Rooftop Level
RL 23.784 m
Upper Level
RL 21.084 m 6
4 CON.34
3
Velux skylights CON.34
CON.34
flush plasterboard raftered
raftered roof to ceiling - rafters to
engineers specification Upper Level
engineers specification
RL 21.084 m
Upper Level
shadowline recessed
RL 21.084 m
cornices
flush plasterboard
raftered ceiling - rafters
plasterboard
shadowline recessed skirting to engineers
balustrade
specification
Garage Level shadowline recessed
RL 18.384 m
Garage Level
RL 18.384 m cornices
Ground Floor Level
RL 17.764 m
shadowline recessed
Ground Floor Level skirting
RL 17.764 m
suspended
plasterboard ceiling Garage Level
RL 18.384 m timber framed landing
to engineers
specification
flush plasterboard Ground Floor Level
RL 17.764 m suspended
Lower Level suspended ceiling
RL 14.664 m concrete slab
compact fill to cabinetry fitout by client
engineers specification 7
footings and retaining to CON.34
engineers specification
2 Section core-filled blockwork
retaining wall to
CON.09 Section 1 1 : 100 engineers specification
timber stair landing
Rooftop Level Lower Level
RL 23.784 m RL 14.664 m
trussed roof to
manufacturers specification
5 footing and retaining to
engineers specification Lower Level
CON.34
RL 14.664 m
Upper Level
RL 21.084 m 3 Section footing and retaining to
CON.34 Section 1 - Callout 1 1 : 50 engineers specification
suspended
plasterboard ceiling
Colorbond roofing,
timber framed landing to fascias, barges and
engineers specification flashings in colour 'Basalt' 5 Section
Garage Level Upper Level CON.34 Section 2 - Callout 1 1 : 50
RL 18.384 m RL 21.084 m
Ground Floor Level
RL 17.764 m wool batt insulation
painted FC soffit
suspended
suspended plasterboard ceiling
plasterboard ceiling 4 Section
selected timber stair CON.34 Section 1 - EAVE DETAIL 1 : 25
Colorbond roofing,
Lower Level fascias, barges and
RL 14.664 m flashings in colour 'Basalt' wool batt warm LED strip light plasterboard finish
insulation installed into recess
EasyVJ cladding
Section
footings and retaining to
7 Section
1 engineers specification suspended
plasterboard ceiling CON.34 Section 2 - FLOOR DETAIL 1 : 25
CON.09 Section 2 1 : 100
6 Section
CON.34 Section 2 - EAVE DETAIL 1 : 25
No. Description Date
A Construction Issue A 08/10/2021 Project number Scale at A3
Project Client Drawing Drawn by
dennishillarchitect 27 Grant Street, Brown Rooster Pty BUILDING DRH
B
C
Construction Issue B
Construction Issue C
28/10/2021
11/03/2022
049 As indicated
mobile: 0438 20 55 66 | [email protected] Noosa Heads Ltd SECTIONS
www.dennishillarchitect.com CON.34
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 11/03/2022 2:58:26 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
049_Duplex_27 Grant St Noosa - Construction Issue C.pdfRelated documentApplication case desk ↗
About this file
- File size
- 25.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.