App B - Acoustic Report · 132008.299.02
RG Strategic #70250009-ENAC-RPT01-R1
Dolphin Backpackers – 14-16 Duke Street, Sunshine Beach 21 October 2025
Noise Impact Assessment
5.7.4 Fixed Mechanical Plant
Mechanical plant associated with the development is expected to include air-conditioning systems
for dormitory rooms and a kitchen exhaust system. At the time of reporting, final equipment
selections were not available.
Indicative noise levels of plant were therefore modelled as follows:
• Air-conditioning units: Modelled as point sources located 0.5 m above each finished floor
level adjacent to each room. Each unit was modelled with a sound power level of 63 dBA
Leq, representing a typical small-medium sized air-conditioning unit.
• Kitchen exhaust fan: A single point source was incorporated into the noise model 1.0m
above the finished roof level of the shared kitchen. A sound power level of 80 dBA Leq
was utilised, representing a typical kitchen exhaust fan discharging via rooftop ductwork.