"          TOWN PLANNING REPORT                                                                                                 Ab
                        :                                                                                                    ken hicks

                      Specific Outcomes                        Probable Solutions                       Proposal
                                                       impacts; and
           O2 All uses and works maintain an           $2.2 Buildings and structures
           adequate safe distance from elecirical      {including swimming pools, sheds,
           infrastructure including substations,       tennis courts and outbuildings}
           overhead powerlines, power poles and        are not constructed under
           transformers.                               overhead electricity transmission
                                                       lines, or within electricity
                                                       easements.

           Noise
           O3 Development is designed and sited to     No solution provided                Complies — The development will
           avoid noise emissions that unreasonably                                         not result in any adverse noise
           diminish the amenity of the area or                :                            emissions.
           surrounding uses.
           Mechanical plant and equipment and
           storage areas                                                                   Complies - Mechanical plant and
           04 Mechanical plant and equipment           $4.1 Mechanical plantand     -      equipment will be appropriately
           (including air conditioning equipment)      equipment are—                      shielded and located on a roof
 @         and storage areas are designed and          a)  located more than 2m from       deck and where appropriate the
           located to—                                     any property boundary:          basement of the building.
           a} = avoid adverse visual impacts when      b)  where located at ground
                viewed from the street and adjoining       level, screened by fencing             ;                                         {
                properties; and                            1.5m in height or dense
           b)   visually integrate with the building       vegetation of at least 1.5m in
                design.                                    width incorporating grouped
                                                           frees and shrubs with
                                                           maximum separation
                                                           distance of 1m measured
                                                           from the centre of the tree or                          .
                                                           scrub; and                                                    :
                                                       c)  are visually integrated into
                                                           the line and plane of the
                                                           building and roof design and
                                                           do not project beyond the           .
                                                           height or width of the
                                                           building when viewed from
                                                           the street and adjoining
                                                           properties;
                                                       AND
                                                       $4.2 For Industrial business ond
  —                                                    Retail business Type 3, materials   N/A
 @                                                     stored outside of a building do
  :                                                    not exceed 4m in height or half
                                                       the height of the on-site buildings
                                                       whichever is the greater.
 .         Safety and security                                     ;      .                            .
                                  :                    $5.1 Boundaries are identified by   Complles - site boundaries will be
           O5 All property boundaries are clearly      such means as - fencing: or        clearly identifiable, yet will maintain
           identifiable with public and private spaces | Changes in surface materials or  a certain level of permeability
           clearly defined.                            levels; or landscape treatments.    towards Hastings street with the use
                                                                                          of transparent shop fronts.

           06 All premises and access routes are
           clearly identifiable to all persons,        $6.1 All premises are identified by | Complies - A street number will be
           particularly emergency services personnel. | the provision of the street number | clearly identifiable from the
                                                       in a prominent location,            Hastings Street frontage.
                                                       preferably near the site entry. {i.e.
                                                       on the kerb or letterbox or by
                                                       signage on the building or site}.
           07 All building entries are designed fo be                                                            .
           obvious and easily identifiable.            $7.1 The number of entrances and | Complies - The main entrances to       :
                                                       exits are limited and main building | the building are visible at a street
                                                       entrances/exits are located at the | level on Hastings Street. Separate
                                                       front of the site, in view of the  entrances are proposed for the
                                                       street. Where this is not possible, residentiat and business

           June 2007                 Material Change of Use for Retail Business Type 2 Shop & Salon and          Page 26 of 33
                                               Visitor Accommodation Type 4 Conventional
                                                    33 Hastings Street, Noosa Heads

Used in these records

About this file

File size
12.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

00156B56.001.pdf · 12.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.