                                                     least 300 millimetres above
                                                     the Defined flood event
                                                     (DFE).
                                                     OR
                                                     AO16.2                                     AO16.2 Not Applicable
                                                     Where the DFE has not been                 The proposal is not located in
                                                     modelled for the area, the                 the Flood Hazard Area.
                                                     finished floor level of
                                                     habitable rooms is at least
                                                     500 millimetres above the
                                                     highest recorded flood.
                                                     Editor's Note - The QDC mandatory
                                                     provisions MP3.5 also apply to the
                                                     construction of buildings in flood
                                                     hazard areas.
      PO17                                           No acceptable outcome                      AO17 Not Applicable
      Underground car parking areas                  provided                                   The proposal is not located in
      are designed to drain and                                                                 the Flood Hazard Area.
      function safely during a flood
      event and power failure.
      Editor's note - Basements should have
      flood immunity above the 1%AEP
      defined flood event with alternative
      means to mechanical pumping used to
      achieve such immunity.
      Major Electricity Infrastructure & Substations
      PO18                             AO18.1                                                   AO18.1 Complies
      Development is sufficiently      Development including any                                The proposal is appropriately
      separated from major electricity sensitive land uses is at least:                         located away from
      infrastructure and substations   (a) 50 metres from a                                     substations and transmission
      to minimise the likelihood of          transmission substation;                           line easements.
      nuisance or complaint.           (b) 10 metres from any
                                             other substation; and
                                       (c) 30 metres from a
                                             transmission line
                                             easement.
                                       AO18.2                                                   AO18.2 Complies
                                       Habitable buildings are not                              The proposal is not located
                                       located within an easement                               within an easement for a
                                       for a distribution line.                                 distribution line.
      PO19                             AO19                                                     AO19 Not Applicable
      Development is located and       Noise emissions do not                                   The proposal is for a Dwelling
      designed to avoid or minimise    exceed 5db(A) above                                      House and does not involve
      noise nuisance from the use of background noise level                                     infrastructure resulting in
      infrastructure.                  internal to a habitable building                         noise emissions exceeding
                                       measured in accordance with                              the requirements of AS1055.
                                       AS1055.




Plan A Town Planning Pty Ltd              Unit 4, 134 Constance Street, Fortitude Valley Q   p 07 3846 0807        abn 17 634 960 937
                                          4006
Town Planning & Development Consultants   PO Box 13 Fortitude Valley Q 4006                  e                     www.planatownplanning.com.au
                                                                                             [email protected]

Used in these records

About this file

File size
10.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

241220 9-512 David Low Way, Castaways Beach Minor Change.pdf · 10.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.