 0419 707 166
[email protected]
PROJECT MANAGER DETAILS GAS - CANCELLING LOTS 500 ON SP215779 APPROVED DATE: 07/08/2019 CONCEPT PLAN
TBA
Mark Bain Constructions Pty Ltd HP GAS - D.A - CHECKED: J McKenna
ABN 74 166 366 883
Mark Bain WATER REFER DBYD LOCAL AUTHORITY Noosa Council DESIGNER: B Bernie
This drawing is the property of Auspower Connect Pty Ltd and 90 BEACH ROAD
0412 711 151 STORMWATER REFER DBYD UBD REF - PHONE: 0419 707 166
must not be used, retained or copied without written permission
NOOSA NORTH SHORE ISSUE NO. A SHEET 1 OF 2 A1
[email protected] SEWER REFER DBYD PEGGED On Request ISSUE DATE:
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
LEGEND
SYMBOL DESCRIPTION
1 STATION NUMBER
EXISTING OH CONDUCTOR
PROPOSED OH CONDUCTOR
HV and LV POLE
POLE TRANSFORMER
HV AIR BREAK OPEN
HV AIR BREAK CLOSED
LV DISC LINK OPEN
LV DISC LINK CLOSED
3
15 HV POLE TERMINATION
7 53
P LV POLE TERMINATION
GROUND STAY
EXISTING UG CABLE
73 1kV) PROPOSED UG CABLE
0(1
/3.0 EXISTING SUPPLY PILLAR
3-7
PROPOSED SUPPLY PILLAR
LINK PILLAR
P753152 PADMOUNTED TRANSFORMER
EXISTING CABLE IN CONDUIT
PROPOSED CABLE IN CONDUIT
MEN (EARTH GROUND STAKE)
E ELECTRICAL CABLE MARKER
CUSTOMER SWITCHBOARD
159 11kV) PIT
0(
/3.0 S70 STREET LIGHT
3-7
CFL 32 STREET LIGHT
TREE
P302372
32 L V )
SP6738 C(
5 AB LV SWITCH FUSE UNIT
1- 9
49 P753151
3-7/3.00(11
kV)
D
R OA
H
AC
BE
)
1kV
L 3 C (1
C A
240
660
U1457719
9
12
12
0
AL
4C
(L
V)
SC1457713
U1457717
ADJOINING SHEET 1
SITE PLAN
10 0 10 20 30 40 50 METRES
SCALE 1:1000 AT A1
ISSUE DESCRIPTION DATE AUSPOWER CONNECT IS THE FIRST POINT OF DEVELOPER DETAILS ALIGNMENTS WORKS COORDINATOR - APPROVED: AUSPOWER CONNECT
AC0727
A ORIGINAL 07/08/2019 CONTACT FOR CONSTRUCTION ENQUIRIES. Auspower Connect Pty Ltd Mark Bain Constructions Pty Ltd ENERGEX OH 3.0m PARENT PROJECT NO. - ONE DWELLING PROJECT NO.
Mark Bain ENERGEX UG 0 - 0.9m WORK REQUEST NO. - & WAVE POOL SCALE: 1:1000
PO Box 531
0412 711 151 STREETLIGHTS - LOTS 1 UNIT ENERGEX PROJECT NO.
Buddina, QLD 4575 ELECTRICAL RETICULATION
[email protected] COMMS REFER DBYD
Mob 0419 707 166
[email protected]
PROJECT MANAGER DETAILS GAS - CANCELLING LOTS 500 ON SP215779 APPROVED DATE: 07/08/2019 CONCEPT PLAN
TBA
Mark Bain Constructions Pty Ltd HP GAS - D.A - CHECKED: J McKenna
ABN 74 166 366 883
Mark Bain WATER REFER DBYD LOCAL AUTHORITY Noosa Council DESIGNER: B Bernie
This drawing is the property of Auspower Connect Pty Ltd and 90 BEACH ROAD
0412 711 151 STORMWATER REFER DBYD UBD REF - PHONE: 0419 707 166
must not be used, retained or copied without written permission
NOOSA NORTH SHORE ISSUE NO. A SHEET 2 OF 2 A1
[email protected] SEWER REFER DBYD PEGGED On Request ISSUE DATE:
Used in these records
5. Electricity Design.pdfRelated documentApplication case desk ↗
About this file
- File size
- 517 KB (small file)
- File type
No other editions are linked here.