RG Strategic                                                                               #70250009-ENAC-RPT01-R1
Dolphin Backpackers – 14-16 Duke Street, Sunshine Beach                                              21 October 2025
Noise Impact Assessment

4.4          Summary of noise goals
Table 5 presents the adopted limiting criteria for this assessment.

                                               Table 5. Adopted limiting criteria


                                                                                                   Noise limit, dBA
                                                     Compliance             Noise
          Noise source          Receptor type
                                                        location        descriptor, dB
                                                                                           Day           Eve          Night


  Variable noise sources,
            including:          Sensitive land
                                                                                          42 [1]        40 [2]        34 [2]
       Carpark movements        uses, includes:        At façade         LAeq,adj,1hr
                                                                                         (35 + 7)
         and commercial           Residence
            deliveries


        Continuous noise        Sensitive land
       sources, including:      uses, includes:        At façade         LAeq,adj,1hr     37 [2]        35 [2]        29 [2]
      Fixed mechanical plant      Residence


           Variable and          Commercial
        continuous noise           sensitive            Indoors          LAeq,adj,1hr     45 [1]        45 [1]        45 [1]
             sources              receptors

[1]
      Limiting criterion adopted from EPP (Noise) 2019 – Acoustic Quality Objectives.

[2]
      Limiting criterion adopted from EPP (Noise) 2008 – Controlling Background Creep.

Where indoor noise criteria are applicable, indoor levels have been converted to equivalent
outdoor levels to enable direct comparison with façade predictions at the nearest sensitive
receptors. This conversion assumes that windows are wide open, with an attenuation of 7 dBA
through the building façade. This amount of reduction is considered to be conservative.




Live It Acoustics                                                                                                     Page 12

Used in these records

About this file

File size
7.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

App B - Acoustic Report.pdf · 7.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.