Original source · versioned page text
Waste Management Code
WASTE MANAGEMENT CODE
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
Waste separation
O1 S1.1 Complies with the Probable Solution
Development that generates several classes of Construction, operational and demolition works The development will comply with the relevant
waste is designed so waste is collected, stored and are planned and managed in accordance PSP1130; planning scheme policy.
disposed of in a safe and ecologically sustainable AND
manner29
S1.2 Complies with the Probable Solution
Adequate area is provided for on-site for the The existing waste storage will provide for
collection and separate storage of recyclable, non- recycling.
recyclable, vegetative and hazardous materials in
their specific waste streams during construction,
operational and demolition works;
AND
O2 S2.1 Complies with the Probable Solution
Waste storage areas provide for adequate Waste storage areas allow for the separate storage The existing waste storage area will provide for
separation of all recyclable and non-recyclable of different waste materials for reuse or recycling recycling.
materials. by
a) providing sufficient area to store all recyclable
material and recycling containers required, and
b) sign posting the types of waste stored.
Design and location of waste storage areas
O3 S3.1 Complies with the Specific Outcome
Waste storage areas are located so that they are Waste storage areas are designed and maintained in The existing waste storage area is appropriately
convenient and safe to use and provide for accordance with PSP 9; design.
convenient and safe collection by service vehicles; AND
AND
29 Any proposal for the disposal of liquid trade waste to Council s sewer must be in accordance with Noosa Council s Environmental Health Section s Trade Waste Policy.
30 PSP 11 requires Waste Management Plans to be prepared as part of certain types of development applications to ensure proper consideration is given to waste minimisation, segregation and
reuse.
Waste Management Code Page 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 3 pages
Page 2
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
S3.2 Complies with the Probable Solution
Waste storage areas are designed and located so The existing waste storage area is easily accessible
they and convenient to use. The waste storage will be
a) are easily accessed and convenient to use; able to collected.
b) have unobstructed access for the collection of
the waste by service vehicles;
c) provide for sufficient space for safe entry and
exit and servicing by Council s contractor
without the need for manual handling;
d) are clear of carparking bays, loading bays and
similar areas;
e) are clear of footpaths and pedestrian access;
f) are capable of being serviced by the collection
vehicle without impeding traffic flow; and
g) have a level area provided for the storage of
waste and recyclable materials in standard waste
containers; and
AND
S3.3 Complies with the Probable Solution
For uses that do not comprise a caretaker s The site will have central management.
residence or central management, the maximum
distance between waste storage areas and the
kerbside is
a) for Multiple housing Type 3 40m;
b) for other uses 70m; and
S3.4 Complies with the Probable Solution
Pathways used to transport bins The development will be designed appropriately
a) have a maximum grade of 1:15; and for the movement of bins.
b) are free of steps, stairs or other impediments;
AND
Waste Management Code Page 2
Page 3
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
O4 S4.1 Complies with the Probable Solution
The location and methods of waste storage Waste storage areas are The waste storage is suitably located and is set back
minimises any adverse impacts on adjoining or a) integrated with the building design, where over 2m from the side and rear boundaries. The
nearby properties; possible; storage area is screened. Suitable conditions can be
AND b) setback a minimum of 2m from side and rear imposed on the development to minimise impact
property boundaries; on neighbouring developments.
c) screened so that bins are not visible from
neighbouring properties or passing vehicular
and pedestrian traffic; and
d) not located directly adjacent to dwelling units on
the site on neighbouring properties;
AND
O5 S5.1 Complies with the Probable Solution
Waste storage areas are designed for ease of Waste storage areas are constructed of The waste storage area is existing.
maintenance and ease of access for cleaning; impermeable, durable and non-textured materials
and surfaces so that they are easily cleaned;
AND
S5.2
A minimum distance of 0.5m2 distance is provided
between and around waste storage bins to allow
for manoeuvring and washing of bins.
AND
O6 S6.1 Complies with the Probable Solution
Waste storage areas provide a safe and secure No solution provided. The waste storage area is designed appropriately.
environment for users through
a) appropriate siting and access;
b) the provision of lighting; and
c) restricting access to the general public by
making the area clearly identifiable as private
space (eg. through landscaping, change of
paving material or fencing, rather than locking
the area.
Waste Management Code Page 3
Page 4
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
Water management for waste storage areas
O7 S7.1 Complies with the Probable Solution
Waste storage areas are designed to contain S7.1 The waste storage area The waste storage area is designed appropriately.
and appropriately dispose of leakage from bins and a) is bunded and graded so that washwater and bin
wastewater from bin washing. leakage are drained to the sewer or an on-site
effluent disposal system via a gully within the
storage area;
b) has a bund wall with a maximum height of
100mm;
c) is serviced by a conveniently located hosecock
and backflow prevention device, and connected
to a water supply; and
d) is roofed or otherwise covered if the storage
area is
i) more than 1m2; or
ii) storing wet waste; or
iii) storing other waste with a high potential to
cause pollution if washed or leaked from the
bins, including waste oil or putrescibles.
Waste Management Code Page 4