Council archive · source document
049_Duplex_27 Grant St Noosa - Construction Issue C · MCU21/0020.01
Very large file (25.8 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 23, section 1. The text section number identifies this passage in the reader.
custom garage tilt door
not included in door schedule - refer
to elevation view and 3D renders custom garage tilt door
D-09 D-10
D-22 D-23
D-07
D-08
not included in door schedule - refer
to elevation view and 3D renders
ZERO THRESHOLD
DRAINS AT DOORS
D-05 D-06 D-11 + D-12
W-12 W-14 ACO DRAINS BY
AWS
W-11 W-13
D-17
D-18
D-19
D-20
D-21 D-24
D-15
D-16
D-13
D-14
D-03 D-04
D-01
D-02
4 Section Detail
Threshold Drain Detail 1:5
W-07 W-08
W-17 W-18
W-21 W-25
D-26
D-25
W-22 W-26 W-05 W-03 W-04 W-06
W-23 W-27 Plan
LOWER LEVEL - DOOR & 1 : 125
W-24 W-28
WINDOW PLAN
Number Height Width Head Height Type Comments
D-11
section detail #3 on this sheet
section detail #3 on this sheet
D-12
window schedule - refer to
window schedule - refer to
casements not included in
casements not included in
Mark Width Height Type Comments W-03 2400 2100 2400 Aluminium frames fixed glass panel
W-04 2400 2100 2400 Aluminium frames fixed glass panel
D-01 820 2040 VJ profile swing door W-05 2400 600 2400 Aluminium framed glass louvres
D-02 820 2040 VJ profile swing door W-06 2400 600 2400 Aluminium framed glass louvres
D-03 820 2040 VJ profile swing door W-07 600 1810 2400 Aluminium glass XO slider
D-04 820 2040 VJ profile swing door W-08 600 1810 2400 Aluminium glass XO slider
Plan D-05 820 2040 VJ profile swing door W-11 1500 800 2400 Aluminium framed glass louvres
3 D-06 820 2040 VJ profile swing door
GROUND LEVEL - DOOR & 1 : 125 W-12 1500 800 2400 Aluminium framed glass louvres
CON.21 D-07 820 2040 Solid Core - VJ profile swing door - Exterior
WINDOW PLAN W-13 1500 800 2400 Aluminium framed glass louvres
D-08 820 2040 Solid Core - VJ profile swing door - Exterior W-14 1500 800 2400 Aluminium framed glass louvres
D-09 1800 2100 2 Panel Robe Door - VJ profile W-17 2400 750 2400 Aluminium framed glass louvres
D-10 1800 2100 2 Panel Robe Door - VJ profile W-18 2400 750 2400 Aluminium framed glass louvres
D-11 4730 2400 W-21 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
D-12 4730 2400 W-22 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
OPERABLE
CASEMENT D-13 1000 2100 Custom aluminium framed glass swing door - single lite W-23 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
1400
SHUTTERS D-14 1000 2100 Custom aluminium framed glass swing door - single lite W-24 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
D-15 820 2040 VJ profile swing door W-25 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
Powdercoated
D-16 820 2040 VJ profile swing door W-26 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
aluminium frame
and blades D-17 1676 2100 2 Panel Robe Door - VJ profile W-27 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
D-18 1465 2100 2 Panel Robe Door - VJ profile W-28 600 900 2400 Aluminium framed 2-bay glass louvres (frosted)
REFER TO DETAILS D-19 1465 2100 2 Panel Robe Door - VJ profile W-29 1420 567 Velux Skylight
3000
1 & 2 ON DRAWING D-20 1676 2100 2 Panel Robe Door - VJ profile
1000
W-30 1420 567 Velux Skylight
DRAINAGE PLAN
CON.076 D-21 2400 2400 Signature Sliding Door (100mm)
REFER ROOF
W-31 1420 567 Velux Skylight
D-22 2400 2400 Signature Sliding Door (100mm) W-32 1420 567 Velux Skylight
Ground Floor Level D-23 2400 2400 Signature Sliding Door (100mm)
RL 17.764 m W-33 1420 567 Velux Skylight
D-24 2400 2400 Signature Sliding Door (100mm) W-34 1420 567 Velux Skylight
3 Section D-25
D-26
820
820
2400
2400
Aluminium glass swing door - single lite
Aluminium glass swing door - single lite
W-35 1420 567 Velux Skylight
CON.21 1 : 50 W-36 1420 567 Velux Skylight
Operable Casements
No. Description Date
H Approval Issue I 27/07/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty DOOR & WINDOW DRH
I
J
Approval Issue J
Construction Issue A
18/08/2021
08/10/2021
049 As indicated
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd PLAN
www.dennishillarchitect.com
K
L
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022 CON.21
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 11/03/2022 2:58:11 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
049_Duplex_27 Grant St Noosa - Construction Issue C.pdfRelated documentApplication case desk ↗
About this file
- File size
- 25.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.